Home > Panasonic > Camera > Panasonic Network Camera Kx Hcm270 Operating Instructions

Panasonic Network Camera Kx Hcm270 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Network Camera Kx Hcm270 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 61
    File sizeoftheimage
    The internal memory, image resolution, image quality and object situation
    determine the maximum number of frames. File sizes change depending on the
    image quality and object situation. (Brightness, etc.)
    For example, the image size per frame in the image resolution is as follows. (When
    the image quality is Standard)
    160 x 120: about 2.7 Kbytes (22 Kbits)
    320 x 240: about 10 Kbytes (80 Kbits)
    640 x 480: about 18 Kbytes (144 Kbits) DDNS
    YourE-mail
    Address
    Personal
    (Camera) URL
     Your Account
    Link If your ISP specified IP address of Cable/xDSL modem
    is not static, you need to contract to DDNS (Dynamic
    Domain Name System) service.
    Check DDNS Enable, enter Your E-Mail Address and
    refer to an attached leaflet for DDNS service.
     By enabling DDNS serviceviewnetcam.com,youcan
    create a personalized web address (for example,
    bob.viewnetcam.com) at which your cameras live video
    can always be found on the Internet. The E-Mail address
    you entered will be automatically informed to
    viewnetcam.comfor managing and supporting your
    account, improving services, and for marketing and
    promotional purposes.
     Refer to unavailable character set 2 in page 108 for the
    e-mail address.
    Max. Bandwidth
    Usage It can restrict the transmit bandwidth.
     Select the max bandwidth usage from 0.1 Mbit/s to
    Unlimited Mbit/s.
     Refer to the next File size of the image.
    *
    aIf you automatically get the address from DHCP server, you do not need to set
    up.Instructions for the data fields 
    						
    							Operating Instructions
    62
    3.5.3 Name/Time
    Name/Time windowis used to assign a name to each Network Camera. Date
    and Time entered on Name/Time window are used for the Alarm/Timer mode in
    the Image Transfer feature and on the Buffered Image screen. NTP automatically
    adjusts the internal clock of Network Camera.
    1.Click[Name/Time]on Setup Page.
    2.Enter the Camera Name and Date and Time. Click[Save]when finished.
    Click[Cancel]to quit the current settings. The window returns to Setup
    Page without saving the parameters.
    Instructions for the data fields
    Camera
    NameThe Camera Name appears on the Single Camera screen.
     Refer to unavailable character set 1 on page 108.
     Refer to displayable character set on page 109.
    Date and
    TimeFirst click[AM/PM]or[24H]. The display changes in each time
    mode.
    Note
    Time setting will be affected by the temperature. Time
    setting may lose one minute per month in 25 °C (77 °F)
    condition. It may lose five minutes in a colder or hotter
    condition. Please useAuto Adjustmentfeature when
    Network Camera is installed where the temperature
    changes hugely in daytime and night-time. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 63
    TimeZone
    GMT-10:00 Hawaii
    GMT-09:00 Alaska, Hawaii Daylight Time
    GMT-08:00 Pacific Time, Alaska Daylight Time
    GMT-07:00 Mountain Time, Pacific Daylight Time
    GMT-06:00 Central Time, Mountain Daylight Time
    GMT-05:00 Eastern Time, Central Daylight Time(default)
    GMT-04:00 Eastern Daylight Time
    GMT 00:00 Western Europe Time
    GMT+01:00 Central Europe Time, Middle Europe Time
    GMT+02:00 Eastern Europe Time, Middle Europe Daylight Time
    GMT+03:00 Baghdad
    GMT+08:00 China Time, Western Australia Time
    GMT+09:00 Japan Time
    GMT+09:30 Central Australia Time
    GMT+10:00 Eastern Australia Time
    GMT+10:30 Central Australia Daylight Time
    GMT+11:00 Eastern Australia Daylight TimeInstructions for the data fields
    Date and
    Time TimestampontheBufferedImagescreencanbe
    changed[AM/PM]or[24H].
     Only 24 h time mode is used in the Alarm/Timer mode
    in the Image Transfer feature.
    Auto
    AdjustmentNTP (Network Time Protocol) Server synchronizes Network
    Camera internal clock. It adjusts automatically everyday. Check
    the box to enable NTP.
     NTP Server Address or Host Name
    Ask your ISP or the network administrator for the NTP
    Server.
     Select your Time Zone.
    Note
    Daylight-saving Time (Daylight Time) is not set
    automatically. Select it manually. 
    						
    							Operating Instructions
    64
    3.5.4 Security: Administrator
    Security: Administrator windowallows the administrator to limit or exclude
    access to the selected Network Camera. Individual levels of access can be
    defined for multiple users.
    Notes
     If Network Camera is to be accessed via the Internet, use
    authentication window for security. It will prevent your unauthorized
    person from changing any Network Camera parameters.
     Refer to page 65 for details about authentication security.
    1.Click[Security: Administrator]on Setup Page.
    2.Enter each parameter in the proper data field. Click[Save]when finished.
    Click[Cancel]to leave the current settings unchanged. The window
    returns to Setup Page without saving the parameters.
     Restart to makeSecurity: Administrator windowsettings effective to
    all Motion JPEG viewers. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 65
    Instructions for the data fields
    Authentication
    EnableAuthentication window can be set in the three patterns.
    None: No authentication window appears. Anyone can
    access all screens (Single Camera/Multi-Camera screen)
    and pages (Top Page and Setup Page).
    Administrator only: Authentication window appears when
    accessing Setup Page. Authentication window does not
    appear when accessing Top Page.
    Administrator and General User: Authentication window
    appears when accessing Setup Page for the administrator
    and Top Page for the general user.
    Administrator
    Authentication
    for Setup PageID: Enter the administrator ID.
    ID and Password are case sensitive.
    Password:
    Enter the administrator password. The password should be
    difficult to guess and confidential.
    Refer to unavailable character set 1 on page 108.
    Note
    Assign the ID and password to meet your specific
    security requirements. To maximize its effectiveness,
    keep the following contents.
     Be sure the ID and password are different.
     Make the ID and password as long and random
    as possible.
     Periodically change the password.
    Retype:
    Reenter the password to confirm. Do not copy the text.
    Top PageAdministrator General User Unregistered User
    Setup Page
    : Accessible—: Not accessible—
    —
    Top PageAdministrator General User Unregistered User
    Setup Page
    : Accessible : Not accessible—
    —— — 
    						
