Home > Panasonic > TV Receiver > Panasonic Mpeg2 Encoder Wj Gxe900 Operating Instructions

Panasonic Mpeg2 Encoder Wj Gxe900 Operating Instructions

Here you can view all the pages of manual Panasonic Mpeg2 Encoder Wj Gxe900 Operating Instructions. The Panasonic manuals for TV Receiver are available online for free. You can easily download all the documents as PDF.

Page 41

41
To perform the settings of the encoder, display the top
page of the encoder first.
Refer to the network administrator about the required
network addresses (IP addresses, etc.).
1. Enter the IP address of the encoder in the address
box of the web browser and press the Enter key.
For example, enter the default IP address of the
encoder "192.168.0.10" in the address box of the
web browser and press the Enter key.
http://192.168.0.10/
The top page will be displayed.
The top page of the encoder
2....

Page 42

42
■CONTROL/STATE page (page 43)
Destination IP address and destination port number
of each of the VIDEO IN connectors streaming video
and audio data to be sent 
Starting and stopping to encode video and audio
data
■VIDEO page (for each video input channel)
(page 44)
Camera No.
Camera title
Destination IP address
Destination port number
Source port number
Bit rate of streaming video and audio data
TOS BIT
TTL
Starting up the encoder automatically
Camera cable compensation
Dynamic range
Watermark
GOP...

Page 43

43
CONTROL/STATE page
■Item Descriptions
CH
Number of the  VIDEO IN 1 - 4 connectors
DESTINATION IP ADDRESS/DESTINATION PORT No.
Displaying the respective destination IP addresses
and destination port numbers of each of the VIDEO
IN connectors streaming video and audio data to be
sent
ENCODE STATE
PLAY:
Displayed during streaming transmission
STOP:Displayed while stop streaming transmission
CONTROL
[START] button:
Click this button to start encoding
when the "ENCODE STATE" is "STOP"....

Page 44

44
VIDEO page
Perform the settings for the VIDEO IN connectors
respectively. The numbers of "CH" are the number of the
VIDEO IN connectors respectively.
Notes:
•Click the [SET] button to save the changed settings.
Otherwise, the changed settings will not be saved.
•If 1.5 Mbps, 3.0 Mbps, or 3.8 Mbps is selected for
"BIT RATE", the right edge of images may not be
displayed. That is due to the characteristics of
processing circuit.
•When "BIT RATE" is changed, still images or blue...

Page 45

45
SOURCE PORT No.
Enter a port number for the video and audio data
source.
1024 to 65535 are available for the "SOURCE PORT
No.".
The default setting is 51000 for all channels.
BIT RATE
Enter a desired bit rate for streaming video and audio
data.
When a higher bit rate is selected, picture quality will
be better.
When a longer transmission delay is selected, the
picture quality will be better.
The actual time of transmission delay will differ
depending on video and audio data.
When "ON"...

Page 46

46
AUDIO page
Note:Click the [SET] button to save the changed
settings. Otherwise, the changed settings will not be
saved.
■Item Descriptions
To send audio from the audio source connected to the
encoder, select "ON".
To not to send audio from the audio source connected to
the encoder, select "OFF".
The default setting is "OFF" for all channels.
camera and the decoder.
When "STRONG" is selected, the authenticity of the
watermark will be more reliable but the quality of...

Page 47

47
ALARM page
Perform the settings for each alarm type and the alarm
notification.
Note:Click the [SET] button to save the changed
settings. Otherwise, the changed settings will not be
saved.
■Item Descriptions
ALARM SETUP
Perform the settings for each alarm type in detail.
Click the button of the desired alarm type to go to the
respective setting page.
DRY CONTACT
Setting of the action performed when the ALARM IN
connector on the rear panel receives an alarm signal.
CAMERA SITE ALARM
Setting of the...

Page 48

48
ALARM-DRY CONTACT page
Note:Click the [SET] button to save the changed
settings. Otherwise, the changed settings will not be
saved.
■Item Descriptions
No.
The numbers of the ALARM IN connectors
MAKE CONTACT
Set whether to control the encoder by making
contact or not.
When an alarm input continues for more than 100
ms, the encoder regards it as an alarm occurrence. 
OPEN
When a closed contact is opened, the encoder
regards it as an alarm occurrence. 
CLOSE
When an open contact is closed, the encoder...

Page 49

49
RESET/TIMER (SEC) 1 - 60, 90, 120, 150, 180, 240,
300 - 3 600: 60 SEC INTERVAL
When the alarm is reset, the bit rate returns to the
set value on the VIDEO page and the alarm status is
released. 
Select the method of release from the following.
CGI RESET
Resets the alarm using the CGI commands.
Refer to "RESETTING THE ALARM/DISPLAYING
THE ALARM STATUS" of the "HOW TO USE THE
CGI COMMANDS" section on page 102.
ALARM OFF TIMING
Resets the alarm at the timing as follows:
•Timing of a...

Page 50

50
ALARM-CAMERA SITE page
Note:Click the [SET] button to save the changed
settings. Otherwise, the changed settings will not be
saved.
■Item Descriptions
No.
The numbers of the VIDEO IN connectors
ON/OFF
Set whether to control the encoder by alarm input or
not.
ON
When the camera site alarm is detected, the
following actions will be performed at the same time.
•Notification of an alarm occurrence to the
destination set on the ALARM page
•Camera is controlled by a preset number
•Changing of the bit rate...