    							STARPLUS 1224M KEY TELEPHONE SYSTEM 
    700.5 CO LINE FUNCTIONS TEST 
    OPERATIONAL TEST RESULT PROCEDURE 
    1. Outgoing calls 
    1 .I LM handset or press ON/ 1 .I .I The CO line LED is lit 1.1.1 Normai 
    OFF button & press CO steady. 
    line button. 1 .I .2 Station OF/OFF button 1.1.2 Normai 
    LED is lit steady. Ail 
    stations where DSS is 
    2. Incoming calls programmed to appear 
    ;nz steady. D&i tone is 
    1 .I .3 CO-LED is not lit. 
    1 .1.3 Check line access 
    pro ramming. 
    2.1 incoming CO ringing 
    2.2 Press flashing CO line 
    button. 1 .1.4 D&i tone is not heard. 1 .1.4 C Yl eck CO line connections 
    at RJ-21X on the KSU. 
    2.1 .I Co ringing is heard. 
    2.1.1 Normal 
    2.1.2 CO ringing is not heard 2.1.2 Check programmin for rfni 
    but that line is flashing. assignment (day/night . Chec 
    3 
    CO line connections at RJ-21 I 
    on the KSU. 
    2.1.3 CO line LED or loop 
    2.1.3 Nom-d 
    button LED is flashing at 
    36 ipm. 
    2.2 CO line LED or loop 2.2 Normal 
    3. Transferrin 
    8 a CO line call button is lit steady. 
    3.1 During a C line coversa- 3.1.1 The CO line is placed on 3.1.1 Normai 
    tion, press TRANSlQUE Exclusive Hoid automati- 
    and d&i station number Wliy. 
    to which CO line is to be 3.1.2 CO line LED is flashing 3.1.2 Normal 
    transferred or 
    l?l ress that at transferring station but 
    station’s DSS 
    utton. remains stead at ail 
    other stations L ving line 
    access. 
    3.1.3 At receiving phone, the 3.1.3 Normal 
    CO line or loop button 
    LED is flashing at 
    Exclusive Hoid. 
    3.1.4 Hang up after diaiing 3.1.4 Normai 
    station number or pressing 
    DSS button for unscreened 
    transfer; announce caii 
    to receMng station before 
    hanging up for screened 
    transfer. 
    3.1.5 Music-on-hoid is 
    transmitted to external CO 3.1.5 Normai, if provided. 
    line. 
    3.1.6 No Music-on-hold is 
    transmitted to external CO 3.1 .tnChs%sk music connections 
    . 
    line caller. 
    3.1 .;df;efvlusic-on-hoid 
    3.1.7 Adjust MOH adjustment on 
    left side of KSU. 
    -., 
    i 
    4 
    I 
    k 
    1 
    JULY 1969 7-5  
    						
    							l 
    a 
    STARPLUS 1224EX KEY TELEPHONE SYSTEM 
    700. INTERCOM STATION TESTING 
    OPERATIONAL TEST RESULT PROCEDURE . 
    3.2 At phone receivin 
    transfer, press fla 8 the 3.2.1 CO line LED is now 3.2.1 Normal 
    ing CO steady at ail phones in 
    line button or loop button. the system. 
    3.2.2 CO line call is not 
    tgnsfgred to desired 3.2.iN?eck if called station is In 
    . 
    . 
    4. Add-On Conference 
    4.1 During a CO line conver- 4.1 CO line is placed on 4.1 Normal 
    7zo; press the CONF Exclusive hold automati- 
    cally, receMng MOH tf 
    provided. 
    4.2 Press DSS button of 3rd 4.2 Ringing is heard. 4.2 NomA 
    party to be added to the 
    conversation. 
    4.3 When 3rd party answers, 4.3 All 3 rties are connected 4.3 Normal 
    initiator presses CONF toget er. CONFLEDat  r 
    button again. both internal stations is 
    lit. 
    4.4 Hang up handset at first 4.4 
    CONF LED will extinguish. 4.4 Normal 
    station to terminate 
    conference call. 
