    							TABLE 29 
    PROGRAM 104/106 
    OTHER COMMON CARRIER AUTHORIZATION CODE LENGTHS #l and #2 
    1) Lock in the SET switch on the HKSU. 
    2) Depress the m key on station 13/l 7. 
    3) Dial 0 =I(0 11) n the dial pad. 
    4) Refer to the System Record Sheet. 
    This program definesthe lengthsof the autho- 
    rization codes for OCC #l & #2. These 2-digit 
    numbers are entered via the dial pad. SET LED on. 
    Station 13/17 LED 19 on. , 
    System is in program mode. 
    Normal functions halt on station 13/17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    The various LEDs indicate present data. 
    As each digit is entered, the entry is verified by 
    LEDs as shown below. 
    PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    Key/LED/ Start ) 1st Digit 
    2nd Diqit 
    Binary Numbers: 
    03 
    X = LED on 
    02 
    All LEDs off = no data 
    01 
    00 
    5) Depress the m key to place new data in 
    memory. 
    6A) Go to Step 2 in another program table 
    . . . or . . . 
    66) Transfer data into working memory per Par- 
    agraph 02.06. All station 13/l 7 LEDs (except 19) go off. 
    New data is stored, previous data is erased. 
    SET LED goes off. 
    Station 13/l 7 LED 19 aoes off 
    r(m rc. 
    rl”IL. 
    Program 106 follows the same procedure as Program 104. 
    Program 106 defines the length of OCC#2 authorization code.’ 
    -55-  
    						
    							TABLE 30 
    PROGRAM 108/l 09 
    TOLL RESTRICTION OVERRIDE CODES #l and #2  PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    1) Lock in the SET switch on the HKSU. 
    X = LED on 
    All LEDs off = no data 
    66) Transfer data into working memory per Par- 
    NOTE. 
    Program 5#W LED 13 enables stations to use Toll Restriction Qverride Codes 1 & 2. 
    -56-  
    						
    							TABLE 31 
    PROGRAM 1X0 
    TOLL RESTRICTION CLASS PARAMETERS 
    ( SET LED on. 
    1) Lock in the 
    SET switch on the HKSU. Station 13/17 LED 19 on. 
    System is in program mode. 
    2) Depress the m key on station 13/l 7. Normal functions halt on station 13/l 7. 
    SPKR LED steady on. 
    3) Dial aa 1 on the dial pad. 
    4) Refer to the System Record Sheet. 
    Using the various keys, turn their associated 
    LEDs on or off, as required. The detailed 
    meaning of each key/LED is shown below. 
    NOTE. 
    If any key/LED is not shown,.it is not used. SPKR LED flashes continuously. 
    An LED indicates present data. 
    An X on the record sheet means the LED shoulc 
    be on. 
    If the LED is already on, depressing the associatec 
    key will turn it off and vice versa. LEDs may be 
    turned off and on until the desired pattern is set. 
    PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    KEY/LED 
    LED ON LED OFF 
    02 
    Area code f 555 + XXXX-Allowed Not Allowed 
    01 
    01 or 01 1 Overseas Restricted Allowed 
    00 0 + Restricted Allowed 
    5) Depress the m key to place new data in 
    All station 13/l 7 LEDs (except 19) go off. 
    memory. 
    6A) Go.to Step 2 in another program table 
    . . . or . . . 
    66) Transfer data into working memory per Par- 
    agraph 02.06. 
    SET LED goes off. 
    Station 13/17 LED 19 goes off. 
    New data is stored, previous data is erased. 
    -57-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    TABLE 32 
    PROGRAM 1 XY 
    TOLL RESTRICTION CLASS AREA CODE ENTRY 
    (LCD TELEPHONE REQUIRED) 
    SET LED on. 
    1) Lock in the SET switch on the HKSU. Station 13/l 7 LED 19 on. 
    System is in program mode., 
    Normal functions halt on station 13/l 7. 
    LCD is blank. 
    2) Depress the m key on station 13/l 7. SPKR LED steady on. 
    3) Dia; 015 (Allow), iag(Deny) or flnl(Display) LCD is blank. 
    SPKR LED flashes continuously. 
    as required. (X = Restriction class 1 - 4.) LCD displays dialed number. 
    1 X 2 = LCD is blank. 
    4) Press /J key. 1 X 3 = LCD is blank. 
    1 X 4 = LCD displays all allowed codes. 
    5) Enter first area code in range sequence LCD displays code entered. 
    (start). 
    6) Depress 1 key.* LCD shifts left to provide space for next code. 
    7) Enter final area code in range sequence LCD displays code entered. 
    (stop).* 
    8) Depress 1 key. LCD is blank. 
