Chapter3Exchanging and updating data using a HotSync® operation121 Advanced HotSync® operations 4Click Change. The Change HotSync Action dialog box appears. 5Click the direction in which you want to write data, or click Do nothing. 6Click OK. 7Repeat steps 2 through 6 to change conduit settings for other applications (or users). 8Click Done. Notes • Any change in the HotSync setting from the default affects only the next HotSync operation. Thereafter, the HotSync Actions revert to their default settings. To use a new setting on an ongoing basis, check the Set as default box. • To restore the default settings, click Default in the Custom dialog box.
Chapter3Exchanging and updating data using a HotSync® operation122 Advanced HotSync® operations Conducting an IR HotSync operation You can use the IR (infrared) port of your CLIE handheld to perform an IR HotSync operation with a computer equipped with an IrDA (Infrared Data Association) IR port. An IR HotSync operation allows you to perform a HotSync operation without using the cradle. Before you start performing an IR HotSync operation Check the following: • Your computer is equipped with an infrared port supporting the IrDA standards. • The infrared port of your computer is enabled for Windows use. To enable the IR port with Windows, see the manual of the computer you are using or the Windows online help. • Which port number is allocated to the infrared port. Check the infrared port number in the Infrared Monitor in the Control Panel. For information on the Infrared Monitor, see the manual of the computer you are using or the Windows online help. Preparing your computer To perform an IR HotSync operation, you have to allocate a virtual port to an IR HotSync operation. 1Click the HotSync icon in the Windows task tray (bottom- right corner of the taskbar) and then select Local Serial from the shortcut menu. 2Click the HotSync icon in the Windows task tray again and then select Setup from the shortcut menu. The setup dialog box is displayed. Continued on next page
Chapter3Exchanging and updating data using a HotSync® operation123 Advanced HotSync® operations 3Click the Local tab to change the setting for an IR HotSync operation as needed. •Serial Port: Specifies a virtual port for an infrared port. If you are not sure of the connection port, see the Infrared Monitor in the Windows Control Panel. •Speed: Determines the speed at which data is transferred. Try the “As Fast As Possible” rate first, and then adjust downward if you experience problems. 4Tap OK. Your computer is ready to perform an IR HotSync operation. Note When performing a local HotSync operation with the cradle after you make the HotSync Setup settings for an IR HotSync operation, you should restore the local HotSync settings. For details, see “To restore the local HotSync settings” on page 124. Performing an IR HotSync operation After you prepare your computer and your CLIE handheld, and then select your Conduit Setup options, you are ready to perform an IR HotSync operation. 1Rotate the Jog Dial™ navigator to select HotSync and then press the Jog Dial navigator. Or tap the HotSync icon on the Application Launcher screen. The HotSync dialog box appears. 2Tap Local. 3Tap the arrow V beneath the icon and then select IR to a PC/Handheld from the drop-down list. 4Point the IR port of your CLIE handheld directly at the IR port of the receiving computer. Continued on next page
Chapter3Exchanging and updating data using a HotSync® operation124 Advanced HotSync® operations Tip For best results, your computer and your CLIE handheld should be 4 to 8 inches (approximately 10 to 20 centimeters) apart, and the path between your CLIE handheld and the computer must be clear of obstacles. 5Tap the icon. The HotSync operation starts. Wait for the message showing that the HotSync operation is complete. To restore the local HotSync settings 1Connect the cradle to your computer. 2Click the HotSync icon in the Windows task tray and clear the check mark of Local Serial from the shortcut menu. 3Click the HotSync icon in the Windows task tray again and then select Setup from the shortcut menu. The setup dialog box is displayed. 4Click the Local tab to display the setting for a local HotSync operation as needed. 5Click OK. Your computer is now ready to perform a local HotSync operation.