    5. Multi-line Conference 
    5.1 P$e an outgoing CO line 5.1 Ringing is heard 5.1 Normal 
    5.2 When party answers & is 5.2 Party B is 
    e! aced automa- 5.2 Normal 
    notifed of conference ticall on dusiveHoid, 
    request, initiator presses hea ry ng MOH if provided. 
    the CONF button. Initiator hears intercom 
    dial tone. 
    5.3 Initiator presses another 5.3 CONF LED islftsteady& 5.3 Normal 
    CO line button & makes I ringing is heard. 
    another outgoing call to 
    paw c. 
    5.4 Initiator presses CONF 
    button again. 
    5.4 All 3 partles are connected 
    5.4 Normal 
    and both CO line LEDs 
    are lit steady. CONF 
    6. Flash 
    6.1 When completing a CO 
    line conversation, press 
    the FLASH button. button LED is lit steady. 
    6.1 ,NNdCO dial tone is 
    . 6.1 Normal 
    .  
    						
    							STARPLUS 1224E)f KEY TELEPHONE SYSTEM 
    800.1 
    880 MAINTENANCE AND -JOUt3U3HOO’T’i~G 
    GENERAL INFORlUJATlON 
    This section provides common maintenance, 
    troubleshooting and repair instructions for the 
    STARPLUS Key Telephone System. It is advisable 
    to use the latest issue manual and supporting 
    documentation whenever possible. 
    The 1224 architecture is designed such that all 
    solid state circuitry is enclosed in the KSU. The 
    only modular or replaceable type printed circuit 
    boards located inside the KSU are the SIU and 
    BCU. Therefore unless installing or replacing 
    trlese boards, the KSU cover should not be 
    removed. 
    isolating problems in the replaceable units such as 
    the key telephones or any external devices re- 
    quires no special knowledge of solid state 
    electronics or micro-processor programming 
    techniques. The 1224 system requires no involved 
    or complicated mechanical procedures for instal- 
    lation or removal of peripherals. 
    800.2 PREVENTIVE MAINTENANCE 
    A regular preventive maintenance program is es- 
    sential to reduce the possibility of system failures. 
    General type servicing such as cleaning and ln- 
    specting should be done yearfy. if the KSU is lo- 
    cated in an area of humidity, dust, etc., servicing 
    should be done more frequently. Generai setvic- 
    ing should include: 
    . Hardware and cabling. Check for general 
    mechanical integrity, loose or broken 
    wires, plugs or connectors. Tighten or 
    repair as necessary. 
    . KSU. inspect air vents located in front and 
    on top of the KSU cabinet for unrestricted 
    air passage. 
    . MDF/cabling. Inspect the MDF for loose 
    wires, obstructions, dust and dirt. 
    800.3 TEST EQUIPMENT AND TOOLS 
    The foilowing test equipment and tools are neces- 
    sary in performing maintenance and repair on the 
    1224 system. 
    a vdtmeter 
    = DTMF/dial pulse hand held test 
    telephone 
    . standard telephone repairman’s hand 
    toois 
    600.4 SPARE PARTS 
    The troubleshooting and repair instructions are 
    based on the assumption that spare key 
    tezphones and KSU are available to the repair- 
    man, either on-site or at a central 
    wcrehouse/storeroom location. In addition, 
    spsre fuses, jacks, wire and terminal block 
    should be available. 
    800.5 FIELD SERVICE ENGINEER- 
    ING 
    Installation, troubleshooting and repair are 
    described In detali within this manual. However, 
    ffetd service type questions such as appiication 
    requirements and troubleshooting assistance 
    arise w&h require support. Such services are 
    avaitabie through STARPLUS field service. Cail 
    l-800-356-7279 (in Arizona call 9982299). 
    800.6 FAULT CLASSIFICATION 
    Reported problems come from a variety of 
    peopie under differing conditions, therefore all 
    troude reports should be thoroughly examined 
    so that the exact problem is understood. Do not 
    always suspect the 1224 equipment Be sure to 
    checx external Interface equipment such as the 
    MDF, interconnection points, cabling, central 
    office or programming. To help isolate a fault 
    from the reported description, the fdlowing in- 
    formation should be investigated to further 
    define the fault source. 
    A. Were any changes made recently to the cus- 
    tomer database assignments that could cause 
    the problem? 
