Runco XP-50DHD Plasma Display User Manual
Here you can view all the pages of manual Runco XP-50DHD Plasma Display User Manual. The Runco manuals for Display are available online for free. You can easily download all the documents as PDF.
Page 71
Operation PlasmaWall XP Series Installation/Operation Manual 55 PREL IMINARY Color Space: Select Color Space from the Service menu to choose the color space of the source signal for HDMI, RGB, and component connections. The default setting, Auto, functions as follows: HDMI: If the Auxiliary Video Information (AVI) infoframe contains color space and/or range data, the PlasmaWall uses that information. Otherwise, for RGB sources, the PlasmaWall uses the RGB-Video color space. For component SDTV and...
Page 72
Operation 56 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY CUE (Chroma Upsampling Error) Correction: Some DVD players use MPEG decoders that do not correctly “upsample” the 4:2:0 format chroma information on the DVD to the 4:2:2 or 4:4:4 format required by the video encoder of the display device. This so-called “chroma bug” sometimes causes streaky or spiky horizontal lines running through the chroma channel. It is most noticeable in static, interlaced scenes and on diagonal edges...
Page 73
Operation PlasmaWall XP Series Installation/Operation Manual 57 PREL IMINARY System Reset: To reset ALL controller settings (including image settings) back to their factory defaults, choose System Reset from the Service menu. A confirmation message appears. Select Yes to continue with the reset or select No to cancel. This action is not undoable. Proceed with caution! Before you perform a System Reset, save your “Custom” Memory Presets ( page 47) and ISF Day/Night Memory Presets (page 51)....
Page 75
PlasmaWall XP Series Installation/Operation Manual 59 PREL IMINARY 5.1 Cleaning Regular cleaning will extend the life and performance of the PlasmaWall. Before cleaning, be sure to unplug the power cord from the power outlet. Cleaning the Display Panel Body and Remote Control Do not under any circumstances use solvents such as benzene or thinner to clean the PlasmaWall. Doing so may cause deterioration or peeling of paint from the display or remote control unit. Wipe the display and remote control...
Page 76
Maintenance and Troubleshooting 60 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY 5.2 Troubleshooting Tips Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the PlasmaWall. If the suggested solutions fail to resolve the problem or if you encounter an issue not described here, please contact your Runco dealer or Runco Technical Support. Table 5-1. Troubleshooting Chart SymptomPossible Cause(s)Solution The display does not turn on after...
Page 77
Maintenance and Troubleshooting PlasmaWall XP Series Installation/Operation Manual 61 PREL IMINARY RGB-HD images appear “noisy.” Clock and Phase settings need adjustment. Adjust Clock and Phase settings (refer to Input Color on page 51). Computer images do not dis- play correctly. The resolution and frequency of the video card in the computer are not compatible with the PlasmaWall. Select a compatible resolution and vertical frequency (refer to Supported Timings on page 76). The...
Page 78
Maintenance and Troubleshooting 62 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY Notes:
Page 79
PlasmaWall XP Series Installation/Operation Manual 63 PREL IMINARY In addition to using the DHD Controller front-panel keypad or remote control unit, there are two methods of controlling the PlasmaWall and DHD Controller externally: Using a serial (RS-232) link to send ASCII commands and receive responses to those commands. Using discrete infrared (IR) codes to program a third-party remote control unit. The following sections describe both of these methods. 6.1 Serial Communications The DHD...
Page 80
External Control 64 PlasmaWall XP Series Installation/Operation Manual PRELI MINARY Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the DHD...