    							STARPLUS 308EX ISSUE 2 JULY 1,1987 
    -500.18 SYSTEM 
    CONFIGURATION 
    (Data Field 21) 
    STA LED’s WIII be M rndcating current programming. 
    To change a feature, press appropriate STA button 
    so the LED lights or ext?i@%hes: 
    -$TA 10 -queuing -. -. r” :I! 
    STA 1 1 - hold preference 
    STA 12 - alarm detection . 
    ._ -6.0 ’ 
    k 
    II isi TA 
    ’ 13 - alarm signaling mode 
    TA 14 -automatic privacy 
    STA 15 - alarm enable 
    &@%TA 16 - background music 
    @ss HOLD button. Queuing 
    If this button is lit, queuing is allowed on a system 
    basis. Stations queurng a line are recalled accordrng 
    to line group queued. 
    4-+&d Pfekrence 
    The system may be programmed to have either 
    exclusive hold or system hold preferred. 
    If exclusive hold is preferred, depress HOLD button 
    once for exclusive hold and twice for exclusive 
    hold (when using the telephone). If system hold 
    IS 
    preferred, depress HOLD button once for system 
    hold and twice for exclusive hold. Transfer and 
    conference calls are always placed on exclusive 
    hold. 
    Alarm Detection 
    Determines type of alarm signal received. LED lit 
    means closed loop; unlit means open loop. 
    Alarm Signaling 
    Determines type of signaling received. 
    LED lit means continuous tone; unlit means single 
    tone. 
    A yes entry (LED’lit) means that privacy is : 
    automa!ically provided on all communications in the 
    system. To eliminate privacy, extinguish the LED. 
    Alarm Enable 
    A yes entry (LED lit) means the system is 
    programmed for alarm. Stations must then be 
    programmed to receive the alarm signal (Data Field 
    02). You must also choose alarm signalllng - STA 
    buttons 12 and 13. 
    Background Music 
    If a music source has been installed and background 
    music is desired, toggle this button ON so the LED 
    is lit. If this button is unlit, no background music 
    will be received through telephone speakers. 
    5-10  
    						
    							,’ 
    ,, 
    _’ 
    :: : 
    -- 
    -3 
    , 
    STARPLUS 308EX ISSUE 2 JULY 1,1987 
    5CIO.19 SYSTEM TlMERS (Data Fields 22-2s) 
    Exclusive Hold Recall (Data Field 22) 
    En?er data field and dial 3 digit number between 
    OCO and 255. 
    Press HOLD button. 
    System Hold Recall (Data Field 23) 
    Enter data field and dial 3 dIgIt number between 
    0008255. 
    Press HOLD button. 
    Transfer Recall (Data Field 24) 
    Enter data field and dial 3 drglt number between 
    0008255. 
    Press HOLD button. 
    Mzssage Waiting Reminder Tone (Data Field 25) 
    Enter data field and dial 3 digit number between 
    0008255. 
    Press HOLD button. 
    Pause Timer (Data Field 26) 
    Enter data fteld and dial 1 digit number between 
    1 and 9. 
    Press HOLD button. Reflects elapsed time before a CO line call placed on 
    exclusive hold will recall the initiating station. 
    If unanswered for the same elapsed time, it will recall 
    to the attendant and if unanswered by the attendant 
    will recall all phones in the system. 
    Default is 060 seconds. 
    ‘> 
    Reflects time elapsed before an unanswered 
    placed on system hold is recalled to the 
    initiated it. If unanswered for the same elap.sed ‘&II,. 
    it will recall to the attendant and If unanswered &, 
    the attendant will recall all phones In the systerrk 
    Default is 060 seconds. 
    Reflects the time elapsed before an unanswereg. 
    transfer is recalled to the statlon that Initiated it. 
    If unanswered for the same elapsed time. It w~ll~-ii 
    to the attendant and if unanswered by the at’tenoq 
    will recall all phones in the system. 
    Default is 030 seconds. 
    A statton with a message waiting can be remlndeg 
    at a timed interval with a tone. The tone WIII continue 
    until all messages have been answered. The int&%$ 
    can be programmed between 001 and 255 mr #%,. 
    By default the timer is disabled. ? 
    When dialing a speed number, a timed pause in @$ 
    sending can be inserted into the number. The le 9th 
    of the pause is controlled by the pause timer an ‘2 
    s 
    can be from 1 to 9 seconds. Default is 2 secon +-  CkD 
    _-, 
    5-l 1  
    						