    B. Were any changes made recently to cabiing 
    that could cause the problem? 
    d 
    JULY 1989 8-1  
    						
    							C. Is the trouble condition associated wfth one clr- 
    cuit, a particular section or sections of circuits (Le., 
    l CO lines, stations) or common to all circuits? 
    D. Is the trouble intermittent or continuous? 
    E. Could the trouble be caused by “cross 
    symptoms” such that 2 failures mask the 
    symptoms associated with a particular fault? 
    800.7 SYSTEM FAILURES 
    various problems will affect the entire system. 
    These are normally related to power failures, 
    central processor failures, or memory failures. 
    Where central processor or memory failures 
    occur, the KSU must be replaced. When loss of 
    power occurs, steps can be taken to localize the 
    problem. 
    800.8 POWER FAILURES 
    The loss of commercial power will shut the system 
    down unless external battery backup is provided. 
    This loss of power could come from tripped circuit 
    breakers, AC cords unplugged, or a fuse blown. 
    When a power failure occurs, working toward the 
    source, test for voltage. The power monitor LED 
    will remain lit when power is present Since the 
    processor or power failure will cause swftchover to 
    the power failure telephone, the LED should be 
    used to determine whether it Is a power failure or 
    processor failure. It can be seen through the bot- 
    tom air vents located on the front cover of the KSU. 
    800.9 KEY TELEPHONE FAILURES 
    The following statements should be considered 
    when isolating & categorizing key telephone 
    failures: 
    Is the reported fault: 
    . Present on one telephone only? Check 
    wiring, programming, telephone and KSU. 
    Move telephone to a good working posi- 
    tibn to eliminate possible telephone 
    failure. 
    . Common to station numbers in pairs (l-2, 
    34, 5-8, etc.)? Check wiring polarity & 
    KSU. All operatlonal features are controlled by 
    software and SP@MC database assignments. 
    Most features are provided exclusively by 
    software. However some require supporting 
    equipment. For this reason, database assign- 
    ments should be checked before corrective 
    maintenance Is performed. Also check for  . Common to all station numbers? Check 
    programming & KSU. 
    I  STARPLUS 12240< KEY TELEPHONE SYSTEM 
    l Associated wfth a key telephone that 
    was recently moved? Check wiring, 
    programming, telephone & KSU. 
    . Associated wfth programming changes 
    made recently? (Ringing, CO line ac- 
    cess, etc.) Check for proper & accurate 
    programming. 
    . Occurring intermittently? Set up a test 
    to duplicate the problem. 
    . Accompanying a software failure? Test 
    the feature operation, programming 81 
    KSU. 
    800.10 CO/PBX LINE FAILURES 
    Problems with CO/PBX lines can be isolated 
    and 
    categorized by the following statements: 
    Is the reported fauft: 
    . Present on one CO line only? Check 
    the affected line, wiring, plug connec- 
    tions & KSU. 
    . Common to 2 or more CO lines? 
    Check the lines, wiring & KSU. 
    . Associated with a key telephone? 
    Check programming, telephone & 
    KSU. 
    . Associated with signaling (DTMF, d&l 
    pulse)? Check programming, CO line 
    & KSU. 
    . Associated with CO incoming ringing? 
    Check programming & KSU. * 
    . Occurring intermittently? Set up test to 
    duplicate problem. Once the problem 
    can be duplicated, check program- 
    ming, telephone, CO line or KSU. 
    800.11 FEATURE OPERATION 
    FAILURES 
    JULY 1989 
    8-2  
    						
    							proper usage by the customer, as feature failures 
    are often the fault of the user. Features that use 
    supporting equipment could have faulty equip- 
    ment. This should be checked. 
