Home
>
Panasonic
>
Security Camera
>
Panasonic Network Camera BB-HCM381A BB-HCE481A Getting Started Manual
Panasonic Network Camera BB-HCM381A BB-HCE481A Getting Started Manual
Have a look at the manual Panasonic Network Camera BB-HCM381A BB-HCE481A Getting Started Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions 93 3.3 Creating, Modifying or Deleting General Users The General User page allows you to create, modify or delete general users. Up to 50 general users can be registered. The access level is set for each general user. If you set [Permit access from guest users] or [Permit access from guest users (mobile only)] on the Security: Administrator page, the access level can be set for guest users. Note For general users, the Setup and Maintenance tabs are not displayed. 1.Click [General Users] on the Setup page. 2.To create a general user, click [Create]. When setting [Do not permit access from guest users] When setting [Permit access from guest users] or [Permit access from guest users (mobile only)] To change the settings of general users or guest users, select their name and click [Modify]. The modification page is displayed. To delete a general user, select the name and click [Delete]. The confirmation page is displayed.
Operating Instructions 94 3.Set each parameter. Settings for general users Settings for guest users Clicking [Cancel] takes you back to the previous page without saving changes. Setting Description User ID List Up to 50 general users can be registered. The list is used to modify or delete general user settings. User Name/ Password User Name (6 to 15 characters): Enter the user name. Password (6 to 15 characters): Enter the password. Note The password must be different from the user name. Retype Password: Reenter the password. Enter ASCII characters (see page 190). Note that [Space], [], [], [&], [] and [:] are not available.
Operating Instructions 95 4.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 5.Click [Go to General User page]. The General User page is displayed.Setting Description Access Level An access level is set for each general user. Check each feature to enable access to it. In the limit time of continuous Motion JPEG setting, set the time for changing video (Motion JPEG) to still images for each user. (Not permitted, Unlimited, 10 seconds—60 minutes) In the refresh interval setting, set the refresh interval after the video has changed to still images. (3—60 seconds) See the corresponding page for details of the following features. Pan/Tilt Control (see page 25) Zoom Control (see page 26) Focus Control (see page 28) Preset Control (see page 23) Click to Center Control (see page 21) Brightness Control (see page 24) External Output Control (see page 24) Change Refresh Interval (see page 24) Change Resolution (see page 24) Change Quality (see page 24) Capture Image Button (see page 22) Listen (see page 34) Talk (see page 34) View Multi-Camera page (see page 36) View Buffered Image page (see page 38)
Operating Instructions 96 4 Buffering or Transferring Images 4.1 Procedures of Buffering or Transferring Images The procedures from this page to page 130 are described about settings of the image buffer or transfer. See the procedures below to understand the general outline of the settings. Buffer/Transfer by Timer (Page 97) Transfer Method (Select one from the lists.) No Transfer, No Memory Overwrite No Transfer, Memory Overwrite FTP E-mailTransfer Method (Select one from the lists.) No Transfer, No Memory Overwrite No Transfer, Memory Overwrite FTP E-mailTransfer Method (Select one from the lists.) No Transfer, No Memory Overwrite No Transfer, Memory Overwrite FTP E-mail Buffer/Transfer by Alarm Signal (Page 107) E-mail Notification When Triggered Setting Changing Motion Detection Sensitivity (Page 133) E-mail Notification When Triggered Setting Notifying the Alarm Log (Page 137)Notifying the Alarm Log (Page 137) Buffer/Transfer by Motion Detection Signal (Page 119) Time Setting Image Setting Image Buffer Frequency Setting Time Setting Image Setting Image Buffer Frequency Setting Save the settings to complete. Save the settings to complete. Time Setting Image Setting Lens Position When Triggered SettingLens Position When Triggered Setting Image Buffer Frequency Setting Save the settings to complete.
Operating Instructions 97 4.2 Buffering or Transferring Images by Timer The Trigger page allows you to enable image buffer/transfer by E-mail or FTP. Note If you are recording images to the SD memory card, refresh interval slows down. 1.Click [Trigger] on the Setup page. 2.Click a No. to enable buffer/transfer. 3.Check [Enable Image Buffer/Transfer], select [Timer] for the trigger, and click [Next>]. Click [Delete Buffered Images] to delete images already buffered. Click [Save] to save the settings. Clicking [Cancel] takes you back to the Trigger page without saving changes. Note If you click [Save], all buffered images on the SD memory card are deleted. Setting Description Enable Image Buffer/Transfer Check the box to enable the buffer/transfer. Uncheck the box to disable it.
Operating Instructions 98 4.Set the time, and click [Next>]. Note The timer works by an internal clock. Set the date and time before using timer buffer/transfer (see page 77). Clicking []. Clicking [
Operating Instructions 99 6.Set the image buffer frequency, and click [Next>]. Clicking [
Operating Instructions 100 7.Select the transfer method, and click [Next>]. Clicking [
Operating Instructions 101 When you set [FTP] for Transfer Method Select [FTP], and click [Next>]. The following page is displayed. Clicking [
Operating Instructions 102 Overwrite Setting Selecting [Overwrite File] overwrites the image on the server with a newer image. Selecting [Save as New File with Time Stamp] saves the image attaching time stamps on the file name, and the images are not overwritten. E.g. image20050101093020500 .jpg The underlined numbers mean 9h30min20s500ms on January 1, 2005. The letter s is inserted after the day when referring to a daylight saving time zone. Data Transfer Method Select [Passive Mode] normally. If the transfer does not work, select [Active Mode] and check the operation. *1 Note that [Space], [], [], [&], [] are not available. *2 Note that [] is not available. Setting Description