Operating Instructions [For assistance, please call: 1-800-272-7033] 71 Non Transfer mode Non Transfer mode enables[Start Capture]on the operation bar to buffer the image on the Single Camera screen. Refer to page 50. Capture Control can lock [Start Capture]on the operation bar to prevent the user from capturing the Buffered Image. Click[ClearBuffered images]to clear the buffered image. [ClearBuffered images]does not save the parameters. 1.Click[Image Transfer]on Setup Page. 2.Select the each parameter. Click[Save]when finished. Click[Cancel]to quit the current settings. The window returns to Setup Page without saving the parameters.
Operating Instructions 72 Transfer in the Alarm Mode TheAlarmmodecantransferanimageviae-mailorFTPwhenthealarmtrigger is active. To activate the alarm trigger, the External Sensor Input of External I/O must be connected with the external sensors/devices. The Alarm mode can send the e-mail without transferring the image. The Alarm mode uses the Network Camera internal clock. Make sure Date and Time has been configured. Refer to page 62 about Date and Time. 1.Click[Alarm]onImage Transfer window. c. b. a. d. e. f.
Operating Instructions [For assistance, please call: 1-800-272-7033] 73 Instructions for the data fields a.External Sensor Input of External I/O activates the alarm trigger. Refer to page 106. b.Active Time of Trigger The active trigger time can be set in the primary time and the secondary time. The secondary time is the supplement of the primary time. Always: always activates the alarm trigger. Operational between: Sets the start and stop time of the primary time. The day of the week can be set by checking. Start and stop time is set only in 24 h time mode. Alarm enable condition: Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O. c.Secondary timeis active trigger time except the primary time. Alarm enable condition: Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O. d.Sets theimage resolutionandimage quality. Image resolution: 640 x 480/320 x 240/160 x 120 Image quality: Favor Clarity/Standard/Favor Motion e.The Pre or Post trigger or both can be set on the Buffered Image. Check the box. f.Image Frequency: Sets the interval to send the image. Maximum number of images per each trigger: Selects the number of buffering frames from numbers 1 to 3000.
Operating Instructions 74 a.SelectsTransfer Method. Non Transfer without Memory Over Write: Image buffering will stop when the internal memory is full. Non Transfer with Memory Over Write: Buffered image will overwrite the older image data when the internal memory is full. FTP: Enters the server address* 1or Host Name*2, Port Number (1— 65535), Login ID*2and password*2to access the FTP server and upload file name*2including full path. Time in 24 h mode is attached on theuploadfilename. Login timing: [Every Time] or [One Time] can be selected. When selecting [Every Time], Network Camera repeats logging in and out with each transfer of one image. When selecting [One Time], Network Camera stays logged in until the transfer of all images is completed. Select [One Time] when transferring many images in short duration time. a. b. c.
Operating Instructions [For assistance, please call: 1-800-272-7033] 75 Over write setting: Selects [Over Write...] to overwrite the transferred image or [Add time...] to save each transferred image. Data transfer method: Use [Passive Mode] normally. If FTP does not work properly, ask your ISP or network administrator about the transferring mode of FTP server. [Passive Mode] or [Active Mode] is available. b.Mail: Sets the SMTP and POP3 server address*1or Host Name*2, Login ID*2and Password*2. From (Reply)*3: Enter the e-mail address of [Reply-to]. [To] can be the same address as From (Reply). To * 3: Enter the e-mail address of receiver. Subject & Text *4: Sets the subject and text of the e-mail. Timein24hmodeisattachedonthesubject. Notes Set POP3 server address or Host Name, Login ID and Password if you need POP authentication to send the e-mail. Ask your ISP or administrator. Network Camera will only operate correctly with SMTP (Simple Mail Transfer Protocol) server. It is not available with Internet- accessed mail servers like Hotmail ® or other mail accounts accessed via web browser. c.Select [No Message] or [Mail] Mail: Only the notification e-mail is sent when the alarm trigger is active. Refer tob. Mailfor each parameter. * 1Refer to IP addressing on page 108. *2Refer to unavailable character set 1 on page 108. *3Refer to unavailable character set 2 on page 108. *4Only [] is unavailable in the ASCII character table on page 108 and refer to displayable character set on page 109. 2.Select/Enter the each parameter. Click[Save]when finished. Click[Cancel]to quit the current settings. The window returns to Setup Page without saving the parameters. Click[ClearBuffered images]to clear the buffered image. [ClearBuffered images]does not save the parameters.
