Operating Instructions [For assistance, please call: 1-800-272-7033] 61 Instructions for the data fields Authentication EnableAuthentication window can be set in the three patterns. None: No authentication window appears. Anyone can access all screens (Single Camera/Multi-Camera screen) and pages (Top Page and Setup Page). Administrator only: Authentication window appears when accessing Setup Page. Authentication window does not appear when accessing Top Page. Administrator and General User: Authentication window appears when accessing Setup Page for the administrator and Top Page for the general user. Administrator Authentication for Setup PageID: Enter the administrator ID. ID and Password are case sensitive. Password: Enter the administrator password. The password should be difficult to guess and confidential. Refer to unavailable character set 1 on page 96. Note Assign the ID and password to meet your specific security requirements. To maximize its effectiveness, keep the following contents. •Be sure the ID and password are different. •Make the ID and password as long and random as possible. •Periodically change the password. Retype: Reenter the password to confirm. Do not copy the text. Top pageAdministrator General User Unregistered User Setup page : Accessible— : Not accessible— — Top pageAdministrator General User Unregistered User Setup page : Accessible : Not accessible— —— —
Operating Instructions 62 3.5.5 Security: General User Security: General User window allows the administrator to create the general user ID and password for the security level defined as general user. Up to 30 individual user names can be defined. The various security levels are explained on page 61. 1.Click [Security: General User] on Setup Page. 2.Enter each parameter in the proper data field. Click [Save] when finished. •Click [Cancel] to leave the current settings unchanged. The window returns to Setup Page without saving the parameters. •Restart to make Security: General User window settings effective to all Motion JPEG viewers.
Operating Instructions [For assistance, please call: 1-800-272-7033] 63 Instructions for the data fields General User AuthenticationThe General User can be up to 30. Each of them can have their own ID and password. (1) User ID List •User ID List displays the registered user name. •[Delete] and [Modify] deletes/modifies the general user in the list. Select the desired user and click [Delete] or [Modify]. (2) New UserEnter the general user ID, password and reenter the password to confirm. The password should be difficult to guess and confidential. [Save] registers the new user in the User ID List. ID and Password are case sensitive. Refer to unavailable character set 1 on page 96. Note Assign the ID and password to meet your specific security requirements. To maximize its effectiveness, keep the following contents. •Be sure the ID and password are different. •Make the ID and password as long and random as possible. •Periodically change the password.
Operating Instructions 64 3.5.6 Top View Image Top View Image Setting window can change settings for Top Page, Single Camera and Multi-Camera screen such as the initial language, the image resolution, image quality, refresh interval as the initial setting, Limit time of Continuous Motion JPEG and On the Air time. 1.Click [Top View Image] on Setup Page. 2.Select the each parameter. Click [Save] when finished. •Click [Cancel] to quit the current settings. The window returns to Setup Page without saving the parameters. •Restart to make Limit Time of Continuous Motion JPEG settings effective to all Motion JPEG viewers. Instructions for the data fields LanguageSelect the initial language from the list: English (US), English (UK), French, German, Italian, Spanish or Japanese. The selected language is displayed as the initial language on Top Page, Single Camera screen and Multi-Camera screen. All Setup windows are also changed when selecting English (US), English (UK) or Japanese. English (UK) is displayed on Setup windows when selecting French, German, Italian or Spanish.
Operating Instructions [For assistance, please call: 1-800-272-7033] 65 Instructions for the data fields Top Page•Top Page title can be changed. Enter the new title. •Refer to unavailable character set 1 on page 96 but [space] is available. •Refer to displayable character set on page 97. •Network Camera picture on Top Page can be changed. Enter the URL (http://) to display the picture on the specified web site. •Only [space] and [] are unavailable in the ASCII character table on page 96. •Network Camera picture on Top Page can be set the link to the specified web site. Enter the URL (http://). •Only [space] and [] are unavailable in the ASCII character table on page 96. Image Resolution•640 x 480 (cannot set on the Multi-Camera screen.) •320 x 240 (default) •160 x 120 Image Quality•Favor Clarity: Image is optimized for good clarity. •Standard: Image quality is standard. (default) •Favor Motion: Image is optimized for enhanced motion display. Refresh IntervalThe refresh interval of JPEG - Regularly Refresh can be selected. Select the desired interval. •10 seconds to 5 minutes Limit time of Continuous Motion JPEGTo make the network traffic smooth, select the duration time to display Motion JPEG. When the timer expires, the image changes to JPEG - Regularly Refresh. •10 seconds to Unlimited On the Air timeSpecifies the timetable to allow users to access Top View Image screen. When you access the image except the specified time, blue screen appears. •Always: Always allows users to access. •Operational between: Specifies the date and time to access the image.
