Page 181
7.5.4.19 ‘Unsupervised Conference Description: Station users may leave two CO line connected parties in conference unsupervised. That is, the station user does not have to remain connected to the CO lines to maintain the conference connection. This setting allows or disallows this function. Range : Y/N Default : Y 7.5.4.20 Auto Busy Redial Description: The Auto Busy Redial function will attempt to Redial a busy number for a preset number of attempts. Three data fields are programmed for ABR...
Page 182
7.5.4.21 Call Abandon Time Description: Call Abandon Time is set for two modes ACTIVE CALL and HELD CALL. This time represents the minimum interruption in loop current during these modes of operation that must be detected to force a CO line on-hook. Any CO line marked Call Abandon ‘9”’ will follow the associated timer programming. 7.5.4.22 Ring Alternate Position Description: Range : ACTIVE CALL 50 - 2500 milliseconds HELD CALL 50 - 2500 milliseconds Default : ACTIVE CALL 600 milliseconds HELD...
Page 183
7.5.4.24 ‘Wait - ICLID Description: When Caller ID is equipped on the telephone company CO line, caller ID data is sent to the receiving party and equipment after the first ring signal and before the second ring signal. Since there is ‘some tolerance in the time that is required to receive the signal, the DHS may be programmed to send ringing to programmed DHS telephones more quickly when caller-ID data is received quickly. The DHS may also be programmed to wait longer for caller ID data in cases...
Page 184
7.5.5.2 Letter Type Description: The displayed characters for the messaging features and the Name in Display feature can be adjusted to accommodate special character requirements. When programming display messages the digit “1” dial pad key is pressed to insert special characters. One of six possible Letter Types may be selected for use when dial pad key “1” is pressed multiple times. Use the chart at the right to determine which Lettering Type Scheme is desired for this installation. While...
Page 185
7.5.5.6 Nite Start Description: The system may be set to operate in Time mode which allows the system to automatically change Service Mode from Day to Night Mode and back again. This time can be set for one time each day. The Nite Start time will switch the system into Night Mode at the designated time. 7.5.5.7 Nite End Description: Range : 0O:OO - 23-59 Default : 17:OO Nite End works in conjunction with Nite Start. The Nite End time entry designates when the system is to begin Day Mode...
Page 186
7.55. I. 1.. Used to display special characters from the six Letter Type schemes possible. Reference the Letter Type feature and I associated programming on page 177: M I N I 0 I T I U I v I l When pressed before any dial key is pressed the numeral of the dial key will be displayed in this character position. ~ l When pressed after a letter has been selected for this character position, the selected letter is forced to lower case. (space) and moves to the next position Range : 7 characters...
Page 187
Range : Messages may be I6 characters or less. Default : OUTGOING messages; CALL OPERATOR, CALL HOME, CALL SCHOOL, VISITORS WAITING, URGENT COME SEE M. EXECUTIVE NOTIFY messages: OUT FOR LUNCH, BE BACK SOON, LEFT FOR THE DAK IN A MEETING, OUT OF OFFICE, ON VACATION 7.5.5.12 System Speed Numbers Description: There are 80 System Speed Dial Numbers that can be programmed for access by stations according to COS assignments. Stations with COS O-5 can access all 80 System Speed Dial Numbers. Stations...
Page 188
7.5.5.14 CO Line Copy Description: CO Line Copy is provided to assist in programming multiple CO lines with the same data. Follow the displayed instructions to copy one CO line data fields to another. Range : N/A Default : N/A 7.5.5.15 Station Copy Description: Station Copy is provided to assist in programming multiple stations with the same data. Follow the displayed instructions to copy one station’s data fields to another. Range : N/A Default : N/A 7.5.5.16 Feature Button Copy...
Page 189
7.5.5.19 Data Link I. . . %. Description: The Data Link programmin, u option is not implemented at this time. This is a future CT1 function. ‘Range : Default : 7.5.5.20 RMT X-RATE (Remote Terminal Transmission Rate) Description: When the Option Module is installed the DB-9 pin RS-232 port labeled “REMOTE PROGRAMMING” can be connected to a modem or directly to a Personal Computer to use the PC based Database Programming software. RMT X-RATE is the baud rate setting of this port. . Range :...
Page 190
NOTE: Dial Tone Detect requires the Option Module to function. However, if CO dial tone is slow and dialed digits are being sent before CO dial tone is ready, the Dial Wait Time may be used to eliminate the problem by imposing a fixed wait period before digits are sent. 7.5.5.24 Dial Wait Time Description: Range : Y/N Default : N Similar to the Dial Tone Detect feature, Dial Wait Time can be used to delay out dialing based on a timer instead of a Tone Detector for applications where the Option...