Page 151
“ADP” jack. When wired at the MDF the second pair of the telephone line cord/cable will activate this jack for any analog device function. This jack and wiring is completely independant of the key telephone operation and may be used for system resources or direct Central Office connections. Refer to the following diagram for modular jack locations: f-. ,,, Each key telephone has two modular jack connectors on the underside of the instrument. Both are located in a recessed connector...
Page 152
-. 3. Carefully connect the RS232C DB-9 male end of the inierface cable from the device to the “SMDR” RS232C DB-9 female connector located at the bottom edge toward the left of the Option Module. The SMDR serial port output is one way to the printer or other Call Accounting device. Note: the KSU end is considered DCE and printer is DTE. L DCE MALE DB-9 DESIGNATION FEMALE. DTE DB-25 ’ 1 DCD 8 2 TD 3 3 RD 2 2 4 DSR 20 iz bi 5 GND 7 5 6 DTR 6 $ 7 CTS 4 8 RTS 5 9 RI 22 The SMDR port baud...
Page 153
X-RATE). This port must also be set to automatically acc&t.Jncoming Caller ID data; set the Data Link programming parameter to “AUTO” to complete this programming requirement. (RESOURCE - DATA LINK). The cable from the 1480-00 to the DHS Remote Programming port should be conf@red as follows: MALE m-9 CONNECTION z; 6.13 External Paging Equipment (optional) Cd The system provides a one way paging output at the KSU fi-om the Option Module when instailed. An 1/8-&h phono jack labeled “53 EXT PAGE”...
Page 154
6.13.1 Install the external paging equipment as’fobvs: 1. 3 h. 3. 4. 5. 6. 7. 8. 9. 10. Cut a length of shielded cable to run fYom the amplifier to the KSU. Attach an eighth inch male phono plug to one end of the cable. Connect the other end of the cable to the amplifier high-impedance input according to the manufacturer’s instructions. Connect the paging speaker(s) to the amplifier using speaker cable. Plug in the amplifier’s AC power cord. DO NOT use the same AC outlet being used...
Page 155
6.14 External Music Source - Standard MOHIBGM Module The Basic KSU is shipped with the Standard MOH/BGM Module. This module is located on a stand-off post toward the upper right corner of the CPU Module when c1-I -: viewing the installed KSU. The module provides a l/S-inch phono jack labeled “JKI MOH JACK” for direct connection to an external radio tuner, CD/tape player or other music source. The system music input impedance is 20K ohms. A trim POT (potentiometer) is also provided on the Standard...
Page 156
OR: if the music source has an earphone jack attach another l/S-inch phono plug (or other specified connector) to the other end of the cable, and plug it into the earphone jack on the music source. 3. Plug in the AC power cord for the music source. If possible. use a separate AC outlet than the one being used for the KSU. Turn on the AC power to the music source. . 4. Insert the l/S-inch phono plug into the appropriate music source jack inside of the KSU. 5. Since the “MOH” music source serves to...
Page 157
microphone voltage and allow the user to override the key.Jelephone MUTE operation. In this. case the headset adapter Mute finction must be used. (See headset manufacturer’s instructions for more details.) 6.17 Battery Back-up In the event of commercial AC power outage, the system can maintain full operation if battery backup is used. When Battery back is required, the Starplus Battery Back up Unit is used. Follow the instructions supplied with the BBU to install batteries in that unit. Refer the...
Page 158
6.18 Loud Bell Control (optional) When the Option Module is installed the system provides a dry contact closure to signal externallv nowered alerting devices for any incoming CO Line call. Transferred CO Lines that recall system wide‘ will also activate the LBC, in the same cadence as for an incoming CO Line ring. Installation 1. Determine which CO lines should operate the Loud Bell Control (LBC) relay. Program & of these lines separately for LOUD BELL = Y. See CO LINE PROGRAMMING 1 Battery I...
Page 159
. . 6.19 2 Port SLT Adapter The 2-Port SLT Adapter is used to connect analog single line telephones (SLT) and other analog devices to the system. The analog device must provide DTMF (touch tone) signals in order to make intercom calls, access outside lines and to activate system features. Some examples of analog devices are; telephone answering device (TAD), facsimile machine (FAX) or modem. Note: The 2-Port SLT Adapter is not an OPX device as determined by FCC Rules. The 2-Port SLT Adapter is...
Page 160
6.20 2-Port SLT Expansion: The ‘-Port SLT Expansion is a single PCB identical to the PCB of the 2-Port SLT Adapter. One 2-Port SLT Expansion may be housed in the 2-Port SLT Adapter enclosure. The expansion is shipped with screws used to secure it to the existing 2-Port SLT Adapter PCB stand-offs. Since the PCB and circuit function are identical to the 2-Port SLT Adapter, follow the installation wiring instructions provided above for the 2- Port SLT Adapter. To install the 2-Port SLT Expansion into...