Page 181
SM 3-31 B230/B237/D042 Replacement Adjustment 7. Turn off the main power switch and disconnect the power cord of the copier. Recovery procedure for omitting the “Before removing the old laser optics housing unit” procedure (See page 3-30) If you did not do the procedure in ‘Before removing the old laser optics housing’ before removing the old laser optics housing unit, you must do the following. 1. Turn off the main power switch and disconnect the power cord of the copier. 2. Remove the...
Page 182
B230/B237/D042 3-32 SM 2. Harness cover bracket [B] ( x 4). 3. Rear fan bracket [C] for the laser housing optics unit ( x 3, x 7) 4. Front fan bracket [D] for the laser housing optics unit ( x 2) 5. Remove the old laser optics housing unit [E] ( x 2, x 2)
Page 183
SM 3-33 B230/B237/D042 Replacement Adjustment Installing a new Laser Optics Housing Unit ƒ A new laser optics housing unit has a bra cket to protect the LD units. When you replace the laser optics h ousing unit, use caution. 1. Push the new laser optics housing unit [A] slowly into the copier until the bracket [B] bumps against the frame of the copier. 2. Remove the bracket [B], and then push the new laser optics housing unit fully into the copier ( x 2, All x ). 3. Reassemble the...
Page 184
B230/B237/D042 3-34 SM main scan magnification adjustment with SP2-185-001. ƒ The value [A] is different for each laser optics housing unit. 2. Print the test pattern (14: 1-dot trimming pattern in the SP2-109-003). 3. Check that the left and right trim marg in is within 4 ± 1 mm. If not, change the standard value for the main scan magnification adjustment. 3. Adjust the main scan registration only for the black (Bk). 1. Input the registration value [B] provided with a new laser optics...
Page 185
SM 3-35 B230/B237/D042 Replacement Adjustment 3. Polygon mirror motor cover [B] of the laser optics housing unit ( x 4) 4. Polygon mirror motor holder [C] ( x 2) 5. Polygon mirror motor [D] ( x 4, x 1) After installing the laser optics housing unit: 1. Do the Forced Line Position Adj. Mode c (SP2-111-3). 2. Then do the Forced Line Position Adj. Mode a (SP2-111-1). To check if SP 2-111-1 was successful, wa tch the screen during the process. A message is displayed at the end. Also,...
Page 186
B230/B237/D042 3-36 SM 3.7 IMAGE CREATION 3.7.1 PCU ƒ Do not touch the OPC drum. Do not le t metal objects touch the development sleeve. 1. Open the front door. 2. Lever lock [A] ( x 1) 3. Turn the release lever [B] and the image transfer unit contact lever [C] counter-clockwise. 4. Open the drum positioning plate [D]. 5. Pull out the PCU (hold the grip while you pull it out) [E]. 3.7.2 DRUM UNIT A ND DEVELOPMENT UNIT The new drum unit has a front cover and a front joint....
Page 187
SM 3-37 B230/B237/D042 Replacement Adjustment And use them for reassembling the new drum unit and development unit. 1. If you install a new drum unit, set SP 3902-xxx to 1. Black: 3902-009 Yellow: 3902-010 Cyan: 3902-011 Magenta: 3902-012 ƒ If you do this, then the machine will reset the PM counter for the drum unit automatically, after you turn the power on again. 2. Turn the machine power off. 3. PCU ( PCU) 4. Front cover [A] ( x 2) ƒ Do not touch the bearing [B] after...
Page 188
B230/B237/D042 3-38 SM Note: Remove the toner duct [G] first to avoid breaking it during this procedure . 5. Remove the bushing [C] of the developm ent roller at the rear of the PCU ( x 1). 6. Remove the front joint [D] ( x 1, x 1). ƒ The front joint [D] is firmly set. Remove it with a watchmaker’s or jeweller’s screwdriver. 7. Drum unit [E] and Development Unit [F] [ G ]
Page 189
SM 3-39 B230/B237/D042 Replacement Adjustment ƒ When the development unit is remove d from the drum unit, clean the entrance mylar [G] with a vacuum. 8. If you change the development unit, do the ACC procedure. Developer 1. Set SP 3902-xxx to 1. Black: 3902-005 Yellow: 3902-006 Cyan: 3902-007 Magenta: 3902-008 2. Turn the machine power off. 3. Development unit ( Drum Unit and Development Unit) 4. Hopper cover [A] (hook x 3) 5. Shake a bag of developer and pour it into...
Page 190
B230/B237/D042 3-40 SM PM counter for the developer. (For details of the developer initialization result, see Developer Initialization Result in the Troubleshooting chapter. 8. Do the ACC procedure. 3.7.3 TONER COLL ECTION BOTTLE If you will install a new bottle, and the old bottle is not in a full or near-full condition, then set SP 3902-017 to 1. ƒ If you do this, then the machine will reset the PM counter for the bottle automatically, after you turn the power on again. ƒ If the...