TABLE 2-5 B-STU-D STATION BLOCK CONNECTIONS
25 PAIR CABLECONNECTING BLOCKS CIRCUIT
Color
Pin Code
26 WHT-BLU
1BLU-WHT272ORN-WHT
28WHT-GRN3GRN-WHT294BRN-WHT
30531RED-BLU
6
32 RED-ORN
7 ORN-RED
33 RED-GRN
8 GRN-RED
34 RED-BRN
9 BRN-RED
35 RED-SLT 10 SLT-RED
36 ELK-BLU
11BLU-BLK3712 ORN-BLK
38
13 GRN-BLK
39 BLK-BRN
14 BRN-BLK
40
15 SLT-BLK41YEL-BLU
16 BLU-YEL
42 YEL-ORN
17 ORN-YEL
43 YEL-GRN
18 GRN-YEL
44 YEL-BRN
19 BRN-YEL
45 YEL-SLT
20
46 VIO-BLU2147 VIO-ORN
22
48 VIO-GRN
23...

Page 122

INSTALLING OPTIONAL EQUIPMENT
TABLE 2-6  BLOCK STATION LOCATIONS
POSITION
STU4
STU7
STU12
STU13
STU14
BLOCK
B3
B6
FOR
STATIONS
1013
14
17
18
21
2225
26
29
30
33
34
37
41
4245
46
49
50
53
54 57
58
61
6265
66
69
70
73
01651-L-l
T1651lM.G3
2-70 

Page 123

INSTALLING OPTIONAL EQUIPMENT
Installing the
B-TBU-C PCB The B-TBU-C PCB PCB provides Headset operation to
the telephone in which it is installed. The customer
must supply the modularly-connected carbon headset.
This section provides information on installing the
B-TBU-C PCB in any Series 2 telephone in the system
(see Figure 2-39Installation of B-TBU-C PCB).
To
1.
2.
prepare the telephone for headset operation:
Remove the two screws on the base of the phone.
Separate the top of the telephone from the...

Page 124

INSTALLING OPTIONAL EQUIPMENT
FIGURE 2-39INSTALLATION OF B-TBU-C PCB
2-72 

Page 125

INSTALLING OPTIONAL EQUIPMENT
Installing the SMDR PCB
For use of the Station Message Detail Recording
feature,either PCB must be installed in the
system:
SystemP/N
BUSINESSCOM PLUS 
B-SMDR-SA15075
BUSINESSCOM PLUS B-SMDR-LA15345
Each SMDR PCB has three option switches that must be
set (see Figures 2-40 and 
Option
Switch SW1Option Switch SW1 contains eight toggles that select
SMDR options.Select options from the chart below,
and set each toggle to the proper position:
Switch 
Switch Option
Dial Digits
*...

Page 126

INSTALLING OPTIONAL EQUIPMENT
----------------------------------------------------------------------
NOTE: Switches Shown Turned Clockwise.
FIGURE 2-40 B-SMDR-SA PCB (P/N 150751,
BUSINESSCOM PLUS 
FIGURE 2-41 B-SMDR-LA PCB (P/N 153451,
BUSINESSCOM PLUS 
2-74 

Page 127

INSTALLING OPTIONAL EQUIPMENT
Installing the SMDR PCB 
Baud Rate
 Switch SW3Slide Switch SW3 sets the Baud Rate for transmitting
SMDR data to the printer.Set the switch to the proper
Baud Rate position: a Baud Rate of 2400 or less is
preferable.
B-SMDR-SA
 Refer to Figure 2-42B-SMDR-SA PCB Assembly and 
Figure 2-41 B-SMDR-SA Installation.
To prepare the KSU for installation:
1. Remove the KSU cover.
2. Remove the rectangular piece of black metal located
below the ground lug  on the left side of the
KSU....

Page 128

INSTALLING OPTIONAL EQUIPMENT
FIGURE 2-42 B-SMDR-SA PCB ASSEMBLY 

Page 129

INSTALLING OPTIONAL EQUIPMENT
FIGURE 2-43 B-SMDR-SA INSTALLATION 

Page 130

INSTALLING OPTIONAL EQUIPMENT
B-SMDR-LA
Installation To install the B-SMDR-LA (P/N 15345) in the KSU
 of the BUSINESSCOM PLUS  (see Figure 2-44
B-SMDR-LA Installation, BUSINESSCOM PLUS 
1. Remove KSU cover.
2. With components facing left, insert the B-SMDR-LA
PCB into the MISC slot.
3. With components facing left,insert the B-MPU-B/C
PCB into the MPU slot.
4. Mount the SMDR Jack and Cable Assembly on the
backboard.
5. With the red wire on top, insert the ribbon cable
on the Assembly into the 
 connector...
Start reading TiE Businesscom Plus Hardware Manual

Related Manuals for TiE Businesscom Plus Hardware Manual

All TiE manuals