Operating Instructions 76 Setting Example b.a. c. d. e. f.
Operating Instructions [For assistance, please call: 1-800-272-7033] 77 Setting explanation a.The active time of trigger is set between 9:00 AM to 6:00 PM from Monday to Friday. When the alarm occurs in the setting time, the images are transferred to FTP server, and the notification is sent to the specified user via e- mail. The alarm trigger is on when the sensor signal is changed to the [Rising] (GND to Open High) of External Sensor Input of External I/O. b.The secondary time is set inactive. c.The transferring image size is 160 x 120, and the image quality is standard. d.Enables the Pre-alarm and Post-alarm Image Buffering: Network Camera will transfer Pre-alarm 10 images by one image per minute and Post-alarm 20 images by one image per second when detecting the alarm trigger. e.Setting of FTP server: IP Address — 192.168.0.20 Por t No. — 21 Login ID — Panasonic Password — ******** Login timing: Every Time Upload File name — NetworkCamera File name and time stamp is named to the file. (Example: NetworkCamera20030101093000000 .jpg) Underlined numbers are 9 h 30 min 00 s 000 ms on January 1, 2003. Data transfer method — Passive Mode f.SMTP server address — xxx.xxx.com POP3 server address — xxx.xxx.com Login ID — Panasonic Password — ******** Mail is sent to [email protected] from [email protected]. Subject is [Mail Transfer]. Text is [Alarm was generated].
Operating Instructions 78 Transfer in the Timer Mode The timer mode can be activated by entering the active time, the image setting, frequency setting and the transfer method onImage Transfer window.Buffered Image can also be transferred via e-mail or FTP. The timer mode uses the Network Camera internal clock. Make sure Date and Time has been configured. Refer to page 62 about Date and Time. 1.Click[Timer]on Image Transfer window. b. c. d. e. a.
Operating Instructions [For assistance, please call: 1-800-272-7033] 79 Instructions for the data fields a.Buffers or transfers by the timer trigger. b.Active Time of Trigger Always: always activates the timer trigger. The timer trigger interval can be set ine. ImageBuffer Frequency Setting. Operational between: Sets the start and stop time of the primary time. The day of the week can be set by checking. If the setting time passes over midnight, check the check box of only the day of start time. Start and stop time is set only in 24 h time mode. Note The first image is buffered or transferred at the start time. The later images are buffered or transferred at the interval of thee. ImageBuffer Frequency Setting. c.Secondary timeis active except the primary time. The timer trigger interval in the secondary time can be set ine. Image Buffer Frequency Setting. d.Sets theimage resolutionandimage quality. Image resolution: 640 x 480/320 x 240/160 x 120 Image quality: Favor Clarity/Standard/Favor Motion e.Image Frequency: Sets the interval to send the image. Note Short interval of Image Buffer Frequency makes Network Camera transfer the older images. Set the interval long enough to transfer the images. Buffered Image screen enables you to check this setting.
Operating Instructions 80 a.SelectsTransfer Method. Non Transfer without Memory Over Write: Image buffering will stop when the internal memory is full. Non Transfer with Memory Over Write: Buffered image will overwrite the older image data when the internal memory is full. [Primary]or[Secondary]on the operation bar can be displayed to view the Buffered Image screen in Non Transfer setting. FTP: Enters the server address* 1or Host Name*2, Port Number (1— 65535), Login ID*2and password*2to access the FTP server and upload file name*2including full path. Time in 24 h mode is attached on theuploadfilename. Login timing: [Every Time] or [One Time] can be selected. When selecting [Every Time], Network Camera repeats logging in and out with each transfer of one image. When selecting [One Time], Network Camera stays logged in until the transfer of all images is completed. Select [One Time] when transferring many images in short duration time. a. b.