Page 11
-9- 16. Function Button (FUNCTION) This button is used to display the VCR playback picture with the camera pictures on the multiscreen monitor. During the setup, this button is used to select the next page. 17. Auto/Increment Button (AUTO / + ) This button is used to activate the auto panning function. During the setup, this button is used to select the desired parameter in the setup menu. 18. Home/Decrement Button (HOME / – ) This button is used to move the camera to the home position. During the setup,...
Page 12
-10- INSTALLATIONS The installations described below should be made by qualified service personnel or system installers. Installing the WV-PB6164 Data Multiplex Boards When controlling the camera with the multiplexed control data by connecting a coaxial cable, the WV- PB6164 Data Multiplex Board must be installed in the Video Multiplexer. Four data multiplex boards are included with the WJ-FS616 for cameras 1 to 4. Please note that additional multiplex boards are available for purchase as model...
Page 13
-11- CH9 - CH16 CH1 - CH8 6. Set the jumper connector, located at the top left of the board to be installed, to the position shown below. 7. Insert the board and confirm that the position is cor- rect. Then push it in straight. 8. After installing the boards, secure them by tighten- ing the screws and knobs shown above. Note:Some settings for the VD2 signal and control data will be necessary from the setup menu of the Video Multiplexer. Refer to Cable Compen- sation/VD2/Data Setup on page 34 for...
Page 14
-12- Dip Switch Setting Alarm Output Setting 1. Disassemble the video multiplexer as described for installing the Data Multiplex Boards on page 10. 2. Set switches (SW3/SW4/SW5) on the board to choose the alarm control signals as either Open Collector (O.C) or Pulse (0/5V). Open Collector (O.C): 16V DC 100 mA max. Pulse (0/5V): +5V DC approx. 500 ms The above switch positions are the initial factory settings. 0/5V O.C SW5 0/5V 0/5VSW3 O.CSW4 O.C SW3 : Alarm Output SW4 : Alarm Reset Output SW5 :...
Page 15
-13- WV-CU550A System Controller Modifying the Front Panel 1. Peel the tape off the supplied panel templates, then attach them on the front panel of the System Controller. 2. Peel off the label and attach it on the rear of the System Controller as shown below. CONTROLLER ON MODE OFFINOUTTERMON OFF DATA0123456789CONTROLLER UNIT NO. 1-8 Connection with Video Multiplexer (WJ-FS616)TERM. MODEON OFF0OFF ON WJ-FS616 Video Multiplexer Mounting in the Rack 1. Remove the four rubber feet by removing the four...
Page 16
-14- Basic System Connection SYSTEM CONNECTIONS 481216 371115 261014 15913 PUSH OPEN16 POWERLOCKON OFF ALARMMULTI SCREENMULTISCREENSELECT RESET SPOT SEQUENCE VCR CAMCAMERA/PRESET POSITION Video Data RS-485 Video Multiplexer WJ-FS616 Time Lapse VCR Personal Computer (Software) System Controller WV-CU550ASpot Monitor Live 1-16chMultiscreen Monitor Live 1-16ch Playback 1-16ch RS-232C/WiredAlarm Sensor AUXAlarm 123456789MON CAM0System Controller for WJ-FS616 F3F4F2F1 Shown below is an example of a basic...
Page 17
-15- CAMERA IN CAMERA OUT 16 15 14 13 5 4 3 2 1 16 15 14 13 5 4 3 2 1 A B TA B RG N DG N D RS485 AUXAlarm Video Multiplexer WJ-FS616 Connection with the Camera Sites Connect cameras (or camera site equipment) data multiplexed type to the CAMERA IN connectors 1 through 4 on the rear panel of the Video Multiplex- er. Note:Make sure that the cable length between the camera site and the WJ-FS616 Video Multi-plex- er is less than 900 m (3 000 ft) when using RG- 59/U, BELDEN 9259 or equivalent cables....
Page 18
-16- Connections for RS-485 type camera There are two options to connect the camera with the Multiplexer, depending on the distance between them. For data multiplexed type cameras, a maximum dis- tance of 900 meters (3 000 ft) is the limit for using coaxial cable such as RG-59/U, BELDEN 9259 or equivalent. If more distance is required, use cameras and Multiplexers with RS-485 communication feature. This will lower signal loss and extend the distance as video signal and data are transmitted...
Page 19
-17- Connection with the Monitors Connect the Monitors to the Spot Output (SPOT OUT) Connector and Multiscreen (MULTISCREEN) Connector on the rear of the Video Multiplexer. Connection with the WV-CU550A System Controller If the supplied 6-conductor cable assembly is used, simply plug one end of the cable into the DATA IN port of the Video Multiplexer and the other end into DATA OUT port on the System Controller. If you use cables assembled from locally procured materials, it is important that only high...
Page 20
-18- Connection with Alarm Sensors Connect the sensor switches to the Alarm/Remote (ALARM/REMOTE) Control Connector on the rear of the Video Multiplexer as shown in the example below. 37 19 20 1 SW2 SW1 SW16 GND ALARM/REMOTE1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Function Electronic Zoom Sequence Spot Alarm/Remote Select Input Sequence SW for Spot Output Not Used Alarm Recover Input Alarm Output Alarm 16 Alarm 14 Ground Alarm 11 Alarm 9 Alarm 8 Alarm 6 Ground Alarm 3 Alarm 1 Pin No....