PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 TABLE 3 SYSTEM DATA PRINTOUT SELECTION CODES PROGRAM NUMBER, .ED o;9 ~ if;, 1 1 I I I 2XY l#XY 2#XY 3XX 3#XX 4XX 4#XX / 5XX 5#XXi 6XX ‘6ttXX’ 7XX I:;;; , / / ( ~ ~ 1 08 XIX xix x x’x/x/x~x/x/xi,xIx’x 07 x1x,x/X x x x/x~x/x/xIx~x!x/x 06 x/x/xix x x x~x/xIx/x/xIxix.x 05 0iOlO ~0 o/o 0 0 i 0 ~010/0~0!0!0 04 ojoio x xlo’x oIx/o,xIo/x~o~o 03 oi0/0/O o!o!oloioio 0i010io;x 02 0 ~o!oio~o!o~o/x/xlx, x I x I x j xix 01 (3 OiX/OlXiXIX!0jojoioIxix X’X 00 0 ’ x /olx;o~x/~!~Io~~i~~~~o~~~x LED on = X LED off = 0 TABLE 3 SYSTEM DATA PRINTOUT SELECTION CODES (continued) I 183XXi86XX189XXI I I 08 X/X~X/X~X 07 I x I x / x 1 x i x 06 XiXiX X/X 05 olo!o 010 04 0 j x i 0 x I x 03 x XIX x/x 02 0 o/ololo 01 olo~o!olx 00 oiolxlxix LED on = X LED off = 0 1 TABLE 4 AUTOMATIC DIALING MEMORY PRINTOUT SELECTION CODES AUTO DIAL LISTS (System & Stations 10 - 25) -25-
PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY1988 DU SYSTEM PROGRAMMING ttU l:SELECT(LEO ON) 21 16 15 8 7 1INT 0 1 000000 00000000 00000000 0 2 000000 00000000 00000000 0 n2 000000 00001000 00000110 0 3 000000 00010000 00000101 0 4 000000 00000000 01110000 0 5 000000 00000000 00000100 0 x5 000000 00000000 00000010 0 6 000000 00000000 00000000 0 !J6 000000 00000000 00000000 0 7 000000 00000000 00000000 0 8 000000 00000000 00000000 0 08 111111 11111111 11111110 0 9 1111:1 11111111 11111110 0 91 111111 11111111 11111110 0 92 000000 00000000 00000000 0 93 000000 00000000 00000000 0 94 000000 00000000 00000000 0 X9 000000 00000000 00000060 BP EN0 OF PRINT ilu FIGURE 4-SAMPLE PRINTOUT OF PROGRAMS 01 - 0#9 -26-
fl:: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ttll SYSTEM PROGRAMMING PD l:SELECT(LEDDN) 00 01 02 03 04 05 06 08 09 10 11 14 18 . 90 / 91 92 93 94 95 96 97 98 21 16 15 8 7 1INT 000000 00000000 00000001 000000 00000000 00000000 000000 00000000 00000000 (CATA = DIAL NLIVXR) 10515 12 10735 9 555s 3621 21 16 000000 000000 1s a 00000000 00000000 l:SELECT(LED ON] 7 1INT 00000000 00000000 000 - 999 000 - 999 . l:SELECT(LED ON] PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 21 16 1s 8 7 1INT 808800 aa 00000000 81 82 83 84 *8 (DATA =DIALNUMBER) END DFPRINT U# FIGURE 5-SAMPLE PRINTOUT OF PROGRAMS 100 - 19X -27-
PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 tfu SYSTEM PROGRAMMING Ptt (DATA = DIAL NUMBER) 2 11 212 2 14 2 21 2 24 472 49s 669 (DFITA = DIAL NUMBER) .317 628 629 (DATA - =DIFlL NUmBERI 2 81 2 a4 UP END OF PRINT UP FIGURE B-SAMPLE PRINTOUT OF PROGRAM 2XY r FIGURE 7-SAMPLE PRINTOUT OF PROGRAM 3XX (4XX - 9xX are identical) -28- utt SYSTEM PROGRAMMING ttP 3 10 3 11 3 12 3 13 3 14 3 15 3 16 3 17 3 18 3 19 3 20 . 3 65 21 16 111111 111111 111111 111111 111111 111111 111111 111111 111111 111111 llJll1 . - I . 111111 ftn END OFPRINT 1s a 11111111 11111111 11111111 11111111 11111111 11111111 11111111 lllllill 11111111 11111111 11111111 . . 11111111 #U l:SELECT[LED ON) 7 1INT 1~111110 11111110 11111110 11111110 11111110 11111110 11111110 11111110 11111110 11111110 11111110 . 11111110 I
1 P3 SYSTEM PROGRAMMING !J1D 4P 10 10 20 co10 09 19 COY 08 18 CO8 07 17 co7 06 16 CO6 as 1s co.5 04 14 co4 03 13 co3 02 12 co2 01 11 co1 . co20 co19 cola co17 CO16 co15 co14 co13 co12 co11 NOTE: Columns f and2 give the code for the feature assigned to each key; coiumns 3 and 4 give the actual features assigned(corresponding to the codes in columns 1 and 2). 40 65 * * * 06 05 04 03 02 01 00 99 96 m2 97 AD1 36 CO6 95 co5 94 co4 93 co3 88 co2 87 co1 8-S INT MWfFL DND RE? RDL FFUJ X8 PRV ICD CFD Sf?VE -29- PROGRAMMING PROCEDURES SECTION 500-036-300 ikUARY 1988 .e .,I OD END OFPRINT DD FIGURE 8-SAMPLE PRINTOUT OF PROGRAM 4#XX
PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 UU REPERTORY DIAL UU u00 *s0 17147305000 l-400 161 19142731750 u00 62 12135551212 u00 X63 17148531212 u00 64 17145551212 u00 165 1714730S000 u00 *66 19142731750 u00 167 12135551212 u00 *68 17148531212 u00 *69 17145551212 u00, 170 17147305000 tt00 171 19142731750 P00 172 12135ss1212 000 *73 17148531212 u00 74 17145551212 u00 *7s 17147305000 000 *76 19142731750 u00 177 12135551212 000 X78 17148531212 u00 *79 17145551212 u00 180 17147305000 000 81 19142731750 000 *a2 12135551212 000 183 17148531212 u00 *Ei4 17145551212 000 *as 17147305000 u00 186 19142731750 u00 87 12135551212 000 *m 17148531212 / u00 89 1714SSS1212 u00 190 17147305000 u00 91 19142731750 000 *92 12135551212 u00 +93 17148531212 000 194 17145551212 u00 19s 17147305000 - 000 196 19142731750 u00 *97 12135551212 u00 90 17148531212 u00 199 17145551212 UU ENDOFPRINT UU FIGURE g--SAMPLE PRINTOUT OF SPEED DIAL-SYSTEM -3o-
TABLE 5 PROGRAM 01 SYSTEM ASSIGNMENTS (BASIC) SET LED on. 1) Lock in the SET switch on the HKSU. 2) Depress the m key on station 13/l 7. Station 13/l 7 LED 19 on. System is in program mode. Normal functions halt on station 13/17. SPKR LED steady on. 3) Dial Ia on the dial pad. SPKR LED flashes continuously. The various LEDs indicate present data. 4) Refer to the System Record Sheet. An X on the record sheet means the LED shou Using the various keys, turn their associated be on. LEDs on or off, as required. The detailed If the LED is already on, depressing the associate meaning of each key/LED is shown below. key will turn it off and vice versa. LEDs may I NOTE. turned off and on until the desired pattern is SC if any key/LED is not shown, it is not used. KEY/LED LED ON LED OFF 17 Transfer Privacy Alternate point answer of transferred CO line -~ ~_--_- --.- - -- 16 Automatic Dialing-Override Toll Restriction Restricted -- ~_--.. . .-~ _-~_-_.~-- -___ 15’ __ CO Line Group(s)-Eight (91-98) CO Line Group(s)-One (9) -~..- ~__. ____ -.___ --- -_-- _ - - 14 Two CO Line Conferencing-inhibit Allowed ___.. _--~~. -_ --- 13 Least Cost Routing No Least Cost Routing -- ~-- 12 DP Make Ratio-33% 40% _--. __ ~- 11 DeTMF Signal Time-l 60 ms 80ms _--. .- - 09 Non-Privacy Privacy 07 Station 13/l 7-l O-key EKT Station 13/l 7-20-key EKT i 06 Incoming Call Abandon-8 seconds 6 seconds - - 05 Pause After Flash-3 seconds 1.5 second ’ 04 Insert Pause After Flash No Pause 03 Pause (m or m key)-3 seconds 1.5 second - 02 Flash-&5 second 2 seconds 00’” Tone First Voice First 5) Depress the m key to place new data in All station 13/l 7 LEDs (except 19) go off. memory. 6A) Go to Step 2 in another program table . . . or . . . 6B) Transfer data into working memory per Par- agraph 02.06. SET LED goes off. Station 13/l 7 LED 19 goes off. New data is stored, previous data is erased. PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 “If the LED 15 is off in this program, see Program 09; if LED 15 is on, see Program 09X. “*Voice First is required if the system is optioned for Off-hook Call Announce. -31-
PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 TABLE 6 PROGRAM O#l DOOR PHONE SELECTION 1) Lock in the SET switch on the HKSU. 4) Refer to the System Record Sheet. the LED should the LED is already on, depressing the associated key will turn it off and vice versa. LEDs may be NOTE. turned off and on until the desired pattern is set. 6B) Transfer data into working memory per Par- agraph 02.06. SET LED goes off. “Station 13 only. -32-
PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 TABLE 7 PROGRAM 02 SYSTEM ASSIGNMENTS (OPTIONS) SET LED on. 1) Lock in the SET switch on the HKSU. Station 13/l 7 LED 19 on. System is in program mode. Normal functions halt on station 13/17. 2) Depress the B key on station 13/l 7. SPKR LED steady on. 3) Dial 8 z on ?he dial pad. SPKR LED flashes continuously. The various LEDs indicate p;escnt data. 4) Refer to the System Record Sheet. An X on the record sheet means the LED should Using the various keys, turn their associated be on. LEDs on or off, as required. The detailed If the LED is already on, depressing the associated meaning of each key/LED is shown below. key will turn it off and vice versa. LEDs may be turned off and on until the desired pattern is set. NOTE. If any key/LED is not shown, it is not used. KEY/LED LED ON LED OFF 13 Station 15/23-Trunk-to-trunk Connection EKT 12 Station 14/22-Trunk-to-trunk Connection EKT --.-__ ~__- 11 Stations 16/l 8 & 17/l g--Amplified Conference Not Amplified -- 10 .- Stations 24 & 25’-Amplified Conference Not Amplified 06 Automatic Callback-Warning Tone No Warning Tone -. 04 LCD Display Dialed Number-l minute 15 seconds 02 Night Ringing over External Page”-Allowed Not Allowed 01 SGM over External Page-Allowed Not Allowed 00 External Page with All Call Page-Included Not Included 5) Depress the m key to place new data in All station 13/l 7 LEDs (except ! 9) go off. memory. 6A) Go to Step 2 in another program table . . . or . . . 6B) Transfer data into working memory per Par- agraph 02.06. SET LED goes off. Station 13/l 7 LED 19 goes off. New data is stored, Drevious data is erased. * STRA TA We orily. **Program 0#8 selects which individual CO(s) will ring. -33-
PROGRAMMING PROCEDURES SECTION 500-036-300 JANUARY 1988 TABLE 8 PROGRAM 0#2 ACCOUNT CODE DIGIT LENGTH SELECTION SET LED on. 1) Lock in the SET switch on the HKSU. Station 13/17 LED 19 on. System is in program mode., Normal functions halt on station 13117. 2) Depress the m key on station 13/l 7. SPKR LED steady on. 3) Dial 3 13 on the dial pad. SPKR LED flashes continuously. The various LEDs indicate oresent data. 4) Refer to the System Record Sheet. Using the various keys, turn their associated If the LED is already on, depressing the associated LEDs on or off, as required. The detailed key will turn it off and vice versa. LEDs may be meaning of each key/LED is shown below. turned off and on until the desired pattern is set. This program also defines the length of the For account code length, as each digit is entered, SMDR account code. Enter a number from 4 the entry is verified by LEDs as shown. to 15 via the dial pad. NOTES. I. Depressing the 1 key displays the data without changing it. 2. To clear existing data without entering a new number, depress the p key two times. KEY/LED LED ON LED OFF 17 Ringing Repeat Standard Ring 15 HDTU Modern Speed-l 200 bps 300 bps 04 - 00 Account Code Digit Length X = LED on All LEDs off = no data . . . or . . . 66) Transfer data into working memory per Par- SET LED agraph 02.06. goes off. c -34-