Page 11
GENERAL DESCRIPTION SECTION 300-020-l 00 JULY 1986 TABLE B STANDARD FEATURES (continued) STATION l Automatic Dialing-Station e Automatic Line Preference 0 Call Forward (Intercom) l Direct Station Selection (DSS Key) l Do Not Disturb l Do Not Disturb Override l DP/MF Mode Change (Tone Key) l Exclusive Hold l Executive Override (Break-In) l Forced Account Code l Handsfree Answerback 0 I-called Illumination e I-hold Illumination 0 l-use Illumination 0 Modular Handset and Line Cords l...
Page 12
GENERAL DESCRIPTION SECTION 300-020-l 00 JULY 1986 HKSU (Strata Xrr, & XX,) TOCO 4 Door Phone 2-PAIR I 25 CI 115VAC EXTERNAL SPEAKER FIGURE IQ - SYSTEM DIAGRAM 05.03 Each system is controlled by a micro- Figures 3 and 4 (Strata X/fe & XXe, processor, located (along with the system pro- respectively) show the locations of the various gram and data memories) on the HCAU/CAAU PCBs and power supply. All PCBs slide in from PCBs. A second microprocessor on the HCBU the front of the cabinet...
Page 13
GENERAL DESCRIPTION SECTION 300-020-l 00 JULY 1986 oar Phone/Monitor Station I I HKSU 1 EKT l---EC -- HCDU #l l-3 .* I 1 1 XP I I AD10 CONTRO- HCBU #l $ DATA , HbTU #4 10-12 -a I 4 1 HPSU DSS’wli CONSOLE I FiGURE 11 - Strata XIpe FUNCTIONAL BLOCK DIAGRAM functions are as follows: HPSU 8120: This is the system power sup- ply, which provides 24 VDC operating volt- age for Strata X/la and connects to a 117 VAC, 60-Hz wall outlet. HPSU 9120: This power supply provides the 24 VDC...
Page 14
GENERAL DESCRIPTION SECTION 300-020-l 00 JULY 1986 oar Phone/Monitor Station El HOLB HCOU #l l-3 t 1 HCOU #7 19-21 HPSU I 9120 1 +24V I-1 1 CO/PBX LINES AC 115V FIGURE 12 - Strata Xx,FUNCTlONAL BLOCK DIAGRAM HCOU: An interface between the HKSU and would usually serve these lines. Central Office or PBX lines. Ring detection, hold and dial outpulsing are performed by HSTU/STAU: An interface between the this PCB. Depending upon local CO require- HKSU and EKTs, which includes the sys-...
Page 15
GENEWAL DESCRIPTIBN SECTION 300-020-l 00 JULY 1986 . corn paths for those eight stations. HCAU/CAAU: The CAAU is required and mounts directly on the HCAU to form a sin- gle unit. All system control functions are performed by the single-chip microprocessor located on the HCAU. The system program stored in ROM, the RAM for system opera- tions and the battery-protected RAM for system data storage are located on the CAAU. HCBU: Contains a microprocessor and serves to off-load the main CPU by...
Page 16
GENERAL DESCRIPTION SECTION 300-020-l 00 JULY 1986 FIGURE 14 - 20-key EKT 06.23 The lo-key Busy Lamp Field (BLF) EKT (Figure 15) with speakerphone may be as- signed at any one of up to 16 positions (sta- tions 10 - 25 only), and will indicate which of those stations are in a busy or DND condition. FIGURE 15 - IO-key BLF EKT 06.24 A 20-key Liquid Crystal Display (LCD) EKT (Figure 16) with speakerphone may be located at any or all stations in either system. The 32-character alphanumeric...
Page 17
GENERAL DESCRIPBIDM SECTION 300-020-l 00 JULY 1986 FIGURE 17 - DOOR PHONE FIGURE 18 - DSS CONSOLE 06.29 In the Strata X& only, one or two DSS consoles may be optionally added as BLF consoles. Their only function is to provide station status information using the LEDs. The DSS keys do not function when the DSS con- sole is used as a BLF console. 06.30 Installation 06.31 The Strata HKSUs are arranged at the factory for table-top mounting, but can also be wall mounted. 06.32 All connections...
Page 18
GENERAL DESCRIPTION SECTION 300-020-100 JULY1986 Tables B and C and some associated operating instructions. Detailed operating instructions can be found in the Strata X/l= & XX& EKT USER GUIDE or the installation and Maintenance manual (Section 300-020-400, Operating Procedures). 07.10 Standard Features 07.11 System AH Call Voice Page: Dialing a 2-digit access code permits a station user to page via all EKT speakers simultaneously. The system C?T: also be programmed to include the External...
Page 19
CO/PBX or feature keys. Flexible Line Ringing Assignment: A pro- grammable ring or no ring option is provided for each line selectively by each station. Each line may be programmed to ring a maximum of eight stations. Group Paging: Special 2-digit access codes (81, 82, 83 or 84) permit voice paging to one of four zones. Zone assignment is via soft- ware and is totally flexible. Paging is via the speakers of idle EKTs. Live System Programming: Live system pro- gramming is accomplished without...
Page 20
GENERALDESCRIPTION SECTIDN 300-020-100 JULY1986 strap remains intact, the relay is operated continuously when the system is in night service. This mode is intended for indirect control of an answering machine. 2) Night Bell Control: If the strap is cut, the relay pulses at a 1 -second on/3-sec- onds off rate whenever the system is in night transfer mode and an incoming call is ringing the system. This mode is in- tended to be used for indirect control of an external night bell. Repeat Last...