Home > Toshiba > Communications System > Toshiba Perception 1 2 User Manual

Toshiba Perception 1 2 User Manual

Here you can view all the pages of manual Toshiba Perception 1 2 User Manual. The Toshiba manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 331

2. Press the 1 button to access 
alpha characters. 
3. Press the 0 button to move the 
cursor (-) to the desired 
position. 
4. Press the button 
corresponding to the letter 
which you want to enter. 
5. If you want to enter a number, 
press the 1 button to change 
to numeric characters. Press 
the fl button again to return to 
alpha characters. (Refer to the figure on the following page for an explanation of the 
dialpad buttons.) 
(The left edge of the display to program a new message, or two spaces...

Page 332

FAULT FINDING 
SECTlDN200-255-500 
MARCH1991 
FAULT FINDING PROCEDURES  

Page 333

FAULT FINDING 
SECTION 200-255-500 
MARCH 1991 
PARAGRAPH 
1. 
2. 
3. 
4. 
5. 
TABLE SUBJECT 
PAGE 
A 
B 
C FLOWCHARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
1 
ELECTRONIC TELEPHONE CABLE CONTINUITY READINGS 
USING A VOLTMETER 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Page 334

FAULT FINDING 
SECTION 200-255-500 
MARCH 1991 
FIGURE LIST 
FIGURE TITLE 
PAGE 
1 
2 
3 FLOWCHART SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~. 
PERCEPTION, POWER SUPPLY VOLTAGE CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5: 
PERCEPTION, POWER SUPPLY VOLTAGE CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 
.~.. . 
,. 
-ii-  

Page 335

FAULT FINDING 
SECTION 200-255-500 
MARCH 1991 
1. GENERAL 
1.01 
This section describes the maintenance 
procedures that are used for the diagnosis of faults 
in the PERCEPTlONe and PERCEPTIONex Dig- 
ital Hybrid/ PBX systems. To eliminate system 
faults, faults must first be classified and then cleared 
by replacing the defective apparatus. Operational 
tests can then be performed to verify correct appa- 
ratus operation. To perform operational tests, fol- 
low the fault-clearing flowcharts and the...

Page 336

FAULTFINDING 
SECTIONZOO-255-500 
MARCH1991 
Start and end of a flow- 
chart sequence 
Important notes affecting 
the fault clearing procedure 
.-----i 
Question to be answered 
YES or NO. 
0 
Progression TO or FROM 
another flowchart. Page 
numbers indicate the loca- 
tion of the flowchart within 
this manual. Lettersdenote 
0, 
the exact entrance or exit 
point in the flowchart. 
Statement of a required 
action 
-.A..-- A -. -...a..m-- -.-mm--. I 
the affected PCB should be replaced. Alarm and 
fault...

Page 337

TABLEB-ELECTRONICTELEPHONE 
CABLECONTINUITYREADINGS 
(Using a voltmeter) 
*Nominal voltage- within the power supply 
limits of 23.2 w 28.2 VDC, while under AC 
power. 
3) An improper reading indicates an open, crossed, 
or shorted wire. 
4) Forthe MDF-to-electronic/digital telephone/DSS 
console cable, a more precise check can be 
made by using an ohmmeter (See 5.03). 
5.03 Check electronic/digital telephone and DSS 
console cable continuity by using an ohmmeter, as 
follows: 
1) 
2) 
3) 
4) 
Disconnect...

Page 338

FAULTFINDING 
SECTlON200-255-500 
MARCH1991 
CHART NO. 1 
FAULT CLASSIFICATION 
xi ---------------------- pijfjy 
J 
To 
/ 
‘i 
START 
I NO 
Switch the main circuit 
breaker (power) 
to ON. 
- Wait approx. 30 
seconds for the 
system to load. 
YES 
__-___ 
---_ 
YES I- 
NOTE: See Section 
200-255-200, 
Installation, 
Chapter 4 
Paragraphs 7.01& 7.02 
(System Power Up). 
-4-  

Page 339

FAULT FINDING 
SECRDN 200-255-500 
MARCH 1991 
CHART NO. 1 
FAULT CLASSIFICATION (continued) 
date on attendant 
console or with 
the DTRF Program 
NOTE: It station’s 
voice comm. (including 
all related features) - 
is free of faults, the 
answer is YES. system functional 
-5-  

Page 340

FAULT FINDING 
SECTION 200-255-500 
MARCH 1991 
CHART NO. 1 
FAULT CLASSIFICATION (continued) 
From 
FC3 
Page 5 
2 Press the INIT 
key on the NPRU 
momentarily. 
‘Wait a few 
seconds for 
initialize to 
complete. 
Press the LOAD 
key on the NPRU 
momentarily. 
* Wait approx. 30 
seconds for re-load 
to complete. 
I I 
I 
A To- 
 
1 YES 
NOTE: See Section 
200-255-200, 
/nsra//ation, --- 
Chapter 4, 
Paraaraphs 7.01 and 7.02 
’ FC4 
Paoe 7 
-6-  
Start reading Toshiba Perception 1 2 User Manual

Related Manuals for Toshiba Perception 1 2 User Manual

All Toshiba manuals