Page 61
Operating Instructions [For assistance, please call: 1-800-272-7033] 61 Instructions for the data fields Authentication EnableAuthentication window can be set in the three patterns. None: No authentication window appears. Anyone can access all screens (Single Camera/Multi-Camera screen) and pages (Top Page and Setup Page). Administrator only: Authentication window appears when accessing Setup Page. Authentication window does not appear when accessing Top Page....
Page 62
Operating Instructions 62 3.5.5 Security: General User Security: General User window allows the administrator to create the general user ID and password for the security level defined as general user. Up to 30 individual user names can be defined. The various security levels are explained on page 61. 1.Click [Security: General User] on Setup Page. 2.Enter each parameter in the proper data field. Click [Save] when finished. •Click [Cancel] to leave the current settings unchanged. The window returns to...
Page 63
Operating Instructions [For assistance, please call: 1-800-272-7033] 63 Instructions for the data fields General User AuthenticationThe General User can be up to 30. Each of them can have their own ID and password. (1) User ID List •User ID List displays the registered user name. •[Delete] and [Modify] deletes/modifies the general user in the list. Select the desired user and click [Delete] or [Modify]. (2) New UserEnter the general user ID, password and reenter the...
Page 64
Operating Instructions 64 3.5.6 Top View Image Top View Image Setting window can change settings for Top Page, Single Camera and Multi-Camera screen such as the initial language, the image resolution, image quality, refresh interval as the initial setting, Limit time of Continuous Motion JPEG and On the Air time. 1.Click [Top View Image] on Setup Page. 2.Select the each parameter. Click [Save] when finished. •Click [Cancel] to quit the current settings. The window returns to Setup Page without saving...
Page 65
Operating Instructions [For assistance, please call: 1-800-272-7033] 65 Instructions for the data fields Top Page•Top Page title can be changed. Enter the new title. •Refer to unavailable character set 1 on page 96 but [space] is available. •Refer to displayable character set on page 97. •Network Camera picture on Top Page can be changed. Enter the URL (http://) to display the picture on the specified web site. •Only [space] and [] are unavailable in the ASCII character...
Page 66
Operating Instructions 66 3.5.7 Image Transfer Image Transfer window can set the Image Transfer feature. Network Camera can buffer images and send the images via e-mail or FTP. The request to send the image is initiated by a contact closure from the external sensors/devices connected to the External I/O using the Alarm mode. The external sensors/ devices are customer provided. The images can also be sent in the interval of time using the Timer mode. Make sure Date and Time has been configured. Refer...
Page 67
Operating Instructions [For assistance, please call: 1-800-272-7033] 67 Non Transfer mode Non Transfer mode enables [Start Capture] on the operation bar to buffer the image on the Single Camera screen. Refer to page 46. Capture Control can lock [Start Capture] on the operation bar to prevent the user from capturing the Buffered Image. Click [Clear Buffered images] to clear the buffered image. [Clear Buffered images] does not save the parameters. 1.Click [Image...
Page 68
Operating Instructions 68 Transfer in the Alarm Mode The Alarm mode can transfer an image via e-mail or FTP when the alarm trigger is active. To activate the alarm trigger, the External Sensor Input of External I/O must be connected with the external sensors/devices. The Alarm mode can send the e-mail without transferring the image. The Alarm mode uses the Network Camera internal clock. Make sure Date and Time has been configured. Refer to page 58 about Date and Time. 1.Click [Alarm] on Image...
Page 69
Operating Instructions [For assistance, please call: 1-800-272-7033] 69 Instructions for the data fields a.External Sensor Input of External I/O activates the alarm trigger. Refer to page 94. b.Active Time of Trigger The active trigger time can be set in the primary time and the secondary time. The secondary time is the supplement of the primary time. Always: always activates the alarm trigger. Operational between: Sets the start and stop time of the primary time. The...
Page 70
Operating Instructions 70 a.Selects Transfer Method. Non Transfer without Memory Over Write: Image buffering will stop when the internal memory is full. Non Transfer with Memory Over Write: Buffered image will overwrite the older image data when the internal memory is full. FTP: Enters the server address* 1 or Host Name*2, Port Number (1— 65535), Login ID*2 and password*2 to access the FTP server and upload file name*2 including full path. Time in 24 h mode is attached on the upload file name. Login...