    [For assistance, please call: 1-800-272-7033]                                  61
    Instructions for the data fields
    Authentication 
    EnableAuthentication window can be set in the three patterns.
    None: No authentication window appears. Anyone can 
    access all screens (Single Camera/Multi-Camera screen) 
    and pages (Top Page and Setup Page).
    Administrator only: Authentication window appears when 
    accessing Setup Page. Authentication window does not 
    appear when accessing Top Page.
    Administrator and General User: Authentication window 
    appears when accessing Setup Page for the administrator 
    and Top Page for the general user.
    Administrator 
    Authentication 
    for Setup PageID: Enter the administrator ID.
    ID and Password are case sensitive.
    Password: 
    Enter the administrator password. The password should be 
    difficult to guess and confidential.
    Refer to unavailable character set 1 on page 96.
    Note
    Assign the ID and password to meet your specific 
    security requirements. To maximize its effectiveness, 
    keep the following contents.
    •Be sure the ID and password are different.
    •Make the ID and password as long and random 
    as possible.
    •Periodically change the password.
    Retype: 
    Reenter the password to confirm. Do not copy the text.
    Top pageAdministrator General User Unregistered User
    Setup page
    : Accessible— : Not accessible—
    —
    Top pageAdministrator General User Unregistered User
    Setup page
    : Accessible : Not accessible—
    —— — 
    						
    							Operating Instructions
    62
    3.5.5 Security: General User
    Security: General User window allows the administrator to create the general 
    user ID and password for the security level defined as general user. Up to 30 
    individual user names can be defined. The various security levels are explained 
    on page 61.
    1.Click [Security: General User] on Setup Page.
    2.Enter each parameter in the proper data field. Click [Save] when finished.
    •Click [Cancel] to leave the current settings unchanged. The window 
    returns to Setup Page without saving the parameters.
    •Restart to make Security: General User window settings effective to 
    all Motion JPEG viewers. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                  63
    Instructions for the data fields
    General User
    AuthenticationThe General User can be up to 30. Each of them can 
    have their own ID and password.
    (1) User ID List •User ID List displays the registered user name.
    •[Delete] and [Modify] deletes/modifies the general 
    user in the list. Select the desired user and click 
    [Delete] or [Modify].
    (2) New UserEnter the general user ID, password and reenter the 
    password to confirm. The password should be difficult 
    to guess and confidential. [Save] registers the new user 
    in the User ID List. ID and Password are case sensitive.
    Refer to unavailable character set 1 on page 96.
    Note
    Assign the ID and password to meet your specific 
    security requirements. To maximize its 
    effectiveness, keep the following contents.
    •Be sure the ID and password are different.
    •Make the ID and password as long and 
    random as possible.
    •Periodically change the password. 
    						
    							Operating Instructions
    64
    3.5.6 Top View Image
    Top View Image Setting window can change settings for Top Page, Single 
    Camera and Multi-Camera screen such as the initial language, the image 
    resolution, image quality, refresh interval as the initial setting, Limit time of 
    Continuous Motion JPEG and On the Air time.
    1.Click [Top View Image] on Setup Page.
    2.Select the each parameter. Click [Save] when finished.
    •Click [Cancel] to quit the current settings. The window returns to Setup 
    Page without saving the parameters.
    •Restart to make Limit Time of Continuous Motion JPEG settings 
    effective to all Motion JPEG viewers.
    Instructions for the data fields
    LanguageSelect the initial language from the list: English (US), English (UK), 
    French, German, Italian, Spanish or Japanese. The selected 
    language is displayed as the initial language on Top Page, Single 
    Camera screen and Multi-Camera screen. All Setup windows are 
    also changed when selecting English (US), English (UK) or 
    Japanese. English (UK) is displayed on Setup windows when 
    selecting French, German, Italian or Spanish. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                  65
    Instructions for the data fields
    Top Page•Top Page title can be changed. Enter the new title.
    •Refer to unavailable character set 1 on page 96 but [space] 
    is available.
    •Refer to displayable character set on page 97.
    •Network Camera picture on Top Page can be changed.
    Enter the URL (http://) to display the picture on the specified 
    web site.
    •Only [space] and [] are unavailable in the ASCII character 
    table on page 96.
    •Network Camera picture on Top Page can be set the link to the 
    specified web site. Enter the URL (http://).
    •Only [space] and [] are unavailable in the ASCII character 
    table on page 96.
    Image 
    Resolution•640 x 480 (cannot set on the Multi-Camera screen.)
    •320 x 240 (default)
    •160 x 120
    Image Quality•Favor Clarity: Image is optimized for good clarity.
    •Standard: Image quality is standard. (default)
    •Favor Motion: 
    Image is optimized for enhanced motion display.
    Refresh 
    IntervalThe refresh interval of JPEG - Regularly Refresh can be selected. 
    Select the desired interval.
    •10 seconds to 5 minutes
    Limit time of 
    Continuous 
    Motion JPEGTo make the network traffic smooth, select the duration time to 
    display Motion JPEG. When the timer expires, the image changes 
    to JPEG - Regularly Refresh.
    •10 seconds to Unlimited
    On the Air timeSpecifies the timetable to allow users to access Top View Image 
    screen. When you access the image except the specified time, blue 
    screen appears.
    •Always: Always allows users to access.
    •Operational between:
    Specifies the date and time to access the image. 
    						
