Page 51
Operation PlasmaWall XP Series Installation/Operation Manual 35 PREL IMINARY 4.3 Using the On-Screen Menus To display the Main Menu, press the MENU button on the remote control (Figure 2-5) or DHD Controller front panel (Figure 2-3). To select a menu item, use the and buttons on the remote control or DHD Controller front panel to highlight it. Then, to confirm your selection, press ENTER on the remote control or DHD Controller front panel. The PlasmaWall OSD menus are arranged hierarchically,...
Page 52
Operation 36 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY Figure 4-1. PlasmaWall OSD Menu Structure (continued) Main MenuThe Main Menu is the starting point for accessing all PlasmaWall functions. (You must enter a passcode to access the Calibration and Service menus.) Service Test VideoColor Bars 1 Color Bars 2 Focus Grey Bars Input Names Rename/Restore Remote ControlRemote Code 00, 01, 02 ... 17 ... 31 COMP Key SourceComponent or SCART Display Device - ConfigureInstallationDisplay...
Page 53
Operation PlasmaWall XP Series Installation/Operation Manual 37 PREL IMINARY Input SourceFrom the Main Menu, select Input Source to choose a video signal source. The active source is indicated by an arrow (➡) to its left; in this example, Composite is the active source. Aspect RatioTo change the aspect ratio (size and shape) of the projected image, select Aspect Ratio from the Main Menu and press ENTER. Select the appropriate aspect ratio for your screen size and the type of program material being...
Page 54
Operation 38 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY Table 4-1. Aspect Ratio Settings Aspect Ratio Remote Control Button Description 16:916:9Select 16:9 to view 16:9 DVDs and HDTV programs in their native aspect ratio. 4:3 images are stretched horizontally to fit a 16:9 screen. 4:34:34:3 scales the input signal to fit in the center of the 16:9 screen. 4:3 is the aspect ratio used by computer monitors, standard television programming and most VHS video...
Page 55
Operation PlasmaWall XP Series Installation/Operation Manual 39 PREL IMINARY CinemaCINEMASelect Cinema to view 2.35:1 source material on a 16:9 screen. The upper and lower portions of the screen are masked, but the geometry of the active image area is not changed. Virtual CinemaSVCA 2.35:1 image is stretched anamorphically in both directions to fill a 16:9 display area. The 2.35:1 image is cropped on all sides. Native(none)Select Native to display the source signal in its native...
Page 56
Operation 40 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY PictureUse the controls in the Picture Menu to calibrate your PlasmaWall for optimum picture quality. The PlasmaWall has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards...
Page 57
Operation PlasmaWall XP Series Installation/Operation Manual 41 PREL IMINARY PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes. Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that: The darkest black bars disappear into the background. The dark gray areas are barely visible. The lighter gray areas are clearly visible. The...
Page 58
Operation 42 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4. Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint 1. Press the MENU button on the remote control or DHD Controller front panel. 2. Select Service from the Main Menu and press ENTER. 3. Enter the Service menu passcode. 4. Select Display Device from the Service menu and press ENTER....
Page 59
Operation PlasmaWall XP Series Installation/Operation Manual 43 PREL IMINARY 11.Adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue: Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. When tint is decreased, the image appears redder; when it is increased the image appears greener. To adjust the tint, enable “blue only” display mode in the Diagnostics menu, as you would for adjusting color...
Page 60
Operation 44 PlasmaWall XP Series Installation/Operation Manual PREL IMINARY Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness...