    Direct Preset Setup
    The following function requires the use of cameras
    equipped with the specific feature.
    This function enables registering of preset position number
    without opening the camera setup menu.
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Move the camera to the preset position to be regis-
    tered by moving the Joystick Controller and ZOOM,
    FOCUS Controls.
    3. Select the PrePOSI Setup (B5)Menu on the LCD dis-
    play by pressing the Direction buttons.
    4. Select the desired preset position number by pressing
    the Numeric keys, then press the Function (F1) button
    to register the position.
    Note:If the position number entered has been regis-
    tered previously, the old position will be overwritten
    by the new one.
    23
    456
    789
    MON CAM
    ESC SET0
    1
    PrePOSI SetUp
     Set B5
    F1 F2 F3 F4
    Patrol Learn and Play
    The following function requires the use of cameras
    equipped with the specific feature.
    A routine of manual operations can be stored for a specific
    time and later reproduced repetitively.
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Patrol Learn (B4)Menu on the LCD display
    by pressing the Direction buttons.
    3. Press the Function (F2)button to start Patrol Learn .
    “LEARNING” appears on the active monitor.
    4. Operate the camera manually. Operations data is
    stored.
    The stored data is as show below.
    Pan/Tilt, Lens Iris, Focus, Zoom and Preset Position
    5. Press the Function (F3)button to end the storage.
    To reproduce the stored data, follow the procedure shown
    below.
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Patrol Learn (B4)Menu on the LCD display
    by pressing the Direction buttons.
    3. Press the Function (F1)button to reproduce the stored
    Patrol function.
    4. Press the Function (F3)button to end the reproduction.
    PatrolLearn        
     Play Learn Stop
    F1 F2F3F4
    B4
    PatrolLearn        
     Play Learn Stop
    F1 F2F3F4
    B4
    55 
    						
    							107
    5
    Camera Power and Housing Control
    For remote camera power operation, a 24 V AC powered
    camera must be installed in the housing.
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Cam-Power Housing (B2) Menu on the LCD
    display by pressing the Direction buttons.
    3. Press the Function (F1) button to toggle the camera
    power on and off.
    4. Press the Function (F3) button to toggle the housing
    wiper on and off.
    5. Press the Function (F4)button to toggle the housing
    defroster on and off.
    Cam-Power Housing 
     Cam      Wiper Def
    F1F2F3F4
    B2
    F1 On:  Cam
      Off:  Cam
    F3 On:  Wiper
      Off:  Wiper
    F4On:  Def
    Off:  Def
    To prevent premature wearing of the wiper blades,
    be sure to turn off the wiper when it is not needed or
    before selecting another camera for viewing.
    Caution
     Running a Sequence
    Program Sequence
    The following functions are available only if a Program
    Sequence has been previously established through the Set
    Up Menu.
    As described on page 69, the Program Sequence can dis-
    play up to 128 cameras in a predetermined series on a
    selected monitor.
    1. Select the desired monitor.
    Refer to the Monitor Selection.
    2. Select 0 by pressing the Numeric key.
    3. Press the FORWARD SEQbutton to run the assigned
    Program Sequence in forward direction on the active
    monitor.
    123
    456
    789
    MON CAM
    ESC SET0
    A1
    Camera  01        
    Monitor 16  SLW 
     FST
    Camera  01        0
    Monitor 16  SLW 
     FST
    FORWARD
    SEQ
    P-Seq
    Monitor 16  
    						
