PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 10 PROGRAM 06 AUTOMATIC RELEASE ON HOLD ENABLE SET LED on. 1) Lock in the SET switch on the HKSU . Station 17 REP LED on. System is in program mode. 2) Depress them key on station 17. 3) Dial 1 tj] on the dial pad. 4) Refer to the System Record Sheet. Using the m keys, turn the associated LEDs on or off, as required. Each CO key/LED represents itself-that is, if CO 1 LED is on, CO 1 will have AROH during normal opera- tion. If CO 1 LED is off, AROH will not function on that line. 5) Depress the m key to place new data in memory. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs go on according to present data. An X on the record sheet means the LED should be on. If the LED is already on, depressing the asso- ciated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. All station 17 LEDs(except REP)gooff. 6A) Return to Step 2 in order to continue with this program . ..or... 6B) Go to Step 2 in another program table . . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. -23-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 11 PROGRAM 07 AUTOMATIC RELEASE ON HOLD (AROH) TIMING SET LED on. 1) Lock in the SET switch on the HKSU Station 17 REP LED on. System is in program mode. 2) Depress the m key on station 17. 3) Dial D 0 on the dial pad. 4) Refer to the System Record Sheet. Using the [r9 keys, turn the associated LEDs on or off, as required. Each CO key/LED represents itself-that is, if CO 1 LED is on, CO -1 will have XB (crossbar) timing for AROH. If CO 1 LED is off, ESS timing will be used on that line. 5) Depress the m key to place new data in memory. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs go on according to present data. An Xon the record sheet means the LED should be on. If the LED is already on, depressing the asso- ciated key will turn it off and vice versa. LEDs may be turned off and on until the desired pattern is set. All station 17 LEDs (except REP) go off. 6A) Return to Step 2 in order to continue with this program , ._ 6B) Go to Step 2 in aonbther program table . . . or . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. NOTE. This program will have no meaning unless AROH is enabled via Program 06. 1 -24-
PROGRAlUlUlING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 12 PROGRAM 0#8 NIGHT RING OVER EXTERNAL PAGE SET LED on. 1) Lock in the SET switch on the HKSU. Station 17 REP LED on. System is in program mode. key on station 17. 3) Dial B fl 1 on the dial pad. 4) Refer to the System Record Sheet. This program assigns either Ring or No Rin for each CO line in night operation. Using the b l keys, turn the associated LEDs on or off, as required. Each CO key/LED represents itself- that is, if CO1 LED is on, when the system is in night operation, incoming calls over that CO iine will ring over the external page; if CO1 LED is off, incoming calls over that CO line will not ring in night operation. 5) Depress them key to place new data in memory. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs go on according to present data. An X on the record sheet means the LED should be on. If the LED is already on, depressing the as- sociated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. Initialized Data: All LEDs on. . All station 17 LEDs (except REP) go off. 6A) Return to Step 2 in order to continue with this program or . . . 66) Go to Step 2 in another program table . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. NOTE. Use this program only if CO2 LED is on in Program 02. -25-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1966 TABLE 13 PROGRAM 09 SINGLE CO LINE (DIAL 9) GROUP SELECTION SET LED on. 1) Lock in the SET switch on the HKSU. Station 17 REP LED on. System is in program mode. Normal functions halt on station 17. m SPKR LED steady on. 2) Depress the l 3) Dial fl g on the dial pad. SPKR LED flashes continuously. CO LEDs go on according to present data. 4) Refer to the System Record Sheet. An X on the record sheet means the LED should Using them keys, turn the associated LEDs be on. on or off, as required. Each CO key/LED If the LED is already on, depressing the as- represents itself-that is, if CO1 LED is on, CO ociated key will turn it off and vice versa. LEDs 1 will be included in the “Dial 9” group for may be turned off and on until the desired pat- random selection by a single line (OPX) exten- tern is set. sion or by any station using Trunk Queuing. If CO1 LED is off, CO1 can be accessed onl b dialing 0 1 0 at the OPX station or by the &!I l key on an EKT. I 5) Depress them key to place new data in All station 17 LEDs (except REP) go off. memory. 6A) Return to Step 2 in order to continue with this program . . 66) Go to Step 2 in a%her program table . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. NOTE: Use this program only if the A06 LED is turned off in Program 0 1. -26-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 14 PROGRAM 09X FOUR CO LINE (DIAL 91,92,93,94) GROUP SELECTION SET LED on. 1) Lock in the SET switch on the HKSU. Station 17 REP LED on. System is in program mode. Normal functions halt on station 17. 2) Depress the m key on station 17. SPKR LED steady on. 3) Dial B u a on the dial pad. (X = 1, 2, 3 or 4 SPKR LED flashes continuously. de ending upon the group bein Al b defined). Dial for “dial 91” group; 1 1 CO LEDs go on according to present data. for “dial 92” group, etc. 4) Refer to the System Record Sheet. Using the m keys, turn the associated LEDs on or off, as required. Each CO key/LED represents itself-that is, if CO1 LED is on, CO 1 will be included in the “Dial 9X” group for random selection by a single line (OPX) exten- sion or by any station using Trunk Queuing. If CO1 LED is off, CO 1 can be accessed onl b dialing 0 B i at the OPX station or by the ti l An X on the record sheet means the LED should be on. If the LED is already on, depressing the as- sociated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. -7. key on an EKT. 5) Depress them key to place new data in memory. All station 17 LEDs (except REP) go off. 6A) Return to Step 2 in order to continue with this program 6B) Go to Step 2 in aonbther program table . . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. NOTE: Use this program only if the AD6 LED is turned on in Program 07. -27-
