Page 321
Station Features and Operation (PT/SLT) User Manual321 4.3.51 Off-Hook Monitor While you are on a handset call, your call can be monitored by the other people in the room through SP-PHONE. Setting Switching from off-hook monitor to handset call Switching from off-hook monitor to hands-free mode DPT The SP-PHONE indicator light turns red. Your handset call is heard through the SP-PHONE. While on a handset call; SP-PHONE Press SP-PHONE. While in the off-hook monitor mode; SP-PHONE Press SP-PHONE. The...
Page 322
Station Features and Operation (PT/SLT) 322User Manual Conditions This feature is available for the following PT extensions only: KX-7431, KX-T7433, KX- T7436 If the SP-PHONE button is pressed during a handset call, either Off-Hook Monitor or SP- PHONE mode (hands-free mode) will be established. This is determined by System Programming . Making an OHCA call is not available if the other extension is in Off-Hook Monitor mode. Programming Guide References 2.8 System Option – Off-hook Monitor Features...
Page 323
Station Features and Operation (PT/SLT) User Manual323 4.3.52 One-Touch Dialing Allows you to make a call (intercom or outside) or access a system feature with the touch of a button. This is done by storing an extension number, telephone number or feature number (up to 24 digits) in a One-Touch Dialing button. Dialing Conditions One-Touch Dialing button can be programmed by Station, User or System Programming. If you store the telephone number of an outside party, a CO line access code (9, 801...
Page 324
Station Features and Operation (PT/SLT) 324User Manual Programming Guide References 4.3 Extension Line – CO Key – PF Key 4.4 DSS Console – DSS Key – PF Key Features Guide References 1.7 Dialing Features Full One-Touch Dialing One-Touch Dialing User Manual References 2.2.3 Flexible Button Assignment 2.2.4 Full One-Touch Dialing Assignment 3.2.5 [005] Flexible CO Button Assignment 5.2.13 One-Touch Dialing Button (Assignment) 5.2.14 One-Touch Access Assignment for System Features 5.2.23 One-Touch...
Page 325
Station Features and Operation (PT/SLT) User Manual325 4.3.53 Operator Call Allows you to call an operator within the system. Conditions If no operator is assigned, this feature is not available and you will hear a reorder tone after dialing the feature number. Operator FDN The treatment of incoming calls to Operator is decided according to Operator FDN setting of the tenant . — If the FDN for Operator Group is set as the destination of Extension Group or Incoming Group, calls by the feature number...
Page 326
Station Features and Operation (PT/SLT) 326User Manual 2.3 Numbering Plan – Operator Call 3.3 Extension Group – FDN – Group Type – Tenant No. – [Overflow Setting] Destination – Day / Night – [Overflow Setting] Timer – [Operator Setting] Ringing Type – [Operator Setting] Call Priority 3.5 Incoming Group – FDN – Group Type – [Overflow Setting] Destination - Day / Night – [Overflow Setting] Timer – [Operator Setting] Ringing Type – [Operator Setting] Call Priority 4.2 Trunk Line – Trunk Line –...
Page 327
Station Features and Operation (PT/SLT) User Manual327 4.3.54 Outward Dialing, Trunk Access There are the following your ways to select an idle CO line for making a call. Trunk Access – Idle Type Description How to access IdleSelects an idle CO line automatically from the trunk groups assigned to the extension.Dial the feature number for Local CO Line Access / ARS (default=9). Or press a Loop-CO (L-CO) Button. DirectSelects an idle CO line by pressing an idle CO button directory.Press an idle CO...
Page 328
Station Features and Operation (PT/SLT) 328User Manual Trunk Access – Direct Trunk Access – Individual Trunk PT Press CO.Dial the phone number. phone no. Lift the handset or press SP-PHONE/MONITOR.Hang up or press SP-PHONE/MONITOR. Dial toneTalk. (CO) The CO indicator light turns green.The display shows the phone number. You may press a CO button (S-CO, G-CO or L-CO) button directly without first going off-hook. PT Press CO assigned as Single-CO.Dial the phone number. phone no. Lift the handset or...
Page 329
Station Features and Operation (PT/SLT) User Manual329 Trunk Access – Trunk Group Conditions [General] Class of Service (COS) programming COS programming determines the trunk group available for each extension user . All PTs in the system have one L-CO button by default. Flexible CO Button Assignment A flexible CO button can be assigned as an S-CO, G-CO or L-CO button by Station, User or System Programming as follows: Button Type Assignable parameters Single-CO (S-CO)A specific outside line is...
Page 330
Station Features and Operation (PT/SLT) 330User Manual After dialing the feature number or pressing the CO button, you will hear one of the following tones: Dial tone: Indicates an idle CO line is seized. —is shown on the display, if available. (xxxxx: trunk port physical number) Busy tone: Indicates the selected CO line is busy. —is shown on the display, if available. Reorder tone: 1) Indicates the CO line you have attempted to access is not assigned. —is shown on the display, if available. 2)...