Operating Instructions 66 3.5.7 Image Transfer Image Transfer window can set the Image Transfer feature. Network Camera can buffer images and send the images via e-mail or FTP. The request to send the image is initiated by a contact closure from the external sensors/devices connected to the External I/O using the Alarm mode. The external sensors/ devices are customer provided. The images can also be sent in the interval of time using the Timer mode. Make sure Date and Time has been configured. Refer to page 58 about Date and Time. Note When you use FTP or e-mail in transferring the image, you need to set Default Gateway and DNS Server address. Note The Alarm and Timer mode cannot be set at the same time. Non Transfer: Image Transfer feature is not in use. Alarm mode: The alarm trigger activates transferring the image. Refer to page 68. Timer mode: The timer trigger activates transferring the image. Refer to page 74.
Operating Instructions [For assistance, please call: 1-800-272-7033] 67 Non Transfer mode Non Transfer mode enables [Start Capture] on the operation bar to buffer the image on the Single Camera screen. Refer to page 46. Capture Control can lock [Start Capture] on the operation bar to prevent the user from capturing the Buffered Image. Click [Clear Buffered images] to clear the buffered image. [Clear Buffered images] does not save the parameters. 1.Click [Image Transfer] on Setup Page. 2.Select the each parameter. Click [Save] when finished. •Click [Cancel] to quit the current settings. The window returns to Setup Page without saving the parameters.
Operating Instructions 68 Transfer in the Alarm Mode The Alarm mode can transfer an image via e-mail or FTP when the alarm trigger is active. To activate the alarm trigger, the External Sensor Input of External I/O must be connected with the external sensors/devices. The Alarm mode can send the e-mail without transferring the image. The Alarm mode uses the Network Camera internal clock. Make sure Date and Time has been configured. Refer to page 58 about Date and Time. 1.Click [Alarm] on Image Transfer window. c. b. a. d. e. f.
Operating Instructions [For assistance, please call: 1-800-272-7033] 69 Instructions for the data fields a.External Sensor Input of External I/O activates the alarm trigger. Refer to page 94. b.Active Time of Trigger The active trigger time can be set in the primary time and the secondary time. The secondary time is the supplement of the primary time. Always: always activates the alarm trigger. Operational between: Sets the start and stop time of the primary time. The day of the week can be set by checking. Start and stop time is set only in 24 h time mode. Alarm enable condition: Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O. c.Secondary time is active trigger time except the primary time. Alarm enable condition: Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O. d.Sets the image resolution and image quality. Image resolution: 640 x 480/320 x 240/160 x 120 Image quality: Favor Clarity/Standard/Favor Motion e.The Pre or Post trigger or both can be set on the Buffered Image. Check the box. f.Image Frequency: Sets the interval to send the image. Maximum number of images per each trigger: Selects the number of buffering frames from numbers 1 to 400.
Operating Instructions 70 a.Selects Transfer Method. Non Transfer without Memory Over Write: Image buffering will stop when the internal memory is full. Non Transfer with Memory Over Write: Buffered image will overwrite the older image data when the internal memory is full. FTP: Enters the server address* 1 or Host Name*2, Port Number (1— 65535), Login ID*2 and password*2 to access the FTP server and upload file name*2 including full path. Time in 24 h mode is attached on the upload file name. Login timing: [Every Time] or [One Time] can be selected. When selecting [Every Time], Network Camera repeats logging in and out with each transfer of one image. When selecting [One Time], Network Camera stays logged in until the transfer of all images is completed. Select [One Time] when transferring many images in short duration time. a. b. c.