    							STARPLUS 308EX -ps --a. ISSUE 2 JULY 1,1987 
    -..a 
    500.20 EXECU-MEISECRETARY 
    ASSJGN~IENTS (Data Field 27) 
     Upon entering program field, CO line 1 will be lit for 
    :i entering the first pair--- 
    , Press DSS button to assign executive. 
    (LED will light steady) 
    Press second DSS button to assign secretary. 
    ,(LED will flash) 
    Press HOLD button. 
    ‘CO line 2 will light for programming the second pair, 
    Ithen CO line 3 for the third pair and CO line 4 for 
    :the forth pair. 
    press HOLD after each pair entered. 
    To cancel an assignment, press CO line button of 
    tnat assignment and then press any DSS button 
    tvfice. -z 
    press HOLD button. 
    500.21 LOUD BELL CQNTROL (Data Field 28) 
    Er!:er data field and press station button of station 
    to be assigned ringing. (LED will Ilght) 
    Press HOLD button. 
    $00.22 PBX DIALING CODES (Data Field 30) 
    ;;Upon entering data field, CO line 1 will light for 
    programming, the first code number. 
    3 
    ‘Enter the 2 digit number on the dial pad, If the 
    -kmber is only 1 dlgit, enter the pound (4) as the 
    ‘sedond digit. 
    Press HOLD button. 
    .?ext CO iines will light for programming the other 
    ‘3 codes. 
    bJG0.23 AI-ENDANY POSiT1BN fDab Field 31) 
    Enter data field and press DSS station button of the 
    station that is to be the attendant. 
    Press HOLD button. There are 4 sets of Executive/Secretary pairs 
    available for assignment. When the Executive is busy 
    or in DND, intercom calls and transfers will be 
    automatically routed to the secretary(ies). 
    -One executive can go to 4 secretaries, 1 secretary 
    can answer for 4 executives, or 1 executive ‘can be 
    assigned 1 secretary. 
    One loud bell control is available and can be 
    assigned to any station. Loud Bell contacts will 
    follow the assigned ringiiig of that station. 
    None are assigned by default. 
    ^ _ 
    Four 2 digit PBX access codes can be entered in’ 
    system memory. When dialed, they sigr,al the 
    system that an access code is being dialed and tS; 
    toll restriction is to be applied at the next dialed 
    digit. Other	iise toll restriction does not apply. 
    This allows dialing of P5X extensions 100, 1 10, 
    111, etc. 
    A one digit code may be used. - - 
    One station must be assigned as the attendant for 
    line recalls and entering the system into night t 
    service. 
    Station 10 is assigned by default. 
    5-12  
    						
    							STARPLUS 308EX ISSUE 2 JULY 1,1987 _ 
    500.24 CALL FORWARD PRESET 
    (Data Fields 32 and 33) 
    Station Assignment (Data Field 33) 
    press DSS butt5 gsstation to be automatrcally 
    forwarded (LED lights steady). 
    Press DSS button of statron to receive the forwarded 
    call (LED flashes). 
    Make all entries desired. 
    Press HOLD button. 
    To remove a station for preset forward, 
    press that DSS button twice. 
    Preset Forward Ring Timer (Data Field 32) 
    Enter data field and dial 2 dlgrt number between 
    10 and 99. 
    ’ Press HOLD button. 
    500.25 CONFERENCE TIMER (Data Field 34) 
    Enter data field and dial 2 digit number between 
    00 and 99 
    Press HOLD button. Ringing CO lines can be forwarded to another 
    predetermined statton if the origrnal station is busy or 
    does not answer. These lines will ring for a 
    programmed period of trme before forwardrng 
    Durtng thus time the busy station will hear muted 
    ringing. 
    Determines the amount of time a call ~111 ring K&I@; 
    station before automatrcally forwardrng to the :- 
    predetermined statron. Default sets the timer at la 
    seconds. 
    Reflects amount of time the conference clrcurt w 
    tl !a 
    remain actrve if inrttator of the conference IS no .- -- 
    longer actively in the conference. A warnrng tone wil! 
    be presented to remainrng users 15 seco.nds prior@< 
    shutdown. Default is 15 mrnutes. , 
    - : 
    5-13  
    						
