MIDI Data Format181 01V96i—Reference Manual Appendix: MIDI2.8.3.1.5 Parameter Address Consult your dealer for parameter address details. 2.8.3.2 Parameter change (Edit buffer) 2.8.3.3 Parameter request (Edit buffer) 2.8.3.4 Parameter change (Patch data) 2.8.3.5 Parameter request (Patch data) 2.8.3.6 Parameter change (Setup memory)2.8.3.7 Parameter request (Setup memory) 2.8.3.8 Parameter change (Backup memory) 2.8.3.9 Parameter request (Backup memory) 2.8.3.10 Parameter change (Function call: Library store / recall) Reception When this is received, the specified memory/library will be stored/recalled. If this is received from Studio Manager or Cascade Link, the operation will be ex- ecuted, and then the result of execution will be transmitted as a Parameter Re- sponse. Transmission If [Parameter change Tx] is ON, and you store or recall a memory/library for which Program Change transmission is not valid, this message will be transmit- ted with the Device Number set to the [Tx CH]. STATUS 11110000 F0 System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00000001 01Edit Buffer 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. DATA 0ddddddd dddata :: EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00000001 01Edit Buffer 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00000010 02Patch data 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. DATA 0ddddddd dddata :: EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00000010 02Patch data 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00000011 03Setup data 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. DATA 0ddddddd dddata :: EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00000011 03Setup data 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00000100 04Backup data 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. DATA 0ddddddd dddata :: EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00000100 04Backup data 0eeeeeee eeElement no. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp ppParameter no. 0ccccccc ccChannel no. EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010000 10Function call 00ffffff fffunction 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low DATA 0ccccccc chchannel High 0ccccccc clchannel Low EOX 11110111 F7End of exclusive
182Appendix: MIDI 01V96i—Reference Manual *1) 0:CH1 – 31:CH32, 32:ST-IN1L - 39:ST-IN4R, 128:BUS1 – 135:BUS8, 256:AUX1 – 263:AUX8, 512:STEREO Use 256 if the recall destination or store source is a single data item. Effect is 0:Effect 1–3:Effect 4 If the store destination is 16383 (0x3FFF), this indicates that the li- brary data has been changed by a external cause (such as bulk re- ception) (only transmitted by the 01V96i) *2) Varies with the firmware version. 2.8.3.11 Parameter change (Function call: title) Reception When this is received, the title of the specified memory/library will be changed. If this is received from Studio Manager or Cascade Link, the operation will be executed, and then the result of execution will be transmitted as a parameter re- sponse. Transmission In response to a request, this is transmitted with the device number set to the [Tx CH]. When the title is changed on the 01V96i, this message will be transmitted with the device number set to [Tx CH]. *1) Varies with the firmware version. 2.8.3.12 Parameter request (Function call: title) Reception When this is received, a parameter change will be transmitted with the device number set to [Rx CH]. Refer to the above table for the Functions and Numbers. 2.8.3.13 Parameter change (Function call: Scene/Library Clear) Reception When this is received, the specified memory/library will be cleared. If this is re- ceived from Studio Manager or Cascade Link, the operation will be executed, and then the result of execution will be transmitted as a parameter response. Transmission When a memory or library is cleared on the 01V96i, this message will be trans- mitted with the device number set to [Tx CH]. *1) Varies with the firmware version. 2.8.3.14 Parameter change (Function call: attribute) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the attribute of the specified memory/library will be changed. Transmission In response to a request, a Parameter Change message will be transmitted on the [Rx CH]. If [Parameter change ECHO] is ON, this message will be retransmitted without change. 