    							Operating Instructions
    66
    3.5.7 Image Transfer
    Image Transfer window can set the Image Transfer feature. Network Camera can 
    buffer images and send the images via e-mail or FTP. The request to send the 
    image is initiated by a contact closure from the external sensors/devices 
    connected to the External I/O using the Alarm mode. The external sensors/
    devices are customer provided. The images can also be sent in the interval of time 
    using the Timer mode. Make sure Date and Time has been configured. Refer to 
    page 58 about Date and Time.
    Note
    When you use FTP or e-mail in transferring the image, you need to set Default 
    Gateway and DNS Server address. 
    Note
    The Alarm and Timer mode cannot be set at the same time. Non Transfer: Image Transfer feature is not in use.
    Alarm mode: The alarm trigger activates transferring the image. Refer to 
    page 68.
    Timer mode: The timer trigger activates transferring the image. Refer to page 
    74. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                  67
    Non Transfer mode
    Non Transfer mode enables [Start Capture] on the operation bar to buffer the 
    image on the Single Camera screen. Refer to page 46. Capture Control can lock 
    [Start Capture] on the operation bar to prevent the user from capturing the 
    Buffered Image. Click [Clear Buffered images] to clear the buffered image. 
    [Clear Buffered images] does not save the parameters. 
    1.Click [Image Transfer] on Setup Page.
    2.Select the each parameter. Click [Save] when finished.
    •Click [Cancel] to quit the current settings. The window returns to Setup 
    Page without saving the parameters. 
    						
    							Operating Instructions
    68
    Transfer in the Alarm Mode
    The Alarm mode can transfer an image via e-mail or FTP when the alarm trigger 
    is active. To activate the alarm trigger, the External Sensor Input of External I/O 
    must be connected with the external sensors/devices. The Alarm mode can send 
    the e-mail without transferring the image. The Alarm mode uses the Network 
    Camera internal clock. Make sure Date and Time has been configured. Refer to 
    page 58 about Date and Time.
    1.Click [Alarm] on Image Transfer window.
    c. b. a.
    d.
    e.
    f. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                  69
    Instructions for the data fields
    a.External Sensor Input of External I/O activates the alarm trigger. Refer 
    to page 94.
    b.Active Time of Trigger
    The active trigger time can be set in the primary time and the 
    secondary time. The secondary time is the supplement of the primary 
    time.
    Always: always activates the alarm trigger.
    Operational between: Sets the start and stop time of the primary time. 
    The day of the week can be set by checking. Start and stop time is set 
    only in 24 h time mode.
    Alarm enable condition:
    Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) 
    of External Sensor Input of the External I/O.
    c.Secondary time is active trigger time except the primary time.
    Alarm enable condition: 
    Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) 
    of External Sensor Input of the External I/O.
    d.Sets the image resolution and image quality. 
    Image resolution: 640 x 480/320 x 240/160 x 120
    Image quality: Favor Clarity/Standard/Favor Motion
    e.The Pre or Post trigger or both can be set on the Buffered Image. Check 
    the box.
    f.Image Frequency: Sets the interval to send the image. 
    Maximum number of images per each trigger: 
    Selects the number of buffering frames from numbers 1 to 400. 
    						
    							Operating Instructions
    70
    a.Selects Transfer Method.
    Non Transfer without Memory Over Write: 
    Image buffering will stop when the internal memory is full.
    Non Transfer with Memory Over Write: 
    Buffered image will overwrite the older image data when the internal 
    memory is full.
    FTP: Enters the server address*
    1 or Host Name*2, Port Number (1—
    65535), Login ID*2 and password*2 to access the FTP server and 
    upload file name*2 including full path. Time in 24 h mode is attached on 
    the upload file name.
    Login timing:
    [Every Time] or [One Time] can be selected. When selecting [Every 
    Time], Network Camera repeats logging in and out with each transfer 
    of one image. When selecting [One Time], Network Camera stays 
    logged in until the transfer of all images is completed. Select [One 
    Time] when transferring many images in short duration time.
    a.
    b.
    c. 
    						
    All Panasonic manuals Comments (0)