Home > Christie > Projector > Projector Christie Rpmsp D180u User Manual

Projector Christie Rpmsp D180u User Manual

Here you can view all the pages of manual Projector Christie Rpmsp D180u User Manual. The Christie manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 81

Section 4: Advanced Configuration and Controls
RPMSP-D132U & RPMSP-D180U User Manual User Manual4-13020-100245-03  Rev. 1  (11-2010)
4.9.6 Color Wheel Calibration — Submenu
Adjusts the timing of the color wheel. If the color wheel is incorrectly calibrated, the colors throughout the 
displayed image will appear in various unmatched shades.
This adjustment is required whenever the color wheel is replaced. To calibrate the color wheel:
1. From the Diagnostics and Calibration menu, access Color Wheel...

Page 82

4-14RPMSP-D132U & RPMSP-D180U User Manual User Manual020-100245-03  Rev. 1   (11-2010)
Section 4: Advanced Configuration and Controls
4.10 Working With the Lamp
The RPMX/RPMSP-D132U projectors are installed with two132W UHP lamps and the RPMSP-D180U 
projectors are installed with two 180W UHP lamps. Only one lamp will be ON at any given time.
4.10.1 The Lamp Menu
The Lamp menu provides performance adjustments for the lamp to achieve the brightest, most uniform image 
for the life of the lamp. From this...

Page 83

Section 4: Advanced Configuration and Controls
RPMSP-D132U & RPMSP-D180U User Manual User Manual4-15020-100245-03  Rev. 1  (11-2010)
• power the lamp with a specific wattage
Use the lamp mode that best suits your brightness needs. For example, in a tiled display application you may 
want to precisely match brightness levels between adjacent images – judge by eye and set each individual lamp 
“Power” setting as necessary. Or you may want images to be as bright as possible – choose “Max Brightness”....

Page 84

4-16RPMSP-D132U & RPMSP-D180U User Manual User Manual020-100245-03  Rev. 1   (11-2010)
Section 4: Advanced Configuration and Controls
FIGURE 4-18 MORE LAMP OPTIONS
4.11 PIP and Seamless Switching
PIP (Picture-in-Picture) and Seamless Switching are independent but related projector features that utilize two 
image-processing paths within the projector. 
PIP, double processing allows you to display two different images simultaneously, typically a smaller 
“secondary” image within a large “primary”...

Page 85

Section 4: Advanced Configuration and Controls
RPMSP-D132U & RPMSP-D180U User Manual User Manual4-17020-100245-03  Rev. 1  (11-2010)
NOTE HD interlaced sources are not recommended for the PIP window.
Other PIP or Seamless Switching tips include:
• When using two digital signals or one analog and one digital, each must be 165 megapixels/sec. 
• When using two analog signals, each must be 90 megapixels/sec.
• Avoid using an interlaced source in the PIP window
• Seamless switching may affect image quality...

Page 86

4-18RPMSP-D132U & RPMSP-D180U User Manual User Manual020-100245-03  Rev. 1   (11-2010)
Section 4: Advanced Configuration and Controls
Short cut: Press   on the Remote if menu not present.
Toggle to display from two sources at once (Picture-in-Picture) or the primary source only. This checkbox 
turns the secondary source on and off.
 
NOTE: Disable PIP and Best Switching for Interlaced sources > 35kHz.
PIP Size and Position – 
Submenu
Most controls in the PIP Size and Position menu adjust the PIP...

Page 87

Section 4: Advanced Configuration and Controls
RPMSP-D132U & RPMSP-D180U User Manual User Manual4-19020-100245-03  Rev. 1  (11-2010)
Tips:
• Make sure a channel is configured for each source.
• Progressive digital and analog sources are recommended.
• Set Image Optimization to Seamless Switching (see below).
• For best results, use the same frame rate and gamma setting for each.
NOTE: Avoid using two Interlaced sources.
Image Optimization
Use this setting to choose what is more important, image quality...

Page 88

4-20RPMSP-D132U & RPMSP-D180U User Manual User Manual020-100245-03  Rev. 1   (11-2010)
Section 4: Advanced Configuration and Controls
in this manner all of the time, even with single displays. For normal keypad function, select Never (default). 
Set to When PIP Active to activate number keys only when PIP is in use.
NOTE: Numbers Select Main Image keypad functionality works only when menus are closed.
4.12 Status Menu
The read-only Status menu lists a variety of details about the standard and optional...

Page 89

Section 4: Advanced Configuration and Controls
RPMSP-D132U & RPMSP-D180U User Manual User Manual4-21020-100245-03  Rev. 1  (11-2010)
4.14.2 Color Adjustment Procedure
After the Color Primary Settings are calibrated for the site (see Section 4.14.1 Preliminary Calibration), use 
the Color Adjustments by X,Y or Color Saturation menu to refine each projector’s fundamental colors. The hue 
and intensity of each color must appear the same from one display to another. Once matched, you will have 
created a...

Page 90

4-22RPMSP-D132U & RPMSP-D180U User Manual User Manual020-100245-03  Rev. 1   (11-2010)
Section 4: Advanced Configuration and Controls
FIGURE 4-21 COPY X/Y VALUES INTO ALL PROJECTORS
6. In each projector, judge by eye and adjust x/y coordinates slightly in the following manner:
• To match reds, decrease “ Red X” until full field red screens match. 
• To match greens, decrease “Green Y” until full field green screens match.
• To match blues, increase both “Blue X” and “Blue Y” until full field blue screens...