PROGRAMMlNG PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 15 PROGRAM Q#9 OPL LINE HUNTING SET LED on. 1) Lock in the SET switch on the HKSU. Station 17 REP LED on. System is in program mode. 2) Depress the m - key on station 17. 3) Dial 1 4 a on the dial pad. 4) Refer to the System Record Sheet. Using the m keys, turn the associated LEDs on or off, as required. Each CO key/LED represents itself-that is, if COs 1 & 2 LEDs are on, an incoming call at CO2 will ring the CO 1 OPL station if CO1 is idle. Lines must function in groups of three as they appear on the HOLB, and the lowest numbered line sncrsa be selected. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs qo on according to present data. An X on the record sheet means the LED should be on. If the LED is already on, depressing the as- sociated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. e 5) Depress the HOLD key to place new data in memory. All station 17 LEDs (except REP) go off. 6A) Return to Step 2 in order to continue with this program 6B) Go to Step 2 in a$her program table . . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. -28-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 16 PROGRAM 100 TOLL RESTRICTION SYSTEM PARAMETERS (DIALING PLAN) ’ 1 SET LED on. 1) Lock in the SET switch on the HKSU. I Station 17 REP LED on. System is in program mode. 2) Depress the mkey on station 17. Normal functions halt on station 17. SPKR LED steady on. 3) Dial 0 1 m on the dial pad. SPKR LED flashes continuously. CO LEDs go on according to present data. 4) Refer to the System Record Sheet. An X on the record sheet means the LED should Turn the associated LED on for the display plan be on. to be used. Only one LED may be on at one If the LED is already on, depressing the as- time. sociated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. 5) Depress them key to place new data in All station 17 LEDs (except REP) go’off. New memory. data is stored, previous data is erased. 6A) Go to Step 2 in another program table . . or . . . 66) Transfer data into working memory per SET LED goes off. Paragraph 02.06. Station 17, REP LED goes off. New data IS stored, previous data is erased. , -29-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 17 PROGRAM 101 TOLL RESTRICTION DISABLE SET LED on. 1) Lock in the SET switch on the HKSU. Station 17 REP LED on. System is in program mode. 2) Depress the m . key on station 17. 3) Dial 0 fl 0 on the dial pad. 4) Refer to the System Record Sheet. This program either enables or disables the toll restriction for each CO line in the system. Each CO key/LED represents itself--that is, if CO I LED is on, toll restriction is not applied to that CO line; if CO1 LED is off, toll restriction is applied to that CO line. 5) Depress them key to place new data in memory. Normal functions halt on station 17. SPKR LED steady on. SPKR LED flashes continuously. CO LEDs go on according to present data. An X on the record sheet means the LED should be on. If the LED is already on, depressing the as- sociated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. Initialized Data: All LEDs off. All station 17 LEDs (except REP) got off. _ 6A) Return to Step 2 in order to continue with this program 6B) Go to Step 2 in aonbther program table . . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. A -3o-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 . TABLE 18 PROGRAM 102 FORCED ACCOUNT CODE CHECK SET LED on. 1) Lock in the SET switch on the HKSU. / key on station 17. 2) Depress the l 3) Dial 0 1 a on the dial pad. 4) Refer to the System Record Sheet. This program determines whether Forced Account Codes will be checked on a CO-line- by-CO-line basis. Using themkeys, turn their associated LEDs on or off, as required. 0 LED on = Forced Account Codes are checked. l Each CO key/LED represents itself-that is, if the CO 1 LED is on, stations calling out over CO1 will be forced to enter an account code. 5) Depress them key to place new data in All station 17 LEDs (except REP) go off. memorv. 64 Return to Step 2 in order to continue with this program 56) 5C) Go to Step 2 i’n aE:ther program table . . .or.. . Transfer data into working memory per Paragraph 02.06. ‘VOTE: Program 0#2 defines account code digit length. Station 17 REP LED on. System is in program mode. Normal functions halt on station 17. SPKR LED steadv on. SPKR LED .flashes continuously. CO LEDs go on according to present data. An X on the record sheet means the LED should be on. If the LED is already on, depressing the as- sociated key will turn it off and vice versa. LEDs may be turned off and on until the desired pat- tern is set. Initialized Data: All LEDs off. . SET LED goes off. Station 17 REP LED goes off. New data is stored, previous data is erased. -31-
PROGRAMMING PROCEDURES SECTION 300-006-300 MAY 1986 TABLE 19 PROGRAM 103 EQUAL ACCESS #l 1 SET LED on. 1) Lock in the SET switch on the HKSU. I Station 17 REP LED on. System is in program mode. LEDs as shown below. Initialized Data: Blank (AD4 flashing). X = LED on All LEDs off = no data memory. New data is stored, previous data is erased. 6A) Return to Step 2 in order to continue with this program 6B) Go to Step 2 in azther program table . . or . . . 6C) Transfer data into working memory per Paragraph 02.06. SET LED goes off. Station 17 REP LED goes off. -32-