Page 181

7.5.4.19 ‘Unsupervised Conference 
Description: 
Station users may leave two CO line connected parties in conference unsupervised. That is, the 
station user does not have to remain connected to the CO lines to maintain the conference 
connection. This setting allows or disallows this function. 
Range : Y/N 
Default : Y 
7.5.4.20 Auto Busy Redial 
Description: 
The Auto Busy Redial function will attempt to Redial a busy number for a preset number of 
attempts. Three data fields are programmed for ABR...

Page 182

7.5.4.21 Call Abandon Time 
Description: 
Call Abandon Time is set for two modes ACTIVE CALL and HELD CALL. This time 
represents the minimum interruption in loop current during these modes of operation that must 
be detected to force a CO line on-hook. Any CO line marked Call Abandon ‘9”’ will follow the 
associated timer programming. 
7.5.4.22 Ring Alternate Position 
Description: Range : ACTIVE CALL 50 - 2500 milliseconds 
HELD CALL 50 - 2500 milliseconds 
Default : ACTIVE CALL 600 milliseconds 
HELD...

Page 183

7.5.4.24 ‘Wait - ICLID 
Description: 
When Caller ID is equipped on the telephone company CO line, caller ID data is sent to the 
receiving party and equipment after the first ring signal and before the second ring signal. Since 
there is ‘some tolerance in the time that is required to receive the signal, the DHS may be 
programmed to send ringing to programmed DHS telephones more quickly when caller-ID data 
is received quickly. The DHS may also be programmed to wait longer for caller ID data in 
cases...

Page 184

7.5.5.2 Letter Type 
Description: 
The displayed characters for the messaging 
features and the Name in Display feature can be 
adjusted to accommodate special character 
requirements. When programming display 
messages the digit “1” dial pad key is pressed to 
insert special characters. One of six possible 
Letter Types may be selected for use when dial 
pad key “1” is pressed multiple times. Use the 
chart at the right to determine which Lettering 
Type Scheme is desired for this installation. 
While...

Page 185

7.5.5.6 Nite Start 
Description: 
The system may be set to operate in Time mode which allows the system to automatically 
change Service Mode from Day to Night Mode and back again. This time can be set for one 
time each day. The Nite Start time will switch the system into Night Mode at the designated 
time. 
7.5.5.7 Nite End 
Description: 
Range : 0O:OO - 23-59 
Default : 17:OO 
Nite End works in conjunction with Nite Start. The Nite End time entry designates when the 
system is to begin Day Mode...

Page 186

7.55. 
I. 
1.. Used to display special characters from the six Letter Type 
schemes possible. Reference the Letter Type feature and 
I 
associated programming on page 177: 
M 
I N I 0 I 
T I U I v I 
l When pressed before any dial key is pressed the numeral of the 
dial key will be displayed in this character position. 
~ l When pressed after a letter has been selected for this character 
position, the selected letter is forced to lower case. 
(space) and moves to the next position 
Range : 7 characters...

Page 187

Range : Messages may be I6 characters or less. 
Default : OUTGOING messages; CALL OPERATOR, CALL HOME, CALL SCHOOL, 
VISITORS WAITING, URGENT COME SEE M. 
EXECUTIVE NOTIFY messages: OUT FOR LUNCH, BE BACK SOON, LEFT FOR THE DAK 
IN A MEETING, OUT OF OFFICE, ON VACATION 
7.5.5.12 System Speed Numbers 
Description: 
There are 80 System Speed Dial Numbers that can be programmed for access by stations 
according to COS assignments. Stations with COS O-5 can access all 80 System Speed Dial 
Numbers. Stations...

Page 188

7.5.5.14 CO Line Copy 
Description: 
CO Line Copy is provided to assist in programming multiple CO lines with the same data. 
Follow the displayed instructions to copy one CO line data fields to another. 
Range : N/A 
Default : N/A 
7.5.5.15 Station Copy 
Description: 
Station Copy is provided to assist in programming multiple stations with the same data. Follow 
the displayed instructions to copy one station’s data fields to another. 
Range : N/A 
Default : N/A 
7.5.5.16 Feature Button Copy...

Page 189

7.5.5.19 Data Link 
I. 
. . %. 
Description: 
The Data Link programmin, u option is not implemented at this time. This is a future CT1 
function. 
‘Range : 
Default : 
7.5.5.20 RMT X-RATE (Remote Terminal Transmission Rate) 
Description: 
When the Option Module is installed the DB-9 pin RS-232 port labeled “REMOTE 
PROGRAMMING” can be connected to a modem or directly to a Personal Computer to use 
the PC based Database Programming software. RMT X-RATE is the baud rate setting of this 
port. 
.  Range :...

Page 190

NOTE: Dial Tone Detect requires the Option Module to function. However, if CO dial tone is 
slow and dialed digits are being sent before CO dial tone is ready, the Dial Wait Time may be 
used to eliminate the problem by imposing a fixed wait period before digits are sent. 
7.5.5.24 Dial Wait Time 
Description: Range : Y/N 
Default : N 
Similar to the Dial Tone Detect feature, Dial Wait Time can be used to delay out dialing based 
on a timer instead of a Tone Detector for applications where the Option...