TiE Businesscom Plus Hardware Manual
Here you can view all the pages of manual TiE Businesscom Plus Hardware Manual. The TiE manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 111
INSTALLING OPTIONAL EQUIPMENT Installing the Modular Adaptor The Modular Adaptor (P/N 62598) simplifies the installation of stations in a BUSINESSCOM PLUS only.Two connectors are recommended for each system. This section provides information on installing a Modular Adaptor. Refer to Figure 2-34 Modular Adaptor Installation: 1. The on the back of the adaptor is connected to either or B2 on the side of the KSU. The screws on the adaptor are screwed into predrilled holes in the KSU. 2. Mount the...
Page 112
INSTALLING OPTIONAL EQUIPMENT Mounting Bracket (offset) Modular Adaptor FIGURE 2-34 MODULAR ADAPTOR INSTALLATION 2-60
Page 113
INSTALLING OPTIONAL EQUIPMENT Installing and DISA Ports This section provides information on installing the PCB in a BUSINESSCOM PLUS or the B-STU-D PCB in a BUSINESSCOM PLUS Both are used for Off-Premises Extensions and DISA ports. External Ring GeneratorUse of the or B-STU-D for requires an External Ring Generator power source in order to provide non-interrupted ring generator output in the range of 90 VAC at a nominal frequency of 20 Hz. External Talk BatteryThe or B-STU-D for On-Premise...
Page 114
INSTALLING OPTIONAL EQUIPMENT. Installing the PCB, BUSINESSCOM The PCB is inserted in place of the PCB. Refer to Figure 2-7 BUSINESSCOM KSU (P/N 15000 or P/N 15001 and Figure 2-35 Installation of PCB: 1. 2. 3. 4. 5. Strapping on the PCB: o Strap and S-2 l-2 for Internal Talk Battery or 2-3 for External Talk Battery. o Strap S3 and S5 l-2 for Port 20 to be used as an OPX port or 2-3 for a DISA port. o Strap S4 and S6 1-2 for Port 21 to be used as an OPX port or 2-3 for a DISA port. Strapping on...
Page 115
INSTALLING OPTIONAL EQUIPMENT TIE Ring Generator Connections Station-to-MDF Connection To connect each single line station to the Main Distribution Frame at the HSU (see Figure 2-36 and Table 2-4, BUSINESSCOM PLUS B2 Block Connections): 1. Connect the pair of wires from the station to the D clips of the AT/AR pair on the B Block corres- ponding to the station number being installed. 2. Install bridging clips. Each PCB must be connected to a ring generator source. Connect the TIE Ring Generator (P/N...
Page 116
INSTALLING OPTIONAL EQUIPMENT Block Key telephone Station 18 WHT-RRN JKey telephone Station 19 phone BLK-BRN Ext Bells Line Ext Bells Line YEL-BRN External Alarm Input External Alarm Input FIGURE 2-36 OFF-PREMISES EXTENSION CONNECTIONS, BUSINESSCOM PLUS 2-64
Page 117
INSTALLING OPTIONAL EQUIPMENT TABLE 2-4 BUSINESSCOM PLUS B2 BLOCK CONNECTIONS 25 Pair CableIConnecting Block -- 261 2 3GRN-WHT 29 4 BRN-WHT 30 5 SLTWHT31RED-BLU 6 BLU-RED 32 7 33 a 34 9 35 10 36 1137 12 -- 13 39 14 4015 41 16 4217 43la 4419 45 20 46 21 47 22 4823 49 24 50 25Color Code ORN-WHT RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT BLK-BLU ORN-BLK GRN-BLK BRN-BLK YEL-BLU BLU-YEL YEL-ORN ORN-YEL YEL-GRN GRN-YEL YEL-BRN BRN-YEL VIO-BLU 1TSAR 4 5 OAT OAROBT a 9 12 1314 1516 17OPX Gen...
Page 118
INSTALLING OPTIONAL EQUIPMENT Installing the B-STU-D PCB This section provides information for installing the B-STU-D PCB in a BUSINESSCOM PLUS used for or DISA. SpecificationsElectrical: Dial Pulse Rate: 10 or 20 Pulses Per Second Make/Break Ratio: % Cable Requirements: On-Premises Single Line Telephone, Internal Battery: Loop Limit (max.) 300 ohms: 22 AWG, 8,000 ft. (2.4 km) 24 AWG, 5,000 ft. (1.5 km) Off-Premises Station thru Equipment, Ext. Battery: 24-Volt Battery, Interface 48-Volt...
Page 119
INSTALLING OPTIONAL EQUIPMENT B-STU-D PCB B-STU-D PCB 4 Off-Premises FIGURE 2-37 B-STU-D PRINTED CIRCUIT BOARD Off-Premises Extension Single Line Telephone Connect to ETHEarth Ground Bridging Clips FIGURE 2-38 OFF-PREMISES CONNECTIONS, BUSINESSCOM PLUS 2-67
Page 120
INSTALLING OPTIONAL EQUIPMENT Ring Generator Connection ,Each B-STU-D PCB must be connected to the ring generator source.Connect to the MDF as follows (see Figure 2-38, Table 2-5, and Table 2-6): 1. Connect the output terminals from the Ring Generator to the D clips of the first circuit pair on the B Block. 2. Install bridging clips. For TIE Ring Generator only: 1. Connect the input terminal designated + from the RG to the second circuit clip. 2. Connect the input terminal designated G from the RG to...