    							8. Press the DEC –1CAM button to move the sequence
    one frame to the previous step (in forward or reverse
    run direction) from the step that was previously paused
    by pressing the STOP button
    9. Press the FORWARD SEQ button while the ALT indi-
    cator is on to restart the sequence forward from the
    beginning of the sequence step that was previously
    paused by pressing the STOP button.
    10. To return to Spot monitoring, select a camera.
    Refer to the Camera Selection.
    108
    4. Press the STOPbutton to pause the sequence that is
    being run on the active monitor.
    5. Press the FORWARD SEQbutton to restart the
    sequence forward from the step that was previously
    paused by pressing the STOP button.
    6. Press the BACK SEQ button to restart the  sequence
    backward from the step that was previously paused by
    pressing the STOP button.
    7. Press the INC +1CAMbutton to move the sequence
    one frame to the next step (in forward or reverse run
    direction) from the step that was previously paused by
    pressing the STOP button.
    STOP
    P-Seq      Stop
    Monitor 16 
    FORWARD
    SEQ
    P-Seq
    Monitor 16 
    BACK
    SEQ
    P-Seq
    Monitor 16 
    INC+1CAM
    P-Seq      Stop
    Monitor 16 
    SEQALTFORWARD
    DEC-1CAM
    P-Seq      Stop
    Monitor 16 
    55 
    						
    							109
    5
    Tour Sequence
    The following functions are available only if a Tour
    Sequence has been previously established through the Set
    Up Menu.
    As described on page 70, any one of 32 tours can be
    assigned to any one of 16 monitors.
    1. Select the desired monitor.
    Refer to the Monitor Selection.
    2. Select the desired Tour Sequence number by pressing
    the Numeric keys.
    3. Press the FORWARD SEQbutton to run the Tour
    Sequence in forward direction on the active monitor.
    4. Press the STOP button to pause a Tour Sequence that
    is being run on the active monitor.
    23
    456
    789
    MON CAM
    ESC SET0
    1
    A1
    Camera  01        
    Monitor 16  SLW  FST
    Camera  01        1
    Monitor 16  SLW  FST
    FORWARD
    SEQ
    T-Seq   01
    Monitor 16 
    STOP
    T-Seq   01 Stop
    Monitor 16 
    5. Press the FORWARD SEQbutton to restart a Tour
    Sequence forward from the step that was previously
    paused by pressing the STOP button.
    6. Press the BACK SEQbutton to restart a Tour
    Sequence backward from the step that was previously
    paused by pressing the STOP button.
    7. Press the INC +1CAM button to move the sequence
    one frame to the next step (in forward or reverse run
    direction) from the step that was previously paused by
    pressing the STOP button.
    8. Press the DEC –1CAM button to move the sequence
    one frame to the previous step (in forward or reverse
    run direction) from the step that was previously paused
    by pressing the STOP button.
    FORWARD
    SEQ
    T-Seq   01
    Monitor 16 
    BACK
    SEQ
    T-Seq   01
    Monitor 16 
    INC+1CAM
    T-Seq   01 Stop
    Monitor 16 
    DEC-1CAM
    T-Seq   01 Stop
    Monitor 16 
    						
    							110
    5
    9. Press the FORWARD SEQbutton while the ALTindi-
    cator is on to restart the sequence forward from the
    beginning of the sequence step that was previously
    paused by pressing the STOP button.
    10. To return to Spot monitoring, select a camera.
    Refer to the Camera Selection.
    SEQALTFORWARD
    Group Sequence
    The following functions are available only if a Group
    Sequence has been previously established through the Set
    Up Menu.
    As described on page 71, up to 8 Group Sequences can
    be set up.
    1. As described earlier, the Group Sequence determines
    which monitor is to be connected to which camera.
    Therefore, selecting a monitor is not required.
    2. Select G-seq(A2) Menu on the LCD display by press-
    ing the Direction buttons.
    3. Select the desired Group Sequence number by press-
    ing the Function buttons (F3/F4)or the Numeric keys.
    4. Press the Function (F1)button to run a Group
    Sequence forward on the assigned monitors.
                          