    							STARPLUS 308EX ISSUE 2 JULY l,lg87 
    ms9a-- 
    -. 
    e 
    -. 
    5QG.26 
    Use the 
    TOLL RESTRlCTl0N TAMES 
    (Data Fieids 41-44) 
    following DataFields to prograin toll tables: 
    .-- Toll-Allow Table A--Fietd 41 
    Toll Deny Table A 1 Field 42 
    Toll Allow Table B - Field 43 
    : Toil Deny Table B - Field 44 
    - Upon entering the data field, 
    STA button 10 will be lit. 
    - Dial the allow.‘deny number including ‘don’t cares’. 
    (8 digits maximum) 
    - Press HOLD for entering the data, 
    STA button 11 will then automatically light up. 
    - Enter the next allow/deny number, 
    -.When ail of the numbers needed have been 
    programmed and entered, either enter another 
    da!a field or leave the program mode. The ‘Allow/Deny tables are organized into two sets of 
    tables to allow the 308EX system to support 2 
    different toll plans at one installed site. Allow.Deny 
    Table A is checked whenever a station is assigned 
    Class of Service 2; and Allow.‘Deny Table B is 
    Checked whenever a station is assigned Class of 
    Service 3. 
    Each table may contain up to 16 numbers of up to 
    8 digits each. Any number of digits up to 8 
    maximum may be entered. Less than 8 digits may / 
    be entered. For example, the programmer needs ( 
    only to dial “0” and press HOLD to program operatq 
    restriction. 
    The following rules should be remembered when 
    setting up the Allow/Deny tables: t 
    : 
    1. If nothing is assigned in either the a1l.o~~ or 
    deny table, no restriction-i’s applied. 
    2. If entries are made in the allow table and only 
    there, then only the numbers in the table are 
    allowed. (Allow Only Restrictton) 
    3. If entries are made in the deny table and-only 
    there, then only the numbers In the table are ’ 
    denied. (Deny Only) 
    4. If there a-e entries in both tables. the allow 
    table is searched first, and if the dialed number 
    is found, it is allowed. If it is not found In the 
    allow, the deny table is searched. If the number 
    is found in the deny, it is denied; if it is not 
    found in either one, it is allowed. 
    5. Exchange Codes can be blocked by specific ..- 
    entries in the Deny lists or allowed by specific 
    entries in the Allow lists. 
    When a CO line is marked PBX&OS restrictions 
    apply to the station only if one of 4 PBX codes 
    are dialed first. 
    The Allow S Deny tables are reserved for COS 2 
    and 3 respectively. See Data Field 01 
    When the pound (Z) is used, it ente-rs a don’t 
    care character. This will allow or deny any drgit 
    O-9 in that location. 
    A CO line marked Toll Restriction Override is not 
    subject to restriction of COS 2, 3 or 4. 
    5-14  
    						
    							STARPLUS 308EX 
    ISSUE 2 JULY 1,1987 
    CO LINE BFaOGRAf’tVWNG 
    PROGRAM CODE LINE 1 UNE 2 LINE 3 DEFAULT 
    Line Group - 11 
    Group 1 
    Line Type 12 DSS 10 I co 
    Signal 
    12DSSll 
    Toll Override 12 DSS 12 
    Private Line 12 DSS 13 
    Day Ring 
    13 
    Night Ring 
    14 
    Flash Timer 15 
    Ring Detect 16 
    Dial PI ke 17 DTMF 
    No 
    None 
    All Ring 
    Attefidan t 
    Ail Ring 
    Attendant 
    2 sec. 
    300 msec. 
    60 40 
    10 PPS 
    - 
    5-17  
    						