    9) Return to Step 5 to enter additional area 
    codes. 
    10) Depress the m key to place new data in All station 13/17 LEDs (except 19) go off. 
    memory. 
    11A) Return to Step 2 in order to continue with 
    this program 
    . . . or . . . 
    116) Go to Step 2 in another program table 
    . . . or . . . 
    1 1 C) Tidnsfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 13/l 7 LED 19 goes off. 
    New data is stored, previous data is erased. 
    “Skip Steps 6 and 7 if only one.area code in sequence is being entered. 
    -58-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    TABLE 33 
    PROGRAM 1XZ 
    TOLL RESTRICTION CLASS OFFICE CODE ENTRY 
    (LCD TELEPHONE REdRED) 
    SET LED on. 
    1) Lock in the SET switch on the HKSU. Station 13/17 LED 19 on. 
    System is in program mode. 
    Normal functions halt on station 13/l 7. 
    LCD is blank. 
    2) Depress the m key on station 13/l 7. SPKR LED steady on. 
    LCD is blank. 
    3) Dial OUj (Allow), OIa(Deny) or ~~~(Display) SPKR LED flashes continuously. 
    as required. (X = Restriction class 1 - 4.) , 
    -- LCD disp!ays dialed number. 
    1 X 6 = LCD is blank. 
    4) Press g k‘ey. 1 X 7 = LCD is blank. 
    1 X 8 = LCD displays all allowed codes. 
    LCD displays code entered.  5) Enter first office code in range sequence 
    (start). 
    6) Deoress P kev:* 
    7) Enter final office code in range sequence 
    (stop).* 
    8) Depress 3 key. 
    9) Return to Step 5 to enter additional office 
    codes. 
    10) Depress the m key to place new data in 
    memory. 
    1 1A) Return to Step 2 in order to continue with 
    this program 
    . . . or . . . 
    116) Go to Step 2 in another program table 
    . . . or . . . 
    11C) Transfer data into working memory per 
    1 Paragraph 02.06. LCD shifts left to provide space for next code. 
    LCD displays code entered. 
    LCD is blank. 
    All station 13/l 7 LEDs (except 19) go off. 
    SET LED goes off. 
    Station 13/l 7 LED 19 goes off. 
    New data is stored, previous data is erased. 
    “Skip Steps 6 and 7 if only one office code in sequence is being entered. 
    -59-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    TABLE 34 
    PROGRAM 2XY 
    TOLL RESTRICTION AREA/OFFICE CODE EXCEPTION TABLE 
    (LCD TELEPHONE REQUIRED) 
    SET LED on. 
    1) Lock in the 
    SET switch on the HKSU. Station 13/l 7 LED 19 on. 
    System is in program mode. s 
    Normal functions halt on station 13/l 7. 
    LCD is blank. 
    2) Depress the m key on station 13/l 7. SPKR LED steady on. 
    LCD is blank. 
    3) Dial aafl (X 
    q Table 1 - 8). LCD displays dialed number, then shifts left to pro- 
    vide space for next entry (or displays current area 
    code). 
    4) Enter area code. 
    5) Depress them key. 
    6) Depress the m key. LCD clears and displays area code entered. 
    Binary data is shown on LEDs 00 - 03. 
    LCD is blank. 
    SPKR LED steady on. 
    LCD is blank. 
    7) Dial gaz (Allow), 311 (Deny) or gIa(Display) SPKR LED flashes continuously. 
    as required. (X = Restriction class 1 - 8.) LCD displays dialed number. 
    2 X 2 = LCD is blank. 
    8) Press 3 key. 2 X 3 = LCD is blank. 
    2 X 4 = LCD displays all allowed codes. 
    9) Enter first office code in range sequence LCD displays code entered. 
    (start). 
    10) Depress 1 key.” LCD shifts left to provide space for next code. 
    11) Enter final office code in range sequence LCD displays code entered. 
    (stop).” 
    12) Depress 3 key. LCD is blank. 
    13) Return to Step 5 to enter additional office 
    codes. 
    14) Depress the m key to place new data in All station 13/l 7 LBDs (except 19) go off. 
    memory. 
    15A) Return to Step 2 in order to continue with 
    this program 
    . . . 
    or . . . 
    15B) Go to Step 2 in another program table 
    . . . or . . . 
    15C) Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 13/17 LED 19 goes off. 
    New data is stored, previous data is erased. 
    “Skip Steps 10 and 11 if only one office code in sequence is being entered. 
    -6O-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    TABLE 35 
    PROGRAM 1X1 
    TOLL RESTRICTION CLASS AREA/OFFICE CODE EXCEPTION TABLE SELECTION 
    SET LED on. 
    1) Lock in the SET switch on the HKSU. Station 13/l 7 LED 19 on. 
