Home > Toshiba > Communications System > Toshiba Perception Electronic Business Communications System Installation And Maintenance Manual

Toshiba Perception Electronic Business Communications System Installation And Maintenance Manual

Here you can view all the pages of manual Toshiba Perception Electronic Business Communications System Installation And Maintenance Manual. The Toshiba manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 201

NOTES: 
I. XX = List Number. 
00 = System List (90 numbers maximum). 
0 1 I-W 25 = Station Lists (10 numbers each maximum). 
2. Input procedure is: 
Address Code-Space-Access Code-Pause- DN 
For example: 0 I 9 * NPANNXXXX 
3. Stored numbers may be any length between I and ?6 digits; 
” * ” enters a 3second pause and is 
counted as one of the 16 digits. 
4. If the List Number (LNO) was 00 (System List), 2-d&it address codes will be used (10 Q 99). 
5. No further prompt will be given until [DELI is...

Page 202

be coinpleted. if art “Cl , proceecl 
NOTES: 
f. XX = Access Code of the Page Zone or Ail Page. 
2. [CTR L J [XJ = Ignore line entered 
[CTRLJ 
LHJ = Backspace 
[DELJ = Stop printing and return to R.EQ 
[DELJ [DELJ =&OH program 
ERATT 08 
Input data erased because program aborted during NEW data entry. 
ERATT 09 1 Attendant data not assigned to input port (REQ = CHG, OUT).  

Page 203

Procedure - Traffic Measurement 
Authorization Procedure must be completed. If an “OK” response is received, proceed 
as follows: 
ITEM PROMPT 
I USER ENTRY 
OK 
1 DTRF 
- DISK LOADlN6 - 
REQ 
RPT, STT, CHG, OUT 
SYST.DATE MMDDYY 
MMDDYY or [CR] 
SYST.TlME HHMMSS 
HHMMSS or [CR] 
SCH J‘xxxr’ 
30,60, CMD, NONE or [CR] 
STR.DATE MMDDYY 
MMDDYY or [CR] 
STR.TiME HHMM 
HHMM or [CR] 
RPT 
SYST 
Y or N 
ATT0 
Y or N 
ATT1 
Y or N 
TGPOOwTGPl5 Y or N 1 NOTE 
1 
2 
3 
4 
5 
6 
7 
NOTES: 
1. RPT = Report...

Page 204

-3 - 
ITEM 
Authorization Procedure 1 PROMPT 1 USER ENTRY 
OK 
1 TRF 
- DISK LOADING - 
REQ 
RPT 
RPT FROM 
MM DD YY 
HH MM SS 
TO MM DD YY 
HH MM SS 
SYST RCV R DLY 0000 
ATT 0 IN SVC 0000 
WK TIM 0000 
INC TRK 0000 
INC TIM 0000 
0 CALL 0000 
LPS BSY 0000 
TTA 0000 
OVFL 0000 
ATT 1 
(SAME AS ATT 0) 
TRUNKS 
TGP OO* 
INC USE 0000 
INC CALL 0000 
O.G. USE 0000 
O.G. CALL 0000 
ATB 0000 
GROUP 
System 
Attendant #0 ITEM IME 
DTMF RCVR Delay (3 sec.) 
Time in Service TYPE OF ~~ASU~~M~~~ 
Peg Count 
ccs...

Page 205

Procedure - DTM F Receiver 
Authorization Procedure 
as follows: Data Block 
must be completed. If an “OK” response is received, proceed 
ITEM 
Port Number PROMPT 1 USER ENTRY NOTE 
OK ] DRCV 
- DISK LOAQING - 
REQ NEW, OUT 
POR ROOX 1 
REQ 
NOTES: 
I. Enter the RCVR port number (ROO = PCB number, X = Circuit number). 
2. [CTRLI 
[Xl = ignore line entered 
[CTRLJ [HI = Backspace 
[DEL] = Stop printing and return to REQ 
[DEL] [DEL] = Abort program 
Error Codes 
No PCB is equipped in that location....

Page 206

NOTES: 
1. A maximum of 16 Trunk Groups (normally 0 w 15) are possible. If Private Lines are to be equip- 
ped, the code “PVL ” is used in place of 15. 
2. TKT cannot be changed, Data Block must be removed (OUT) and NEW data entered. 
3. XX = Trunk Group to be stepped to if this group is busy. 
4. COS is meaningful only for TiE/CCSA/DlD Trunks. 16 COS groups are provided and are defined 
in the Class of Service Data Block. 
5. List the digit which is to be ignored for the purpose of Toll/Code...

Page 207

rror Codes 
Program Name: Trunk Group Data Block (DTGP) 
Error Code 1 Meaning 
ERTRG 00 1 
ERTRG 01 GRP still has trunk assigned (REQ = OUT). 
ERTRG 02 The entered GRP number is already assigned (REQ= NEW). 
ERTRG 03 One or more trunks are busv (REQ = CHG). 
ERTRG 04 The entered GRP number dkei not exist (iEQ = CHG). 
ERTRG 05 Entered advance step GRP is the same as this GRP number. 
ERTRG 06 
ERTRG 07 
ERTRG 08 #I entered but tenant service not enabled in System Data Block. 
ERTRG 09 #I entered but...

Page 208

Procedure - Trunk Data Block 
Authorization Procedure must be completed. if an “OK” response is received, proceed 
as follows: 
ITEM 
Port Number 
Group/Member Number 
Trunk DN 
Night Number 
Signalling 
Disconnect Supervision? 
Control of Disconnect 
incoming Dialing 
Dialing Outgoing 
Answer Supervision 1 PROMPT 1 
USER ENTRY 
OK 1 DTRK 
- DISK LOAQING - 
REQ 
NEW, CHG, OUT 
POR TNNX 
GMN YYZZ 
TDN BBB 
NIT NNN, NONE (UNA) 
SIG GRD, LOP, EAM, LDR, OAD 
DIS Y or N 
CTL 
OPC, FPR 
DIN 
DIP, TON 
DOT 
PI...

Page 209

Error Codes 
Program Name: Trunk Data Block (DTRK) 
Error Code 1 Meanina 
ERTRK 01 1 PCB is not trunk type. 
ERTRK 02 1 Port is busy (REQ = OUT).  ERTRK 00 1 No PCB is equipped in that location. 
ERTRK 03 1 Port is alreadv assianed fRE0 = NFW) I 
ERTRK 04 1 Trunk Group Data Block does not exist. 
ERTRK 05 / Member number already assigned. 
ERTRK 06 1 Entry conflicts with existing DN or TDN 
ERTRK 07 1 Entered night number does not yet exist. 
1 ERTRK 08 
ERTRK 09 Type of signalling entered conflicts with...

Page 210

Procedure - Print Station Data Block 
Authorization Procedure must be completed. If an “OK” response is received, proceed 
as follows: 
f-?-EM PROMPT 1 USER ENTRY 1 NOTE 
I 
OK 
1 PSDf3 
I 
- DISK LOADING - 
REQ 
I I 1 
- EXECUTE - 
REQ 
I I I 
NOTE I- The folio wing responses are possible: 
PORALL = All SDBs will be output in numerical order of ports (lowest first) 
PORNNX = Port NNX data will be output 
POR VAC = A list of all unassigned ports will be output 
DNALL = All SDBs will be output in...
Start reading Toshiba Perception Electronic Business Communications System Installation And Maintenance Manual

Related Manuals for Toshiba Perception Electronic Business Communications System Installation And Maintenance Manual

All Toshiba manuals