Page 51
INSTALLATION INSTRUCTIONS SECTION 300-020-200 JULY 1986 11) Use the INC switch to correct data in LED #2 display. 12) Depress the MOQ switch once. e LED #1 displays 6 (start). l LED #2 has no display. 13) Slide the STR switch to ON and then back to OFF. * LEDs go off. l Data is transferred to working memory and time keeping starts. NOTE: If LED #I is changed to QFF before STR is operated, existing data will not be changed regardless of adjustments made in previous steps. 08.30 Program...
Page 52
INSTALLATION INSTRUCTIONS SECTION 300-020-200 JULY1986 l Listen for the caller’s voice via the called EKT’s speaker after single tone signal. l Called station’s INT LED: l-called flash. p) Dial fl at calling station. 0 Tone signalling heard via the called sta- tion’s speaker. q) Adjust tone signalling volume with volume control on the right side of the EKT being tested. r) Depress the m key. I INT LED: l-use flash. Q SPKR & MIC LEDs: on steady. l Listen for intercom dial tone via the EKT...
Page 53
a) Lift the OPL telephone handset and listen for CO dial tone. b) Verify that the corresponding CO line LED lights on the system EKTs. c) Dial a test call from the OPL telephone. l Verify that a 2-way voice connection is established. d) Depress the corresponding line key on an EKT. 0 Verify that the privacy feature prevents access. e) Go on-hook at OPL telephone. f) Depress the OPL CO line key on an EKT and listen for CO dial tone. g) Dial a test call from the EKT. l Verify that a 2-way...
Page 54
INSTALLATION INSTRUCTIONS SECTION 300-020-200 JULY 1988 MM/DD/YY 01 10 HH:MM 00:01;13 00;02 02 14 HH:MM 00:02;30 00:04 03 11 HH:MM 00:03:36 00: 10 765432101234567 FIGURE 35 - SMDR PRINTOUT EXAMPLE (Incoming Call) i) Put the printer “on-line” (DTR signal “on”). 0 Call record is output. j) Make an incoming call to the system and delay answering it for several rings. k) Answer the call. I) Enter an account code as in step d. m) Hang up. 0 Call record is output to the printer in the format...
Page 55
SMQU or an external source may be used (see Paragraph 10.10). 10.20 External Paging Connections 10.21 Strata provides access to an exter- nal paging speaker. This speaker ,can also be used for background music if programmed. The connection is made via the EXP or 600 terminals on the HINU, and can be used in one of three ways: a) To operate a customer-provided speaker di- rectly via an internal 3-watt amplifier located on the HINU PCB (EXP terminal). b) If more than 3 watts are required, an...
Page 56
INSTALLATION INSTRUCTIONS SECTION 300-020-200 JULY 1986 is in progress. 10.67 To provide external BGM control, con- nect the BR terminals on the HINU to the con- trol terminals (mute, mike switch, etc.) on the amplifier (see Figure 37). FIGURE 37 EXTERNAL AMPLIFIER HOOK-UP 10.70 Volume Setting Sequence 10.71 Refer to Figure 36 and adjust the vol- ume for MOH, BGM and External Page in the sequence outlined in Paragraph 10.72. 10.72 Adjust the MOH level first using the following procedures:...
Page 57
INSTALLATION INSTRUCTIONS SECTION 300-020-200 JULY 1986 10.80 Night Relay Service 10.81 As an option, Strata can provide a dry contact for the purpose of controlling an external loud ringing bell (or similar device) or an answering machine when the system is in the “NITE” mode. 10.82 To provide this service, connect the external device to the NR contacts on the HINU (refer to Figure 36). IMPORTANT! The NR and BR relay contacts are rated at 24 VDC/l amp and are not intended to operate high...
Page 58
TOSHIBA SYSTEM PRACTlCES ELECTRONIC KEY TELEPHONE SYSTEM PROGRAMMING PROCEDURES SECTION 300-020-300 JULY 1986 PROGRA PROCE
Page 59
TOSHIBA SYSTEM PRACTlCES ELECTRONIC KEY TELEPHONE SYSTEM PROGRAMMING PROCEDURES SECTION 300-020-300 JULY 1986 strata XII, & xx, PARAGRAPH PROGRAMMING PROCEDURES TABLE of CONTENTS SUBJECT PAGE 01 02 02.00 02.10 02.20 02.30 02.40 02.50 02.60 02.70 02.80 02.90 03 03.00 FIGURE SUBJECT PAGE 1 1 O-key EKT Key Format ...................... . 3 2 EKT Key Patterns ......................... . 10 3 Feature Key Assignments ..................... . 11 4 Sample Printout of Programs 01 - 0#9...
Page 60
TOSHIBA SYSTEM PRACTICES PROGRAMMING PROCEDURES ELECTRONIC KEY TELEPHONE SYSTEM SECTION 300-020-300 JULY 1986 TABLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 45 PROGRAMMlNG PROCEDURES TABLE LIST TITLE PAGE Hold Recall Time Code ........................... 12 lnitialized Data ............................... 15 System Data Printout Selection Codes .......................