    G-Seq      <     > A2
    23
    456
    789
    MON CAM
    ESC SET0
    1
    F1F2F3F4
                          
    G-Seq      <     >
                     1   
    G-Seq      <     >
    F1F2F3F4
                     1   
    G-Seq      <     >
    G-Seq   01
    Monitor 16  
    						
    							111
    5
    5. Press the STOPbutton to pause a Group Sequence
    that is being run on the assigned monitor.
    6. Press the FORWARD SEQ button to restart a Group
    Sequence forward from the step that was previously
    paused by pressing the STOP button.
    7. Press the BACK SEQ button to restart a Group
    Sequence backward from the step that was previously
    paused by pressing the STOP button.
    8. Press the INC +1CAMbutton to move the sequence
    one frame to the next step (in forward or reverse run
    direction) from the step that was previously paused by
    pressing the STOP button.
    STOP
    G-Seq   01 Stop
    Monitor 16 
    FORWARD
    SEQ
    G-Seq   01
    Monitor 16 
    BACKSEQ
    G-Seq   01
    Monitor 16 
    INC+1CAM
    G-Seq   01 Stop
    Monitor 16 
    9. Press the DEC –1CAM button to move the sequence
    one frame to the previous step (in forward or reverse
    run direction) from the step that was previously paused
    by pressing the STOP button.
    10. Press the FORWARD SEQ button while the ALTindi-
    cator is on to restart the sequence forward from the
    beginning of the sequence step that was previously
    paused by pressing the STOP button.
    11. To return to Spot monitoring, select a camera.
    Refer to the Camera Selection.
    DEC-1CAM
    G-Seq   01 Stop
    Monitor 16 
    SEQALTFORWARD 
    						
    							112
    5
    Displaying Playback Video
    If the VCRs Video Output is connected to the Monitor Input
    (MONITOR IN) Connector on the WV-PB5504A Video
    Output Board, the VCRs video can be displayed on the
    monitor by the following procedures.
    When this function is selected, the Camera Title, Date, and
    Time are not displayed on the active monitor.
    1. Select the monitor connected to the Monitor Output
    (MONITOR OUT)Connector systemized with the con-
    nected VCRs Monitor Input (MONITOR IN)Connector.
    Refer to the Monitor Selection.
    2. Press the ALTbutton (indicator is on), then press the
    MON (ESC) key.
    The picture on the active monitor will be replaced by
    the video output connected to the Video Output Board.
    The display “in” appears on the LCD display as shown
    below.
    3. Press the ALT button again (indicator is off) to return to
    the original picture.
    23
    456
    789
    0
    1
    ALT
    A1
    MON CAM
    ESC SET
    Camera  01
    Monitor 01 [in]  SLW 
     FST
     Title Display
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Display (A3) Menu on the LCD display by
    pressing the Direction buttons.
    3. Press the Function (F1) button to toggle all items dis-
    played on the active monitor on and off.
    4. Press the Function (F2) button to toggle the monitor
    status display on the active monitor on and off.
    F1F3F4
    Display           
     All Mon Time Title
    MAY 0700 14:23:56
    C 01 M16 3rd Floor
    Pr64 Sp  Room  306
    F2
    A3
    F1
    MAY 0700 14:23:56
    C 01 M16 3rd Floor
    Pr64 Sp  Room  306
    F2
    MAY 0700 14:23:56
    C 01 M16 3rd Floor
    Pr64 Sp  Room  306 
    						
    							113
    5
    Camera Status Display
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Pan Action (B1)Menu on the LCD display by
    pressing the appropriate Direction buttons.
    3. Press the Function (F4)button to toggle the camera
    status display shown below on and off. 5. Press the Function (F3)button to toggle the date and
    time display on the active monitor on and off.
    6. Press the Function (F4) button to toggle the camera
    title display on the active monitor on and off.
    F3
    MAY 0700 14:23:56
    C 01 M16 3rd Floor
    Pr64 Sp  Room  306
    F4
    MAY 0700 14:23:56
    C 01 M16 3rd Floor
    Pr64 Sp  Room  306
    Site Status
    Ele Zoom:
    Shutter :
    Sens Up :
    Random  :
    Auto Pan:
    Camera  :
    Wiper   :
    Def     :
    AUX1    :
    AUX2    :
    C01  M16
    F1F2F3F4
    Pan Action
     Auto  Random Status
    B1 
    						