    							Operating Instructions
    66
    3.5.5 Security: General User
    Security: General User windowallows the administrator to create the general
    user ID and password for the security level defined as general user. Up to 30
    individual user names can be defined. The various security levels are explained
    on page 65.
    1.Click[Security: General User]on Setup Page.
    2.Enter each parameter in the proper data field. Click[Save]when finished.
    Click[Cancel]to leave the current settings unchanged. The window
    returns to Setup Page without saving the parameters.
     Restart to makeSecurity: General User windowsettings effective to
    all Motion JPEG viewers. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 67
    Instructions for the data fields
    General User
    AuthenticationTheGeneralUsercanbeupto30.Eachofthemcan
    have their own ID and password.
    (1) User ID List User ID List displays the registered user name.
    [Delete]and[Modify]deletes/modifies the general
    user in the list. Select the desired user and click
    [Delete]or[Modify].
    (2) New UserEnter the general user ID, password and reenter the
    password to confirm. The password should be difficult
    to guess and confidential.[Save]registers the new user
    in the User ID List. ID and Password are case sensitive.
    Refer to unavailable character set 1 on page 108.
    Note
    Assign the ID and password to meet your specific
    security requirements. To maximize its
    effectiveness, keep the following contents.
     Be sure the ID and password are different.
     Make the ID and password as long and
    random as possible.
     Periodically change the password. 
    						
    							Operating Instructions
    68
    3.5.6 Top View Image
    Top View Image Setting windowcan change settings for Top Page, Single
    Camera and Multi-Camera screen such as the initial language, the image
    resolution, image quality, refresh interval as the initial setting,Limit time of
    Continuous Motion JPEGandOn the Air time.
    1.Click[To p V i e w I m a g e]on Setup Page.
    2.Select the each parameter. Click[Save]when finished.
    Click[Cancel]to quit the current settings. The window returns to Setup
    Page without saving the parameters.
     Restart to makeLimit Time of Continuous Motion JPEGsettings
    effective to all Motion JPEG viewers.
    Instructions for the data fields
    LanguageSelect the initial language from the list: English (US), English (UK),
    French, German, Italian, Spanish or Japanese. The selected
    language is displayed as the initial language on Top Page, Single
    Camera screen and Multi-Camera screen. All Setup windows are
    also changed when selecting English (US), English (UK) or
    Japanese. English (UK) is displayed on Setup windows when
    selecting French, German, Italian or Spanish. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 69
    Instructions for the data fields
    To p P a g e Top Page title can be changed. Enter the new title.
     Refer to unavailable character set 1 on page 108 but [space]
    is available.
     Refer to displayable character set on page 109.
     Network Camera picture on Top Page can be changed.
    Enter the URL (http://) to display the picture on the specified
    web site.
     Only [space] and [] are unavailable in the ASCII character
    tableonpage108.
     NetworkCamerapictureonTopPagecanbesetthelinktothe
    specified web site. Enter the URL (http://).
     Only [space] and [] are unavailable in the ASCII character
    tableonpage108.
    Image
    Resolution640 x 480(cannot set on the Multi-Camera screen.)
    320 x 240(default)
    160 x 120
    ImageQualityFavor Clarity: Image is optimized for good clarity.
    Standard: Image quality is standard. (default)
    Favor Motion:
    Image is optimized for enhanced motion display.
    Refresh
    IntervalThe refresh interval of JPEG - Regularly Refresh can be selected.
    Select the desired interval.
     10 seconds to 5 minutes
    Limit time of
    Continuous
    Motion JPEGTo make the network traffic smooth, select the duration time to
    display Motion JPEG. When the timer expires, the image changes
    to JPEG - Regularly Refresh.
     10 seconds to Unlimited
    On the Air timeSpecifies the timetable to allow users to access Top View Image
    screen. When you access the image except the specified time, blue
    screen appears.
    Always:Always allows users to access.
    Operational between:
    Specifies the date and time to access the image. 
    						
    							Operating Instructions
    70
    3.5.7 Image Transfer
    Image Transfer windowcan set the Image Transfer feature. Network Camera can
    buffer images and send the images via e-mail or FTP. The request to send the
    image is initiated by a contact closure from the external sensors/devices
    connected to the External I/O using the Alarm mode. The external sensors/
    devices are customer provided. The images can also be sent in the interval of time
    using the Timer mode. Make sure Date and Time has been configured. Refer to
    page 62 about Date and Time.
    Note
    WhenyouuseFTPore-mailintransferringtheimage,youneedtosetDefault
    Gateway and DNS Server address.
    Note
    The Alarm and Timer mode cannot be set at the same time. Non Transfer: Image Transfer feature is not in use.
    Alarm mode: The alarm trigger activates transferring the image. Refer to
    page 72.
    Timer mode: The timer trigger activates transferring the image. Refer to page
    78. 
    						
    All Panasonic manuals Comments (0)