    							S-rAWPLUS 308EX 
    ISSUE 2 JULY 1, 1987 
    - 
    -v-w 
    PROGRAM CODE FEATURE FORMAT DEFAULT NEW I 
    I 21 DSS 10 - - CO Line Queuing Yes/No Yes 
    Hold Preference System/ 
    Exclusive System 
    t I , I 1 
    I I 21 DSS 12 ) Alarm Detection 1 Open/Closed 1 Closed 
    I 
    21 DSS 13 Alarm Signaling Continuous/ 
    Repeated Continuous 
    I I I I 
    I 
    21 DSS 14 Automatic Privacy 
    21 DSS 15 Alarm Enabie Yes/No 
    Yes/No Yes 
    -r. 
    - No I 
    21 DSS 16 Background Music Enable Yes/No NO 
    - 
    22 Exclusive Hold Recall 000-299 sec. 060 sec.. 
    23 System Hold Recall 000-299 sec. 060 sec. 
    c - 24 Transfer Reca!l 000-299 sec. 030 sec. 
    25 Message Reminder Tone 00-99 min 00 I 
    ,,, ’ 
    ; 26 Pause Timer l-9 sec. 2 sec. , 
    -t--- I I I 
    1 
    Executive/Secretary 4 Pairs 
    Sta #, Sta .f None 
    I I I 
    I - 
    1 Loud Bell Control 1 4 Sets, Sta f ( None 
    I 
    f I , 
    I I I 
    30 PBX Codes 4 Nos., 1 or 
    2 Digit None 
    1 
    1 Attendant Position I Sta 10 I 
    Rint Timer - Preset Fwd 
    Sta!ion - Preset Fwd 
    Conference Timer lo-99 sec. 
    Unhmited 
    Sta I?, Sta # 
    00-99 min 15 sec. 
    None 
    15mK I I 
    I 
    5-18  
    						
    							SYARPLUS 308EX tsSUE 2 JULY 1,1987 
    2:. 
    r 
    c; 
    3; 
    -$ 
    Programmed from attendant station. SYSTEM SPEED DIAL : : 
    Dig& 
    ,4 15 
      i 10, : 112 ‘3 
    / 16 7 /8 9 1 10 
    11 12 13 14 15 16 
    ! 
    I 
    --. 
    11 ! 
    : 
    12 I-- - 
    B 
    I 
    N 
    L 
    0 
    C 
    A 
    T 
    I 
    0 
    r4 
    s ! 13 :. 
    I I ! I 
    I ! 1 I 
    ,14 , ! 
    I I 
    I 
    ,15i j i : / I 
    I 
    I 16, I f 
    / 
    I 
    f 
    ,7 ! I 
    I 
    I ! 
    18 I 
    I I / 
    7-r 
    i j I . I I 
    ! 20 ! 
    I 1 
     21 I 
    I 
    ! 
    I I 1 
    j 22 
    I j I / I 
    1 
    i23 ; I I 
    I ! 
    pi- / I 
    I j 
    I 2.3 / 
    I 
    I i j I 
    I 
    - .- 5 I 1 
    2 IS I 
    i I I j 
    ; 27 I / 
    1 
    I ! 
    9 j ; / I 
    I .- 
    1 _ 1 
    i 29 
    I j 1 / j / C 
    :30 , 
    I 
    , I 
    I ! 
    I i 1 
    :-31 : : ; 
    I 1. I 
    I I 
    ,32 j. I 
    I 
    I 1 I / 
    I 
    ! 33 / 
    I 
    ! I 
    I 
    I j 
    1 34 I 
    I 
    1 ! I 
    .I I i 1 I 
    i35 / : ; ( I 
    1 I ! 
    j 36 , I 
    I 
    I I 
    37 , i I I 
    I I 
    I / 
    38 
    I 1 
    I 
    1 1 I 
    : 39 ! / 
    I I 
    i40, / ; I 
    1 ! 
    41 / I 
    / 
    42; 1 - 
    I 1 i 
    43 ; ! I 
    I ! 1) 
    44 I I 
    I 
    45 j 
    I 
    46 1 / 1 i 
    47 1 
    .481 / 1 
    ! 
    Iill I, ,,, . 49 
    5-19  
    						
