Home > Vodavi > Communications System > Vodavi Starplus Dhs/dhs-e Technical Manual

Vodavi Starplus Dhs/dhs-e Technical Manual

Here you can view all the pages of manual Vodavi Starplus Dhs/dhs-e Technical Manual. The Vodavi manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 261

6-12Program Mode Entry
Figure 6-4: Database Programming Functions—Restriction and System Application
5. Restriction[show][hold]
COS 0: Y
back next chg
COS 1: N
back next chg
CO Call Discr
back next showDGT Interval ###
bksp show chg
0    
back next chg
     9
back next chg
Day Allowed
back next chg
Nite Allowed
back next chg
[show][hold]
[hold]
Group Member xx(xx)
(Repeats 24 times)
back next chg
6. System Application[show][hold]
Station Hunt Groups
back next showEnter Hunt Groups: #
bksp show chg
Group...

Page 262

Station Programming6-13
Station Programming
If the system is in the programming mode, continue using the [back] and [next] Soft 
Buttons to scroll to the desired programming field. If starting to program here, enter the 
programming mode. 
Refer to “Program Mode Entry”. Also refer to Table 6-1: Database Programming Table for 
the complete list of programmable features and their default values.
System Type 
The system may be programmed for compliance to the appropriate CO line access 
functionality...

Page 263

6-14Station Programming
Release feature. COS 0 is considered the highest level where COS 7 is the lowest. COS also 
dictates the stations ability to use System Speed Dial.
Default
DHS/DHS-E station Day Class of Service is set to [0], and the range is 0-7.
Related Programming
Refer to “Privacy Release”, “CO Call Discrimination”, and “System Speed Dialing”.
Night COS
Night COS specifically allows the programmer to assign a different mode of operation to 
any station for System Night Mode operation....

Page 264

Station Programming6-15
 
Default
DHS CO Lines (1-12) DAY ring for Station 10 only, all others are NONE, and DHS-E CO Lines 
(700-705) BOTH ring for Station 100 only, all others are NONE. DHS CO range is 1-12 (D/N/
B/NONE). DHS-E CO range is 700-717 (D/N/B/NONE).
Account Code Forced
Any station in the system may be forced to use an Account Code when outgoing calls are 
made. When this parameter is set to Y there must also be valid account codes 
programmed into the Account Code Table. The Account Code...

Page 265

6-16Station Programming
Drop Time-Out
Similar to Warning Tone above, Drop Time-Out may be applied to any station where 
outgoing call length is to be restricted. When set to Y this station will receive a warning 
tone over the connected voice path when the Warning Time (refer to Call Handling 
Configuration) has expired, and 10 sec later the current call will be terminated.
Default
DHS/DHS-E Drop Time-Out is set to N (NO) for all stations.
Related Programming
Refer to “Warning Time” in the Call Handling...

Page 266

CO Line Configuration6-17
CO Line Configuration
If the system is in the programming mode, continue using the [back] and [next] Soft 
Buttons to scroll to the desired programming field. If starting to program here, enter the 
programming mode. 
Refer to Program Mode Entry. Also, refer to Table 6-1: Database Programming Table for the 
complete list of programmable features and their default values.
CO Line Parameters
This section allows the programming of various CO Line Attributes so that the system 
may...

Page 267

6-18CO Line Configuration
CO Line Type Assignment
A CO Line Type is selected to identify specific CO lines. Type CO designates a typical CO 
line connection. Type PBX designates a CO line position that is connected to a PBX line 
(an extension off of another telephone system). This designation will cause system 
software to search the PBX code entry of digits dialed on a line marked PBX so that toll 
restriction may be applied following the PBX code. In addition, Last Number Redial, Auto 
Busy Redial and...

Page 268

CO Line Configuration6-19
Private To
Private To is a programming time saver. This parameter allows the programmer to assign 
a specific CO to one station for their personal exclusive use. This setting over-rides CO 
Line Assignment programming. When a station is assigned as the Private To station of a 
CO line, that station exclusively receives ringing and access privileges to that CO line.
Default
The DHS/DHS-E Private To is Empty (not assigned to any stations). The DHS Station range 
is from 10-81, and...

Page 269

6-20Call Handling Configuration
Call Handling Configuration
If the system is in the programming mode, continue using the [back] and [next] Soft 
Buttons to scroll to the desired programming field. If starting to program here, enter the 
programming mode. 
Refer to “Program Mode Entry”. Also, refer to Table 6-1: Database Programming Table for 
the complete list of programmable features and their default values.
Privacy Release
Privacy Release is a system wide setting that affects how the privacy feature...

Page 270

Call Handling Configuration6-21
Exclusive Hold Time
Calls placed on Exclusive Hold will remain on Exclusive Hold for the duration of this timer. 
When the timer expires the holding line will change from Exclusive Hold flash to Recall 
Flash and alert the station user with one tone ring over the telephone speaker. When the 
timer expires a second time and the CO line remains on hold the station will receive a 
second alert tone and the CO line holding condition will change to System Hold so that 
any...