Page 41
41 To perform the settings of the encoder, display the top page of the encoder first. Refer to the network administrator about the required network addresses (IP addresses, etc.). 1. Enter the IP address of the encoder in the address box of the web browser and press the Enter key. For example, enter the default IP address of the encoder "192.168.0.10" in the address box of the web browser and press the Enter key. http://192.168.0.10/ The top page will be displayed. The top page of the encoder 2....
Page 42
42 ■CONTROL/STATE page (page 43) Destination IP address and destination port number of each of the VIDEO IN connectors streaming video and audio data to be sent Starting and stopping to encode video and audio data ■VIDEO page (for each video input channel) (page 44) Camera No. Camera title Destination IP address Destination port number Source port number Bit rate of streaming video and audio data TOS BIT TTL Starting up the encoder automatically Camera cable compensation Dynamic range Watermark GOP...
Page 43
43 CONTROL/STATE page ■Item Descriptions CH Number of the VIDEO IN 1 - 4 connectors DESTINATION IP ADDRESS/DESTINATION PORT No. Displaying the respective destination IP addresses and destination port numbers of each of the VIDEO IN connectors streaming video and audio data to be sent ENCODE STATE PLAY: Displayed during streaming transmission STOP:Displayed while stop streaming transmission CONTROL [START] button: Click this button to start encoding when the "ENCODE STATE" is "STOP"....
Page 44
44 VIDEO page Perform the settings for the VIDEO IN connectors respectively. The numbers of "CH" are the number of the VIDEO IN connectors respectively. Notes: •Click the [SET] button to save the changed settings. Otherwise, the changed settings will not be saved. •If 1.5 Mbps, 3.0 Mbps, or 3.8 Mbps is selected for "BIT RATE", the right edge of images may not be displayed. That is due to the characteristics of processing circuit. •When "BIT RATE" is changed, still images or blue...
Page 45
45 SOURCE PORT No. Enter a port number for the video and audio data source. 1024 to 65535 are available for the "SOURCE PORT No.". The default setting is 51000 for all channels. BIT RATE Enter a desired bit rate for streaming video and audio data. When a higher bit rate is selected, picture quality will be better. When a longer transmission delay is selected, the picture quality will be better. The actual time of transmission delay will differ depending on video and audio data. When "ON"...
Page 46
46 AUDIO page Note:Click the [SET] button to save the changed settings. Otherwise, the changed settings will not be saved. ■Item Descriptions To send audio from the audio source connected to the encoder, select "ON". To not to send audio from the audio source connected to the encoder, select "OFF". The default setting is "OFF" for all channels. camera and the decoder. When "STRONG" is selected, the authenticity of the watermark will be more reliable but the quality of...
Page 47
47 ALARM page Perform the settings for each alarm type and the alarm notification. Note:Click the [SET] button to save the changed settings. Otherwise, the changed settings will not be saved. ■Item Descriptions ALARM SETUP Perform the settings for each alarm type in detail. Click the button of the desired alarm type to go to the respective setting page. DRY CONTACT Setting of the action performed when the ALARM IN connector on the rear panel receives an alarm signal. CAMERA SITE ALARM Setting of the...
Page 48
48 ALARM-DRY CONTACT page Note:Click the [SET] button to save the changed settings. Otherwise, the changed settings will not be saved. ■Item Descriptions No. The numbers of the ALARM IN connectors MAKE CONTACT Set whether to control the encoder by making contact or not. When an alarm input continues for more than 100 ms, the encoder regards it as an alarm occurrence. OPEN When a closed contact is opened, the encoder regards it as an alarm occurrence. CLOSE When an open contact is closed, the encoder...
Page 49
49 RESET/TIMER (SEC) 1 - 60, 90, 120, 150, 180, 240, 300 - 3 600: 60 SEC INTERVAL When the alarm is reset, the bit rate returns to the set value on the VIDEO page and the alarm status is released. Select the method of release from the following. CGI RESET Resets the alarm using the CGI commands. Refer to "RESETTING THE ALARM/DISPLAYING THE ALARM STATUS" of the "HOW TO USE THE CGI COMMANDS" section on page 102. ALARM OFF TIMING Resets the alarm at the timing as follows: •Timing of a...
Page 50
50 ALARM-CAMERA SITE page Note:Click the [SET] button to save the changed settings. Otherwise, the changed settings will not be saved. ■Item Descriptions No. The numbers of the VIDEO IN connectors ON/OFF Set whether to control the encoder by alarm input or not. ON When the camera site alarm is detected, the following actions will be performed at the same time. •Notification of an alarm occurrence to the destination set on the ALARM page •Camera is controlled by a preset number •Changing of the bit rate...