    							114
    5
    Camera Function Operation
    Electronic Shutter Mode
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Shutter(C1)Menu on the LCD display by
    pressing the appropriate Direction buttons.
    3. Select Shutter On mode by pressing the Function (F1)
    button.
    Pressing the Function (F3)button will select slower
    shutter speeds, or pressing the Function (F4) button
    will select faster shutter speeds.
    F3: 1/10 000 → 1/4 000 →1/2 000 →1/1 000 →1/500
    →1/250 →1/100
    F4: 1/100 →1/200 →1/400 →1/1 000 →1/2 000 
    →1/4 000 →1/10 000
    Note:The shutter speed varies by the selected cam-
    eras.
    4. Press the Function(F1)button to turn the electronic
    shutter mode off.
    Shutter Off        
     On
    C1
    F1F2F3F4
    Shutter Off
     On
    F1F2F3F4
    Shutter On
     Off        <   >
    F1F2F3F4
    Shutter Off
     On
    Shutter On
     Off        <   >
    Electronic Sensitivity Up Mode
    The following function requires the use of cameras
    equipped with the specific feature.
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Sens Up (C2) Menu on the LCD display by
    pressing the appropriate Direction buttons.
    3. Press the Function(F1)button to toggle the Auto
    Sensitivity Up Mode on and off.
    4. Press the Function (F2)button to toggle the Manual
    Sensitivity Up Mode on and off.
    5. In the On mode, pressing the Function(F3) button will
    select a lower sensitivity setting, or pressing the
    Function (F4) button will select a higher sensitivity set-
    ting in the selected mode.
    F3: X10 → X6 → X4 → X2 → X1
    F4: X1 → X2 → X4 → X6 → X10
    Note:The sensitivity varies by the selected cameras.
    6. Press the Function (F1)button (or Function (F2)button)
    to turn the Sensitivity Up Mode off.
    F1F2F3F4
    Sens Up Off
    Auto Manual C2
    F1F2F3F4
    Sens Up Off
    Auto Manual
    F1 F2F3F4
    Sens Up Auto
    Off  Manual <   >
    F1 F2F3F4
    Sens Up Off
    Auto Manual
    F1 F2F3F4
    Sens Up Manual
    Auto Off    <   > 
    						
    							115
    5
    Key No.
    Electronic Zoom Mode
    The following function requires the use of cameras
    equipped with the specific feature.
    a) Selecting Area after Zooming Procedures:
    1. Select the desired monitor and camera.
    Refer to the Monitor Selection and Camera Selection.
    2. Select the Ele Zoom (C3) Menu on the LCD display by
    pressing the appropriate Direction buttons.
    3. Select Ele Zoom On mode by pressing the Function
    (F1)button.
    A Zoomed picture appears on the active monitor with
    the area that was last selected.
    4. Press the Function (F3 orF4) button repeatedly to
    select the desired zoomed area.
    The zoomed area is switched over as shown in the fol-
    lowing table.
    F1F2F3F4
    Ele Zoom Off
     On  Posi C3
    F1F2F3F4
    Ele Zoom Off
     On  Posi
    F1F2F3F4
    Ele Zoom On
     Off Posi   <   >
    Selected Area
    →→→→
    →→→→ F3
    F4q w e r
    t
    qwert
    5. Press the Function (F1)button to turn the Electronic
    Zoom Mode off.
    F1 F2F3F4
    Ele Zoom On
     Off  Posi
    F1 F2F3F4
    Ele Zoom Off
     On   Posi  <   >
    w
    e
    rt q 
    						
    All Panasonic manuals Comments (0)