Panasonic Kx-Td500 Features Guide
Here you can view all the pages of manual Panasonic Kx-Td500 Features Guide. The Panasonic manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 31
BFeatures Guide 22 Features Guide Busy Station Signaling (BSS) DescriptionUsed to prompt a busy extension (engaged in a call) to answer a new incoming call. When BSS is activated by the calling exten- sion, a call waiting tone is generated at the busy extension to inform that another call is waiting. Conditions ¥ BSS feature functions, if the other busy extension is an ICM type PT in the following state: (1) The extension is off-hooked. (2) ICM button is idle. (3) ÒCall WaitingÓ is enabled. ¥ BSS...
Page 32
Features GuideB Features Guide 23 Button, Direct Station Selection (DSS) DescriptionDSS button permits the PT user One-Touch access to other exten- sion users. Conditions¥ A DSS button can be assigned to a flexible CO button on a PT by Station, User or System Programming. ¥ Busy Lamp Field Once a button is assigned as a DSS button, it provides Busy Lamp Field (BLF) status. Programming References System Programming................................Installation Manual, Section 4 4.4.2 Line - Extension...
Page 33
B Features Guide 24 Features Guide Button, Flexible DescriptionThe use of Flexible Buttons on PT is determined by Station, User or System Programming. The following three types of Flexible Buttons are provided on PT and/or DSS Consoles: ¥ Flexible CO buttons(provided on all PTs) ¥ Flexible DSS buttons(provided on DSS Consoles) ¥ Flexible PF (Programmable Feature) buttons Assignable featur es by Flexible Button type Ò4Ó indicates that the feature is available. * Available for monitoring the call...
Page 34
Features GuideB Features Guide 25 Conditions¥Station Programming mode A PT in Station Programming mode is treated as a busy extension. CO buttons and DSS buttons on a PT in Station Programming mode do not show the indication of call activity. ¥Flexible CO buttons Flexible CO buttons are provided on all types of PTs. Programming References System Programming................................Installation Manual, Section 4 4.4.2 Line - Extension Line Ñ Flexible CO Key Assignment Ñ Flexible PF Key Assignment...
Page 35
BFeatures Guide 26 Features Guide BUTTON, LINE ACCESS Ñ SUMMARY DescriptionUsed to get a line for making/answering a call. Line Access Buttons are provided on PTs only. They are categorized as follows: All PTs in the system can be categorized as or . (default) ICM button + CO buttons All PTs in the system have one ICM button and one L-CO button by default. DN button(s) + CO buttons If at least one PDN is assigned, all intercom calls come on a PDN button instead of ICM button. Conditions¥ DN buttons...
Page 36
Features GuideB Features Guide 27 Button, Line Access Ñ Group-CO (G-CO) DescriptionTo support efficient utilization of CO lines, a group of CO lines (Trunk Group) can be assigned to a flexible CO button as Group- CO (G-CO). Any incoming call from CO lines in the Trunk Group arrives at the G-CO button. To make an outside call, the extension user can get an idle CO line in the trunk group simply by pressing the assigned G-CO button. Assignable for both ICM type and DN type PTs. LED Indicator Patterns...
Page 37
BFeatures Guide 28 Features Guide Programming References System Programming................................Installation Manual, Section 4 4.2.3 System - Class of Service Ñ Trunk Group Setting 4.3.1 Group - Trunk Group 4.4.2 Line - Extension Line Ñ Flexible CO Key Assignment 4.4.3 Line - DSS Console Ñ Flexible DSS Key Assignment User Programming...............................................User Manual, Section 3 [005] Flexible CO Button Assignment Station...
Page 38
Features GuideB Features Guide 29 Button, Line Access Ñ INTERCOM (ICM) DescriptionUsed to make or receive intercom calls, and to set or cancel vari- ous features. Available for an ICM type PT only. ConditionsNone Programming References None Feature ReferencesInter Office Calling LED Indication Operation ReferencesBasic Operations................................................User Manual, Section 4.2 Making Calls Receiving Calls Indicator Off Green On Green slow flash Green moderate...
Page 39
BFeatures Guide 30 Features Guide Button, Line Access Ñ Loop-CO (L-CO) DescriptionAll CO lines in the system or in a tenant (if ÒTenant ServiceÓ is utilized) can be assigned to a flexible CO button on a PT as a Loop-CO (L-CO) button. An incoming CO call on any CO line arrives at the L-CO, unless there are S-CO or G-CO buttons asso- ciated with the line or unless the L-CO button is already in use. The PT user can get an idle CO line simply by pressing the dedi- cated L-CO button. Available for both ICM...
Page 40
Features GuideB Features Guide 31 ¥Ringing Tone Selection (DPT only) A ringing tone type for L-CO buttons can be selected either by Station or System Programming. Programming References System Programming................................Installation Manual, Section 4 4.2.3 System - Class of Service Ñ Trunk Group Setting 4.2.5 System - Local Hunt Sequence 4.4.2 Line - Extension Line Ñ Flexible CO Key Assignment User Programming...............................................User Manual, Section 3...