    System is in program mode. ’ 
    Normal functions halt on station 13/17. 
    2) Depress the m key on station 13/l 7. SPKR LED steady on. 
    3) Dial gailon the dial pad. (X = Restriction class 
    SPKR LED flashes continuously. 
    1 - 4, as defined in Program 6Xx.) 
    The various LEDs indicate present data. 
    4) Refer to the System Record Sheet. An X on the record sheet means the LED should 
    Using the various keys, turn their associated be on. 
    LEDs on or off, as required. The detailed If the LED is already on, depressing the associated 
    meaning ‘of each key/LED is shown below. key will turn it off and vice versa. LEDs may be 
    NO 
    JE. turned off and on until the desired pattern is set. 
    If any key/LED is not shown, it is not used. 
    this program 
    68) Go to Step 2 in’ar-%-rer program table 
    . . . or . . . 
    6C) Transfer data into working memory per Par- 
    agraph 02.06. SET LED goes off. 
    -61-  
    						
    							TABLE 36 
    PROGRAM 1#00 
    LEAST COST ROUTING HOME AREA CODE ENTRY 
    (LCD EKT REQUIRED-STRATA Vie only)  PROGRAlWMlNG PROCEDURES 
    SECTION 500-0~6-300 
    JANUARY 1988 
    SET LED on. 
    1) Lock in the 
    SET switch on the HKSU. Station 17 LED 19 on. 
    System is in program mode. , 
    Normal functions halt on station 17. 
    LCD: PROGRAM MODE 
    2) Depress the m key on station 17. SPKR LED steady on. 
    LCD: PROGRAM NO.? 
    3) Dial 1311 on the dial pad. SPKR LED flashes continuously. 
    LCD: DATA = (indicates present data) 
    4) Refer to the System Record Sheet. LCD: (displays code entered) 
    Using the dial pad, enter the system’s home 
    area code. 
    NOTE. 
    To clear existing data without entering a 
    new number, depress the 0 key once for 
    each digit. 
    5) Depress the m key to place new data in All station 17 LEDs (except 19) go off. 
    memory. 
    6A) Go to Step 2 in another program table 
    . . . or . . . 
    66) Transfer data into working memory per Par- 
    agraph 02.06. SET LED goes off. 
    Station 17 LED 19 goes off. 
    New data is stored, previous data is erased. 
    -62-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY1988 
    TABLE 37 
    PROGRAM l#OX 
    LEAST COST ROUTING SPECIAL CODES 
    (LCD EKT REQUIRED-STRATA Vie only) 
    1) Lock in the SET switch on the HKSU. SET LED on. 
    Station 17 LED 19 on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    I 1 LCD: PROGRAM MODE 
    I 
    2) Depress the m key on station 17. SPKR LED steady on. 
    LCD: PROGRAM NO.? 
    I 
    3) Dial ilafl on the dial pad. X = 1 - 5 corre- SPKR LED flashes continuously. 
    sponds to five different special codes that LCD: DATA = (indicates present 
    data) 
    may be entered. 
    4) Refer to the System Record Sheet. LCD displays code entered. 
    Using the dial pad, enter -the special code 
    1 5) Depress the m key to place new data in 1 All station 17 LEDs (except 19) go off 
    memory. . 
    6A) Go to Step 2 in another program table 
    . . . or . . 
    6B) Transfer data into working memory per Par- 
    agraph 02.06. SET LED goes off. 
    Station 17 LED 19 goes off. 
    New data is stored, previous data is erased. 
    -63-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 500-036-300 
    JANUARY 1988 
    TABLE 38 
    PROGRAM 1#06 
    LEAST COST ROUTING PARAMETERS 
    (LCD EKT REQUIRED-STRATA Vie only) 
    SET LED on. 
    1) Lock in the 
    SET switch on the HKSU. Station 17 LED 19 on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    LCD: PROGRAM MODE 
    2) Depress the m key on station 17. SPKR LED steady on. 
    LCD: PROGRAM NO.? 
    3) Dial i pa 1 on the dial pad. 
    SPKR LED flashes continuously. 
    LCD: (displays program number) 
    Various LEDs indicate present data. 
    4) Refer to the System Record Sheet. 
    LCD displays code entered. 
    Using keys 00 
    - 02, turn their associated 
    LEDs ON or OFF, as required. 
    5) Depress the m key to place new data in All station 17 LEDs (except 19) go off. 
    memory. 
    6A) Go to Step 2 in another program table 
    . . . or . . . 
    6B) Transfer data into working memory per Par- 
    agraph 02.06. SET LED goes off. 
    Station 17 LED 19 goes off. 
    New data is stored, previous data is erased. 