Home > Panasonic > Recorder > Panasonic Network Camera Recorder With Viewer Software BB-HNP15A Operating Instructions

Panasonic Network Camera Recorder With Viewer Software BB-HNP15A Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Network Camera Recorder With Viewer Software BB-HNP15A Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Operating Instructions
    111
    4.Click [Yes].
     After you restart the program, it will operate as a remote server.
    Note
     Available functions differ for administrator privileges and general user privileges (see 
    page 114).
     You cannot use remote access until  you configure the administrator or 
    general user settings.
     Clear the [Use Remote Access Connection] check box to use the program as  a normal recording software.
     To use remote access via the Internet, configure a port for port forwarding. For details on configuring port forwarding, see your routers documentation.
    SettingDescription
    Use Remote 
    Access ConnectionSelect this check box when you are using remote access 
    functions.
    Select [Operate as a server] to use as a remote server.
    Server SettingsPort  
    Enter a port number. (Enter a number from 1 to 65535, except 
    for 10081. Default is 10082.)
     Admin User Name/Admin Password
    Enter the user name and password to use for administrator 
    privileges (4 to 15 alphanumeric characters).
     User Name/User Password
    Enter the user name and password to use for general user 
    privileges (4 to 15 alphanumeric characters). 
    						
    							Operating Instructions
    11 2
    [Remote Client Settings (remote client function)]
    Configure the following settings after inst alling this software on a PC to be used as 
    a remote client.
    1.Select [Remote Access]  [Settings] on the menu bar.
    2.Select the [Use Remote Access Connection] check box on the [Settings] 
    screen.
    3.Select [Operate as a client] and click [OK].
    4.Click [Yes].
     After you restart the program, it will operate as a remote client.
    Note
    When operating as a remote client,  is not displayed in the notification area.  
    						
    							Operating Instructions
    11 3
    [New Connection (remote client function)]
    1.Select [Remote Access]  [New Connect] on the menu bar.
     Click [Register] to register a remote server.
    Click [Change] to change remote server settings.
    Click [Delete] to remove remote server settings.
    Click [Search] to search fo r remote server settings.
     You can register up to 1000 remote servers.
    2.Click [Register].
    3.Enter the Server Name, Server Address (IP address or domain name) and the 
    port number of the remote server, and click [OK].
    4.Click [Connect]. 
    						
    							Operating Instructions
    11 4
     The [Remote Access Authentication] page will be displayed when the remote server connection is successful.
    5.Enter the user name and password configured for the remote server and click 
    [OK].
     If you enter the administrator name and password, the client connects a remote server with administrator privileges. If you enter the general user 
    name and password, the client connects a remote server with general user 
    privileges. See the following table for differences between administrator and 
    general user privileges.
    Note
     The first time you connect to a remote server, the remote client registration 
    code is automatically registered on the client control page of the remote 
    server.
     Only one remote client can be connected to a remote server at a time. You cannot connect to a remote server if another client is already connected.
     
    An error message is displayed if you try to connect to a remote server if 
    another client is connected.
     Use the same version of the software in the remote server and remote client.
    Functions available for remote access
    Function nameAdministrator  privilegesUser 
    privilegesSimultaneous  launch
    *1
    Multi-Monitoring
    Camera ImageOOO
    Change the camera layoutOXX
    Change the Image display formatOXX
    Switch pageOOO
    Start/stop recording OXO
    Camera operationsOOO
    Audio muteOOO
    Enable/disableOXX 
    						
    							Operating Instructions
    11 5
    *1Indicates which functions can and cannot be on a remote server and the remote 
    client at the same time.
    *2User-specified folders cannot be searched.
    *3You cannot perform file conversion, but you can download recorded images (see 
    page 118).
    Multi-Playback
    Playback, Stop, etc. OOO
    Change the camera layoutOXO
    Change the Image display formatOXX
    Recorded Images
    Search∆*2∆*2O
    ConversionX*3X*3X
    CopyingOXX
    Delete filesOXX
    Change the keywordOXX
    Image information displayOOO
    Settings
    Basic Settings (Destination Folder)XXX
    Basic Settings (Destination Hard Disk Space)OXX
    Basic Settings (Limit the destination 
    recording capacity
    )
    OXX
    Basic Settings (Connection method to the 
    camera
    )
    OXX
    Proxy server settingsOXX
    Multi-MonitoringOXX
    Multi-PlaybackOXX
    NavigationOXX
    Operation Support (Restore Program)XXX
    Operation Support (Log Analysis)OXX
    Add/delete camerasOXX
    Add/delete timersOXX
    Import/ExportOXX
    Function nameAdministrator   privileges User 
    privileges Simultaneous 
    launch
    *1 
    						
    							Operating Instructions
    11 6
    Note
     When settings pages are displayed on the remote server, a remote client cannot use administrator privileges  to connect to the settings pages.
     If a connection reset is connected after connecting to a remote server, the 
    following message will be displayed.
     Click [Yes] to reconnect. Processing continues if the reconnection is successful.
     If you click [No], the unconnected  multi-monitoring page is displayed. 
    						
    							Operating Instructions
    11 7
    [Delete a Remote Client (remote server function)]
    Delete a remote client that was registered automatically.
    1.Select [Remote Access]  [Client Control] on the menu bar.
    2.Select clients you want to delete on the [Client Control] page, and click 
    [Delete]. 
    3.Click [OK].
    Note
     You can register up to 999 remote clients.
     Duplicate registration codes  cannot be registered.
     To change information for a remote client, select the remote client and click 
    [Change]. After you have modified the information in the settings page, click 
    [OK].
     In the Status column, the connection  status (Connected/Unconnected) is 
    displayed. You can see which client is connected. 
    						
    							Operating Instructions
    11 8
    [Download Recorded Images (remote client function)]
    Download recorded images from the remote server.
    1.Select the images that you want to download in [Playback list].
     See page 92 for how to display recorded images in [Playback list].
     To select multiple images, click the images while pressing [Ctrl] key.
    2.Select the [Download] from the editing menu and click [Execute].
     Available functions differ for administrator privileges and general user privileges (see 
    page 114) .                                                                                                        
    The above screen is displayed when connected with administrator 
    privileges.
    3.To specify a time frame, set start time and end time, and click [OK]. 
     If you do not set a time frame, all selected images will be converted.
     If multiple recorded images are select ed, you cannot specify the time frame. 
    						
    							Operating Instructions
    11 9
     The save as window is displayed.
    4.Select the destination folder, enter a file name and click [Save].
    5.Click [Start].
     Conversion will begin on the remote server.
     Download will begin on the remote client.
     When the download has completed successfully, the following window is 
    displayed.
     When you select multiple recorded images, start time and end time are not displayed.  
    						
    							Operating Instructions
    120
    [Analyzing Remote Server Logs (remote client function)]
    During remote access, the following menus are added to the log type in the 
    operation support page (see 
    page 131):
     System Log (server)
     Operation Log 1 (server)
     Operation Log 2 (server)
     Restore Log (server)
    Select when analyzing remote server logs.
    1.Select [Window]  [Settings] on the menu bar.
    2.Select [Preferences]  [Operation Support].
    3.Select the date of the logs to analyze, log type.
    4.Click [Execute Log Analysis].
    5.Click [Start Download].
     Start downloading.
     When the download completes, a log analysis result will be displayed. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Network Camera Recorder With Viewer Software BB-HNP15A Operating Instructions