    The following is a list of features that use addition- 
    al equipment: 
    Alarm - alarm system 
    Background Music - music source con- 
    nections 
    Battery Back-up - battery package & 
    charger 
    Loud Bell Control - external power source 
    & ringing,device 
    A-Lead - ancillary equipment 
    Power Failure Transfer - telephone wiring 
    External Paging - ampiiffer, speaker & 
    connections 
    POWER TEST 
    PROCEDURE 
    1. Inspect installation RESULT 
    1. CO line connected to proper RJPlX connector. 
    2. MDF cabling punched down correctly on 88Ml-50 block. 
    3. Extemai connections properly connected. 
    4. Music source wiring securely connected. 
    2. Plug in AC cord 1. Power LED on. 
    2. AC power input voltage 198-l 28 VAC. 
    3. MDF volta e for station. 
    VT(-) to DT 
    9 +) = 28 VDC + 15% 
    VR(-) to DR( +) = 28 VDC + 15% 
    3. Feature verification 1 Q System programming according to desired feature 
    operation. (section 888) 
    2. Features function as described. (section 299) 
    JULY 1989 8-3  
    						
    							STARPLUS 1224EX KEY TELEPHONE SYSTEM 
    l 
    - 
    FART NUMBERS FOR STARPLUS 1224u< I* 
    sP1200-00 
    SP1220-01 
    SP61630-00 
    SP61632-00 
    VC61101 
    sP61610-00 
    SP6161 O-44 
    SP6161 O-54 
    sP61610-60 
    SP61612-00 
    SP61612-44 
    SP61612-54 
    SP61612-60 
    SP61614-00 
    SP61614-44 
    SP61614-54 
    SP61614-60 
    SP6161644 
    SP241 O-00 
    SP241 O-44 
    SP241 O-54 
    SP241 O-60 
    SP1250-00 
    SP1252-00 
    SP2453-00 
    SP61664-01 
    SP61664-00 
    SP1260-00 
    SP61640-00 
    SP61640-44 
    SP61640-54 
    SP61640-60 
    sP61660-00 
    SP61660-44 
    SP61660-54 
    SP61660-60 
    SP61666-54 
    SP61666-60 
    P14108-54 
    P14108-60 
    SP61662-00 
    SP61668-00 
    SP1290-00 1224EX BASIC KSlJ 
    PROGRAM CARTRIDGE GENERIC 1 
    RCU KIT 
    SIU KIT 
    BATTERY BACKUP UNIT 
    BASIC KEY TELEPHONE-BLACK 
    BASIC KEY TELEPHONE-ASH 
    BASIC KEY TELEPHONE-GRAY 
    BASIC KEY TELEPHONE-BURGUNDY 
    ENHANCED KEY TELEPHONE-BLACK 
    ENHANCED KEY TELEPHONE-ASH 
    ENHANCED KEY TELEPHONE-GRAY 
    ENHANCED KEY TELEPHONE-BURGUNDY 
    EXECUTIVE KEY TELEPHONE-BLACK 
    EXECUTIVE KEY TELEPHONE-ASH 
    EXECUTIVE KEY TELEPHONE-GRAY 
    EXECUTIVE KEY TELEPHONE-BURGUNDY 
    PHONE BOX-ASH 
    DSS CONSOLE-BLACK 
    DSS CONSOLE-ASH 
    DSS CONSOLE-GRAY 
    DSS CONSOLE-BURGUNDY ~ 
    STARPLUS 1224EX INSTALLATION MANUAL 
    STARPLUS 1224 STATION USER GUIDE 
    STAqPLUS 1224/2448 All’ENDANT USER GUIDE 
    DIRECTORY SHEET FOR BASIC KEY TELEPHONE 
    BLANK DESIGNATION TABS FOR STARPLUS TELEPHONES 
    SP1224EX NUMBERED KEY DESIGNATION TABS 
    WALL MOUNT KIT-BLACK 
    WALL MOUNT KIT-ASH 
    WALL MOUNT KIT-GRAY 
    WALL MOUNT KIT-BURGUNDY 
    REPLACEMENT HANDSET-BLACK 
    REPLACEMENT HANDSET-ASH 
    REPLACEMENT HANDSET-GRAY 
    REPLACEMENT HANDSET-BURGUNDY 
    12 FOOT HANDSET CORD-GRAY 
    12 FOOT HANDSET CORD-BURGUNDY 
    25 FOOT HANDSET CORD-GRAY 
    25 FOOT HANDSET CORD-BURGUNDY 
    BUTTON CAPS (I RED, 9 CLEAR) 
    DIRECTORY WINDOW FOR BASIC KEY TELEPHONE 
    SPl224EX DEMO KIT 
    APPENDIX - A 
    JULY 1989  
    						