    							STARPLUS 308EX ISSUE 2 JULY 1,1987 
    Cods 41 -Allow Tabla,;A 
    ; B:n 14 i 1 i / j 1 i 
    Bin 15 1 j i i j ! 
    Bin 16 I 
    1 21314 5 6 7 .8 
    In 1 
    I 
    , I 
    I 
    : Bin 2 I 
    I ( j 
    , Bin 3 
    ( I 
    Bin 4 / 
    : Bin 6 / 
    I I I I I I I 
    ).. pin 7 
    Bin 8 
    Gin 9 
    Bin 10 
    , 
    I Bii 1 1 
    t I I 
    I 
    Birl 12 ( I .I I I 
    I I 
    Bin 14 
    1 Bin 16 1 
    I I I I I I I I 
    Bin 1 ( 
    I 
    Bin 15 I 
    I 
    ! 0 I 
    I 
    Bin 16 
    /I 
    cock! 44-Dar PJ Tabla B - ‘a..- 
    1 2 314 5 617 8 
    Bin 1 
    I I  
    						
    							STARPLUS 308EX ISSUE 2 JULY I,1987 
    - -- 
    vm 
    600 FUNCTIONAL TEST PROCEDURES 
    This section describes the procedures that should 
    be followed during system start-up. The installer will 
    ._ also find these teststo be helpful in the event of 
    system malfunctionxnd trouble shooting, 
    System trouble-shooting will be confined to 
    replacement of key telephone sets and fuses. 
    600.01 F’RELIMINARY CHECKLIST 
    Before starting the functional test procedures it is 
    recommended that the following checklist be 
    completed. Thus is designed to save time and 
    600.2 KEY STATION TESTING 
    1. 
    2. possibly eliminate the need for more detailed 
    trouble shooting. 
    Check: 
    A) Station cables for proper connections and 
    polarity. 
    6) Central office line connections. 
    C) Earth ground connections. 
    D) AC power cable. 
    E) Music source connections (if provided.) 
    F) Alarm connections (if provided.) 
    I 
    OPERATIONAL TEST RESULT 
    Connect the modular cord 
    1.1 Tone is heard for a short time 
    to the instrument. 
    I from the speaker of the 
    instrument. All LED’s are 
    1 
    I momentarily illuminated. 
    1.2 No tone, no reaction. 
    Depress the ON’OFF 
    j 2.1 ON’OFF lamp lights. 
    button on the Instrument. 
    I 2.2 Associated statlon 
    I 
    j 2.3 DSS key Irghts. 
    No reactlon 
    I 
    3. Background music, 
    3.1 With the ins!rument in an idle 
    state. depress 8 on the 
    dal pad. 
    3.2 Adjust the voice volume knob 
    3.2.1 Volume is increased or 
    (closest to the user) 
    decreased, as desired. 
    of the instrument. 
    3.2.2 No reaction. 
    3.3 Press 8 again. 
    4. 
    Do Not Disturb 
    4.1 Depress the DND button. 
    NOTE: Telephone must 
    be on-hook. 
    4.2 Press the DND button again. 3.1 .l Background music is heard 
    3.1 .2 No reactton. 
    3.2.3 Low volume - BGM. 
    3.3 MUSIC is turned off, 
    4.1 .1 DND tamp is lit steady. 
    4.1.2 No reaction. 
    4.2.1 DND lamp goes out. -i 
    sa 
    PROCEDURE 
    1.1 Normal 
    1.2 Check statlon wiring. 
    2.1 Normal 
    2.2 Normal 
    2.3 Check the connections of 
    key board connector 
    “K” in the instrument. 
    3.1 Normal 
    3.1 .2 Check that instrument IS 
    in on-hook state. 
    Check the Music Source 
    connection at the KSU. 
    3.2.1 Normal 
    3.2.2 Check the volume connector 
    (VL2) (closest to line keys) 
    in the instrument. 
    3.2.3 Adjust BGM adj. located on 
    left side of KSU. 
    3.3 Normal 
    4.1 .I Normal 
    4.1.2 Check the connections of 
    key telephone. 
    4.1 .3 Verify station is allowed 
    DND tn data base. 
    4.2.1 Normal 
    - 
    6-l  
    						