Page 171

 
SM 3-21 B230/B237/D042 
Replacement 
Adjustment 
 
13.  Release the clamp [J] (
 x 1). 
14.  Remove the pulley [K]. 
15.  Hold down the snap [L], and then slid e the exposure lamp [M] to the front side. 
16.  Exposure lamp [M] 
Reassembling 
 
ƒ  Run the cable so there is no slack. Sli de the clamp [A] to adjust the cable slack. 
3.5.4 SCANNER MOTOR 
 
1.  Rear cover (
 Rear 
Cover) 
2.  Scanner motor assembly [A] 
(
 x 2,   x 1, spring x 1) 
3.  Scanner motor [B] (
 x 2) 
4.  After you replace the...

Page 172

 
B230/B237/D042 3-22 SM 
3.5.5  SENSOR BOARD UNIT (SBU) 
 
1.  Exposure glass (
 Exposure Glass) 
2.  SBU cover bracket [A] (
 x 9) 
3.  Original length sensor bracket [B] (
 x 1,  x 1) 
 
4.  Sensor board unit [C] (
 x 5,  x 2,  x 2) 
When reassembling 
Adjust the following SP modes afte r you replace the sensor board unit: 
ƒ  SP4–008 (Sub Scan Mag): See I mage Adjustment:  Scanning. 
ƒ  SP4–010 (Sub Mag Reg.): See  Image Adjustment:  Scanning. 
ƒ  SP4–011 (Main Scan Reg): See  Image Adjustment:...

Page 173

 
SM 3-23 B230/B237/D042 
Replacement 
Adjustment 
ƒ  SP4–688 (DF: Density Adjustment ): Use this to adjust the density level if the ID of 
outputs made in the DF and Platen mode is different. 
3.5.6  EXPOSURE LAMP STABILIZER 
 
1.  Rear cover (
 Rear Cover) 
2.  Exposure lamp stabilizer [A] (
 x 2,  x 2) 
3.5.7  FRONT SCANNER WIRE 
 
1.  Exposure glass (
 Exposure Glass) 
2.  Front frame (
 Exposure Lamp) 
3.  Front scanner wire clamp [A] 
4.  Front scanner wire bracket [B] (
 x 1) 
5.  Front scanner...

Page 174

 
B230/B237/D042 3-24 SM 
Reinstalling the Front Scanner Wire 
 
1.  Position the center ball [A] in the middle of the forked holder. 
2.  Pass the right end (with the ball) [B] through the square hole. Pass the left end 
(with the ring) [C] through the notch. 
3.  Wind the right end counterclockwise (sho wn from the machine’s front) five times. 
Wind the left end clockwise twice.   
 
ƒ  The two red marks [D] come together when you have done this. Stick the wire 
to the pulley with tape. This lets you...

Page 175

 
SM 3-25 B230/B237/D042 
Replacement 
Adjustment 
ƒ  Do not attach the pulley to the s haft with the screw at this time. 
5.  Insert the left end into the slit [F]. The end should go via the rear track of the left  pulley [G] and the rear track of the movable pulley [H]. 
 
6.  Hook the right end onto the front scanner wire bracket [I]. The end should go via 
the front track of the right pulley [J] and the front track of the movable pulley [K]. 
 
ƒ  Do not attach the scanner wire bracket with the screw...

Page 176

 
B230/B237/D042 3-26 SM 
12.  Install the scanner wire clamp [T]. 
13.  Pull out the positioning pins.   
14.  After you replace the wire, do the adjustments in the following section of the 
manual: Image Adjustment – Scanning. 
 
ƒ  Make sure the 1st and 2nd carriages move smoothly after you remove the 
positioning pins. Do steps 8  through 13 again if they do not. 
3.5.8 REAR SCANNER WIRE 
Reinstalling the Rear Scanner Wire 
 
1.  Position the center ball [A] in the middle of the forked holder. 
2....

Page 177

 
SM 3-27 B230/B237/D042 
Replacement 
Adjustment 
be the same as the winding on the three pu lleys at the front. This must show 
as a mirror image. 
Example: At the front of the machine, t he side of the drive pulley with the three 
windings must face the front of the machine. At the rear of the machine, it must face 
the rear. 
6.  Do steps 7 through 13 again in the “” Section. 
3.5.9  TOUCH PANEL PO SITION ADJUSTMENT 
 
ƒ  It is necessary to calibrate t ouch panel at the following times: 
ƒ  When you...

Page 178

 
B230/B237/D042 3-28 SM 
8.  Touch [#] Exit on the screen to close the Self-Diagnostic menu. Save the 
calibration settings.    

Page 179

 
SM 3-29 B230/B237/D042 
Replacement 
Adjustment 
3.6 LASER OPTICS 
 
ƒ  Turn off the main switch and unplug t he machine before beginning any of the 
procedures in this section. Laser  beams can cause serious eye injury. 
3.6.1  CAUTION DECAL LOCATION 
Caution decals are 
placed as shown at 
the right. 
 
 
 
 
 
 
 
 
 
 
 
 
ƒ  Be sure to turn off the main switch  and disconnect the power plug from the power 
outlet before beginning any disassembly or  adjustment of the laser unit. This 
copier uses...

Page 180

 
B230/B237/D042 3-30 SM 
Preparing the new laser optics housing unit 
 
1.  Shutter [A] of the laser optics housing unit (
 x 3) 
 
2.  Polygon motor cover [B] of the laser optics housing unit (
 x 4) 
3.  Sponge padding [C] 
4. Tag [D] 
5.  Reinstall the polygon motor cover [B]. 
Before removing the old laser optics housing unit 
Do the following settings before removing  the laser optics housing unit. These are 
adjustments for skew adjustment moto rs in the laser optics housing unit. 
1.  Plug in and...
Start reading Ricoh Mp C3000 Service Manual