2.8.3.15 Parameter request (Function call: attribute) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, a Parameter Change message will be transmitted on the [Rx CH]. function number channel*1) tx/rx SCENE RECALL 0x00 0-99, 8192 256 tx/rx EQ LIB RECALL 0x01 1-200, 8192 0-513 tx/rx GATE LIB RECALL 0x02 1-128, 8192 0-95 tx/rx COMP LIB RECALL 0x03 1-128, 8192 0-513 tx/rx EFF LIB RECALL 0x04 1-128, 8192 0-3 tx/rx CHANNEL LIB RECALL 0x06 0-128, 8192 0-513 tx/rx INPATCH LIB RECALL 0x07 0-32, 8192 256 tx/rx OUTPATCH LIB RECALL 0x08 0-32, 8192 256 tx/rx SCENE STORE 0x20 1-99 256, 16383 tx/rx EQ LIB STORE 0x21 41-200 0-513, 16383 tx/rx GATE LIB STORE 0x22 5-128 0-31, 16383 tx/rx COMP LIB STORE 0x23 37-128 0-513, 16383 tx/rx EFF LIB STORE 0x24 xx(*2)-128 0-3, 16383 tx/rx CHANNEL LIB STORE 0x26 1-128 0-513, 16383 tx/rx INPATCH LIB STORE 0x27 1-32 256, 16383 tx/rx OUTPATCH LIB STORE 0x28 1-32 256, 16383 tx/rx STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010000 10Function call 0100ffff 4ftitle 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low DATA 0ddddddd ddtitle 1 ::: 0ddddddd ddtitle x(depend on the library) EOX 11110111 F7End of exclusive function number size SCENE LIB TITLE 0x40 0-99,256(0:response only) 16 EQ LIB TITLE 0x41 1-200(1-40:response only) 16 GATE LIB TITLE 0x42 1-128(1-4:response only) 16 COMP LIB TITLE 0x43 1-128(1-36:response only) 16 EFF LIB TITLE 0x44 1-128(1-xx(*1):response only) 16 CHANNEL LIB TITLE 0x46 0-128(0:response only) 16 INPATCH LIB TITLE 0x47 0-32(0:response only) 16 OUTPATCH LIB TITLE 0x48 0-32(0:response only) 16 STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010000 10Function call 0100ffff 4ftitle 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010000 10Function call 0110ffff 6fclear function 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low EOX 11110111 F7End of exclusive function number SCENE LIB CLEAR 0x60 1-99 EQ LIB CLEAR 0x61 41-200 GATE LIB CLEAR 0x62 5-128 COMP LIB CLEAR 0x63 37-128 EFF LIB CLEAR 0x64 xx-128 (*1) CHANNEL LIB CLEAR 0x66 1-128 INPATCH LIB CLEAR 0x67 1-32 OUTPATCH LIB CLEAR 0x68 1-32 STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010100 14Function call 0000ffff 0fattribute 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low DATA 0ttttttt ttattribute(protect:0x0001, normal:0x0000) 0ttttttt tt EOX 11110111 F7End of exclusive function number SCENE LIB ATTRIBUTE 0x00 0-99(0:response only)
MIDI Data Format183 01V96i—Reference Manual Appendix: MIDIRefer to the above table for the Functions and Numbers. 2.8.3.16 Parameter change (Function call: link) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the patch link data of the specified scene will be modified. Transmission In response to a request, a Parameter Change message will be transmitted on the [Rx CH]. If [Parameter change ECHO] is ON, this message will be retransmitted without change. 2.8.3.17 Parameter request (Function call: link) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, a Parameter Change message will be transmitted on the [Rx CH]. Refer to the above table for the Functions and Numbers. 2.8.3.18 Parameter change (Function call: pair, copy) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, pairing will be enabled/disabled for the specified channel. *1) 0:CH1 – 31:CH32, 128:BUS1 – 135:BUS8, 256:AUX1 – 263:AUX8, 512:STEREO Effect is 0:Effect 1–3:Effect 4 In the case of PAIR, you must specify channels for which pairing is pos- sible. In the case of PAIR ON with COPY, you must specify Source Channel as the copy source, and Destination Channel as the copy destination. 2.8.3.19 Parameter change (Function call Event: Effect ) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the corresponding effect’s function activates (depending on the effect type). This does not activate when the effect type is different. 2.8.3.20 Parameter change (Sort Table) When scene memory sort is executed on the 01V96i, the memory sort table will be transmitted to Studio Manager. Studio Manager will sort the memories according to this data. If Studio Manager performs a scene memory sort, it will transmit this data to the 01V96i. 8-7 conversion is performed on the data area in the same way as for bulk. STATUS 11110000 F0 System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010100 14Function call 0000ffff 0fattribute 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010100 14Function call 0010ffff 2flink 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low DATA 0iiiiiii ihinpatch 0iiiiiii il 0ooooooo ohoutpatch 0ooooooo ol EOX 11110111 F7End of exclusive function number SCENE LIB LINK 0x20 0-99(0:response only) STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010100 14Function call 0010ffff 2flink 0mmmmmmm mhnumber High 0mmmmmmm mlnumber Low EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010001 11Function call Pair 0000ffff 0ffunction 0sssssss shSource channel H 0sssssss slSource channel L DATA 0ddddddd dhDestination channel H 0ddddddd dlDestination channel L EOX 11110111 F7End of exclusive function channel PAIR ON with COPY 0x00 *1) PAIR ON with RESET BOTH 0x01 *1) PA I R O F F 0 x 0 2 * 1 ) STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 01111111 7FUniversal ADDRESS 00010010 12Function call Effect Event 0000ffff 0ffunction 00000000 00 0ppppppp ppRelease:0, Press:1 DATA 00000000 00 0eeeeeee eeEffect number (0:Effect1 - 3:Effect4) EOX 11110111 F7End of exclusive function channel Freeze Play button 0x00 0:Effect1-3:Effect4 Freeze Record button 0x01 0:Effect1-3:Effect4 STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00010011 13Library sort table 0000ffff 0fLibrary type DATA 0ddddddd dsData :: 0ddddddd deData EOX 11110111 F7End of exclusive
184Appendix: MIDI 01V96i—Reference Manual 2.8.3.21 Parameter request (Sort Table) When the 01V96i receives this data, it will transmit Sort Table Data. 2.8.3.22 Parameter change (Key remote) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the same processing that is executed when the key spec- ified by Address is pressed (released). Transmission If [Parameter Change ECHO] is ON, this message is retransmitted without change. 2.8.3.23 Parameter change (Remote Meter) When transmission is enabled by receiving a Request of Remote meter, the specified meter information is transmitted every 50 msec for 10 seconds. When you want to transmit meter information continuously, a Request must be trans- mitted continuously within every 10 seconds. Reception This is echoed if [Parameter change ECHO] is ON. Transmission When transmission has been enabled by a Request, the parameter specified by Address will be transmitted on the [Rx CH] channel at 50 msec intervals for a duration of 10 seconds. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed. If [Parameter Change ECHO] is ON, this message is retransmitted without change. * Meter data uses the unmodified DECAY value of the DSP. The inter- pretation of the data will depend on the parameter. 2.8.3.24 Parameter request (Remote Meter) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, data of the specified address is transmitted on the [Rx CH] at intervals of 50 msec as a rule (although this may not be the case if the port is being used by other communication), for a period of 10 seconds. If Address UL= 0x7F is received, transmission of all meter data will be halted immediately. (disable) Transmission If [Parameter Change ECHO] is ON, this message is retransmitted without change. 2.8.3.25 Parameter change (Remote Time Counter) When transmission is enabled by receiving a Request of Remote Time Counter, the Time Counter data is transmitted every 50 msec for 10 seconds. When you want to transmit Counter information continuously, a Request must be trans- mitted within every 10 seconds. Reception This is echoed if [Parameter change ECHO] is ON. Transmission When transmission is enabled by receiving a Request, the Time Counter infor- mation is transmitted on [RxCH] channel every 50 msec for 10 seconds. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed. If [Parameter Change ECHO] is ON, this message is retransmitted without change. 2.8.3.26 Parameter request (Remote Time Counter) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the Time Counter information is transmitted on the [Rx CH] channel every 50 msec for 10 seconds. When the second byte of Address is received on 0x7F, data transmission will be halted immediately. (disable) Transmission If [Parameter Change ECHO] is ON, this message is retransmitted without change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00010011 13Library sort table 0000ffff 0fLibrary type EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00100000 20Key remote 0kkkkkkk kkKey address H 0kkkkkkk kkKey address M 0kkkkkkk kkKey address L DATA 0ppppppp ppRelease:0, Press:1 EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00100001 21Remote meter 0mmmmmmm mmADDRESS UL 0mmmmmmm mmADDRESS LU 0mmmmmmm mmADDRESS LL DATA 0ddddddd ddData1 H 0ddddddd ddData1 L :: EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00100001 21Remote meter 0mmmmmmm mmADDRESS UL 0mmmmmmm mmADDRESS LU 0mmmmmmm mmADDRESS LL 0ccccccc chCount H 0ccccccc clCount L EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00100010 22Remote Time counter 0000tttt 0t0:Time code, 1:Measure.Beat.Clock 0ddddddd ddHour / Measure H 0ddddddd ddMinute / Measure L DATA 0ddddddd ddSecond / Beat 0ddddddd ddFrame / Clock EOX 11110111 F7End of exclusive STATUS 11110000 F0System exclusive message ID No. 01000011 43Manufacture’s ID number (YAMAHA) SUB STATUS 0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3EMODEL ID (digital mixer) MODEL ID 00011010 1A01V96i ADDRESS 00100010 22Remote Time counter 0ddddddd dd0:Transmission request, 0x7F:Transmission stop request EOX 11110111 F7End of exclusive
YAMAHA [Digital Mixing Console-Internal Parameters] Date: 26 Aug. 2011 Model: 01V96i MIDI Implementation ChartVersion: 1.0 Function... Transmitted Recognized Remarks Basic ChannelDefault Changed1–16 1–161–16 1–16Memorized ModeDefault Messages AlteredX X **************OMNI off/OMNI on X XMemorized Note NumberTrue VoiceX **************0–127 X VelocityNote On Note OffX XO OEffect Control AfterKey’s Ch’sX XX X Pitch Bend X X Control Change0-95,102-119 O O Assignable Prog Change :True#0–127 **************0–127 0–99Assignable System Exclusive O O *1 System Common:Song Pos :Song Sel :TuneX X XX X X System Real Time:Clock :CommandsX XO XEffect Control Aux Messages:Local ON/OFF :All Notes OFF :Active Sense :ResetX X X XX X O O NotesMTC quarter frame message is recognized. *1: Bulk Dump/Request, Parameter Change/Request, and MMC. For MIDI Remote, ALL messages can be transmitted. Mode 1: OMNI ON, POLY Mode 3: OMNI OFF, POLYMode 2: OMNI ON, MONO Mode 4: OMNI OFF, MONOO: Yes X: No