Home > Siemens > Communications System > Siemens Saturn Iie Epabx Installation Test Procedures Manual

Siemens Saturn Iie Epabx Installation Test Procedures Manual

Here you can view all the pages of manual Siemens Saturn Iie Epabx Installation Test Procedures Manual. The Siemens manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 1

Siemens Practices
Installation Series:
A30808-X5130-8120-1-89281
Issue 1, May 1986
’1
!Issued by Office Systems Group
5500 Broken Sound Boulevard 
N.W., Boca Raton, Florida 33431--___________-Siemcns Information Systems, Inc.(305) 994-8100 l Telex: 515052
----- - ..- -----
Printed in U.S.A. 

Page 2

SATURN IIE EPABXA30808X5130-8120-1-8328Installation Test ProceduresIssue 1, May 1906SECTIONPAGE
l.CO INTRDCUCTlON............;..............1-lPurpose..................................l-l
scope....................................
1-lSiemens SATURN IIE Practices.................l-l
Siemens Customer Support Services............l-l
2.00 
PREP/%KGXIY ACTIVITY...................2-1Cener21..................................2-1Test Equipment Required....................2-lHandling Precautions for PC& with
MOS...

Page 3

SATURN IIE EPABX
installation Test ProceduresA30808-X5130-0120-l-0928Issue 1, May 1986.
1.01Purpose. The equipment comprising the SATURN IiE(SATURN Ii-Expanded) System is compleYely tested at the fac-
tory prior to shipment. The inspections and tests covered in
this practice verify that the EPABX equipment has been
properly installed; ensure that no damage 
wasIncurred dur-
ing transit; and confirm that the sysiem is completely opera-
tional. Table 1.00 defines the mnemonics usedthroughout...

Page 4

SATURN IIE EPABX
Installation Test Procedures
.Table 1.00 Mnemonics Used in This Practice (Continued)
[\fiNEMDNIC *DEFINITION
RAUPRemote Access Unit/Ports
RGENRing Generator
S-416Subscriber Line Module Analog - 16 lines
SLMASubscriber Line Module Analog
SLMA-SSubscriber Line Module Analog 
- Station
SLMDSubscriber Line Module Digital
SMXTGSignal Multiplexer/Tone GeneratorSPCStored-Program-ControlledSPGSingle Point Ground
TMBA-2Two-Wire E&M Trunk
TMBA-4Four-Wire E&M Trunk
TMBMCentral Office Trunk...

Page 5

SATURN IIE EPABXA30808-X5130-B120-l-8928Installation Test ProceduresIssue 1, May 1986
2.01General. This section describes the test equipment re-
quired to perform the installation test procedures, handling
precautions for Printed Circuit Boards 
(PCBs) with Metal Ox-
ide Semiconductor (MOS) integrated circuits, guidelines for
removal and replacement of 
PCBs and powei supplies, and
initial visual inspection procedures.
2.02Test Equipment Required. The following test equip-
ment is required to perform the...

Page 6

-
Table 2.00 PC3 and Power Supply Remcval Guidelines
I’AODIJLE ORSERVEC”SPECIAL
UNITSTATEINSTRUCTKWIS
CIOPNA
CONF. NA
DTMF00s
FDDO, 
FDDlNALTUCfNA
LTUPSlNA
MCA
MEM3
kzMEM4NAMSMl
NA
MSM Baitery lNAPIMD00sPSCNAPSUNA
RAUP
NA
SLAl600sSLMA-000s
SLMA-S
003SLMD00s
SMXTGESTMBA-2
TMBA-4
00s
TMBM
00s
TMIE00s-48PS.lNA-48PStfNA
* Optional depending upon customer/system requirements.
NA = Not Applicable; 00s = Out-of-ServiceNotes 1 and 2
Notes 1 and 2
Note 3
None
Note 4
Note 5
Notes 1 and 2
Notes 1 and 2
Notes 
1 and...

Page 7

I.-
A30808-X5130-B120-l-8928Issue 1, May 1986 SATURN IIE EPABX
Installation Test Procedures
Table 2.01 Visual Inspection
STEPVISUAL INSPECTIONREFERENCE
1Check that the cabinet ac power cord is not connected to an
electrical outlet.
2Check that the -48Vdc power supply is strapped forSATURN IIE EPABX Installation11OVac or 22OVac.Procedures Practice (Section 4.00)
3Check that all circuit breakers on the Power System UnitSATURN IIE EPABX Installation
(PSU) are in the OFF position and fuses...

Page 8

w3w13-I  
ISATURN 
IIE EPABX,xtallation Test ProceduresA30808-X5130-B120-l-5928Issue 1, May 1986
Figure 
2.00Signal Cable Distribution for the SATURN IIE System (Basic Cabinet) 

Page 9

SATURN IIE EPABX
Installation Test ProceduresA30808-X5130-B120-l-8928issue 1, May 1986
W23EXPANSION CABINET
\
I--- ---
: ]1FDD 
:, 
i;wi!
i-L--i-- - _-__--
LiTJ-. - -
-r----- *
W22BASIC CA&NET
A5040-2.313186Figure 2.01Signal Cable Distribution for the SATURN IIE System (Expansion Cabinet)
2-5 

Page 10

SATURN IIE EPABXtnstallation Test ProceduresA30808-X5130-8120-1-8928Issue 1, May 1986
LTUSOLINE TRUNK UNIT SHELFJ42
J43
r JPL
JlBASS
BASIC SHELFEl a----
J46J47
E2
05039.1..wmGFigure 2.02Power/Ground Distribution for the SATURN IIE System (Basic Cabinet)
2-6 
Start reading Siemens Saturn Iie Epabx Installation Test Procedures Manual

Related Manuals for Siemens Saturn Iie Epabx Installation Test Procedures Manual

All Siemens manuals