SYSTEM TROUBLESHOOTING Basic System Operation Visible symptoms with power on: 1. Examine and record any improper indications on all telephones, including key depression as well as lamp and LED displays. 2. Locate the Port 10 Display telephone, and check to see if the hyphen in the Clock display is flashing sec. on, off). If the hyphen is not flashing or there is no display, the phone is not operating or the system MPU/CPU card clock is not running. 3. Check Clock LED on MPU/CPU card. Normal condition...
Page 142
SYSTEM TROUBLESHOOTING Problem Related to One Card or One Group of Telephones/Lines Remove and firmly reinsert the PCB experiencing the condition. 2. Temporarily swap this PCB with another similar PCB in a different KSU location. 3. Remove all of a similar type from the KSU (i.e.,all station or all CO Line and replace them one at a time. Check system operation after inserting each PCB. A problem on one circuit card can affect the operation of another PCB in the system. 4. Temporarily swap the...
Page 143
SYSTEM TROUBLESHOOTING Problems Related to Lines 1. Disconnect system from CO Line input, and meter CO Line protection fuses to verify continuity. 2. Verify that necessary CO Line Expansion and Matrix expansion cards are installed in the correct positions. 3. Measure Loop Current of all lines, as well as Ringing Voltage,On-Hook and Off-Hook Voltages. 4. Verify that each telephone number is associated with the line connection that is indicated. 5. Verify that the connections between the registered jacks...
Page 144
III-3 POWER SUPPLY FUSES Be sure to replace a blown fuse only with one of the same type and power requirement. TABLE 3-3 POWER SUPPLY FUSES FOR BUSINESSCOM PLUS SYSTEMS Fuse Function Indication of Failure NITSUKO POWER SUPPLY FOR THE BUSINESSCOM PLUS P/N 62505 or P/N 15420) Power Supply Protection Red LED off NITSUKO POWER SUPPLY FOR THE BUSINESSCOM PLUS P/N Power Supply Protection Green Neon Lamp off All Power Supply off Transformer Thermal Fuse All Power Supply off...
Page 145
III-3POWER SUPPLY FUSES TABLE 3-3 POWER SUPPLY FUSES FOR THE BUSINESSCOM PLUS SYSTEM Fuse FunctionIndication of Failure NITSUKO POWER SUPPLY FOR THE BUSINESSCOM PLUS 64 P/N Power Supply Protection Transformer Thermal Fuse Protection (located in Control Circuit) Battery Protection 5-Volt Supply Protection Supply Protection 28-Volt Supply Protection for Audio 28-Volt Supply Protection for Telephones 28-Volt Supply Protection for Telephones 28-Volt Supply Protection for Telephones...
Page 146
III-3POWER SUPPLY FUSES TABLE 3-3 POWER SUPPLY FUSES FOR BUSINESSCOM PLUS SYSTEMS F u s e Function Indication of Failure HARMER SIMMON POWER SUPPLY FOR THE BUSINESSCOM PLUS 64 P/N 15323H or HS118, P/N 15320H) Applied AC switch on Green AC NORMAL LED on 250 VAC and all voltage off output functional red LED off output functional red LED off 28V output functional28V red LED off Battery Backup Box supplies power for system operationBATT OP red LED off out under normal AC power HARMER SIMMONS BATTERY...
Page 149
BUSINESSCOM PLUS’” Software Manual Software Release 3 (Enhanced Software Package) System Practice 01652 Issue l-lAugust 21, 1987
Page 150
This manual has been developed by TIE/communications, Inc. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions for improving this manual would be appreciated. Forward your remarks to: TIE/communications, Inc. 8 Progress Drive Shelton, 06484 Attention: Manager, Technical Publications