Chapter3Exchanging and updating data using a HotSync® operation125 Advanced HotSync® operations Conducting a HotSync operation via modem You can use a modem to synchronize your CLIE handheld when you are away from your computer. A HotSync operation via modem allows you to back up your CLIE data to your computer away from your computer. Notes • The first HotSync operation must be local, using the cradle. After that, you can perform a modem HotSync operation. • It may take many minutes to complete a HotSync operation via modem. To minimize the time required to synchronize data with a modem, we suggest you define the files and/or applications you synchronize during a modem HotSync operation in advance. For details, see “To select the conduits for a modem HotSync operation” on page 129. Before you start performing a HotSync operation via modem Check the following: • A modem or terminal adapter is connected to your computer. • The CLIE Modem PEGA-MD700 (not supplied) must be connected to your CLIE handheld. • The Palm Desktop for CLIE software must be properly configured for use with the modem. A HotSync operation with the PC at home Your CLIE handheld away from your PC
Chapter3Exchanging and updating data using a HotSync® operation126 Advanced HotSync® operations Preparing your computer There are a few steps you must perform to prepare your computer for a modem HotSync operation. Be sure to perform these steps before you leave your office or home so that your computer is ready to receive a call from your CLIE handheld. 1Check the following to prepare your computer for a modem HotSync operation: • The computer modem must be connected to your computer and both the modem and computer are turned on. • No communication applications, such as fax or telephony software, are running on the COM port. • The computer is disconnected from all online services. This helps to avoid conflicts with the COM port. 2Click the HotSync icon in the Windows task tray (bottom- right corner of the taskbar) and then select Modem from the shortcut menu. 3Click the HotSync icon in the Windows task tray again and then select Setup from the shortcut menu. The Setup dialog box is displayed. 4Click the Modem tab. Continued on next page
Chapter3Exchanging and updating data using a HotSync® operation127 Advanced HotSync® operations 5Adjust the following options as needed. •Serial Port: Identifies the port for the modem. If you are unsure of the port assignment, look at the Modem Properties in the Windows Control Panel. •Speed: Determines the speed at which data is transferred. Try the “As Fast As Possible” rate first, and then adjust downward if you experience problems. This setting allows the Palm Desktop for CLIE software and your CLIE handheld to find and use the fastest speed. •Modem: Identifies the modem type or manufacturer. Refer to your modem manual or face plate for its type or settings. If you’re not sure of your modem type or your modem doesn’t match any that appear in the list, select Hayes Basic. •Setup String: Identifies the setup string for your particular modem. Not all modems require a setup string. Refer to your modem manual and enter a setup string if recommended by the manufacturer. 6Click OK. Preparing your CLIE handheld Follow the procedures below to prepare your CLIE handheld for a modem HotSync operation. 1Rotate the Jog Dial navigator to select HotSync and then press the Jog Dial navigator. Or tap the HotSync icon on the Application Launcher screen. The HotSync dialog box appears. 2Tap Modem. Continued on next page
Chapter3Exchanging and updating data using a HotSync® operation128 Advanced HotSync® operations 3Tap the arrow V beneath the icon and then select the modem type from the drop-down list. Select Sony CLIE Modem. 4Tap the Enter Phone # field. The Phone Setup dialog box is displayed. 5When using Sony CLIE Modem PEGA-MD700, skip to step 6. When using another modem or adapter, change the settings as follows: 1Enter the telephone number used to access the modem connected to your computer. If needed, enter a dial prefix (such as “9”) to access an outside line, and then tap the Dial prefix check box. You can enter a comma in the field to introduce a “pause” in the dialing sequence. Each comma equals a two second pause. 2If the phone line you’re using for your CLIE handheld has Call Waiting, select the “Disable call waiting” check box to avoid an interruption during the modem HotSync operation. Continued on next page
Chapter3Exchanging and updating data using a HotSync® operation129 Advanced HotSync® operations 3If you want to use a calling card to place the call, select the “Use calling card” check box and enter the calling card number. Note If you plan to connect to your company’s dial-in server (network modem) instead of connecting to a computer modem, see “Conducting a HotSync operation via a network” on page 131. 6Tap OK. The HotSync screen is displayed again. To select the conduits for a modem HotSync operation The Conduit Setup dialog box on your CLIE handheld enables you to define which files and/or applications synchronize during a modem HotSync operation. You can use these settings to minimize the time required to synchronize your data when using a modem. To change the Conduit Setup for a modem HotSync operation: 1Rotate the Jog Dial navigator to select HotSync and then press the Jog Dial navigator. Or tap the HotSync icon on the Application Launcher screen. The HotSync screen appears. 2Tap the Menu icon. 3Tap Options, and then tap Conduit Setup. The Conduit Setup screen is displayed.
Chapter3Exchanging and updating data using a HotSync® operation130 Advanced HotSync® operations 4 Tap the check boxes to clear the selection of the files and applications that you do not want to synchronize during a modem HotSync operation. The default setting is to synchronize all files. Note Applications that do not have a database (such as games) do not synchronize, even if you select the item in the Conduit Setup dialog box. 5Tap OK. Performing a HotSync operation via modem After you prepare your computer and your CLIE handheld, and then select your Conduit Setup options, you are ready to perform a modem HotSync operation. 1Rotate the Jog Dial navigator to select HotSync and then press the Jog Dial navigator, or tap the HotSync icon on the Application Launcher screen. The HotSync screen appears. 2Tap the icon. A HotSync operation starts. Wait for the message showing that the HotSync operation is complete.