Have a look at the manual Panasonic Hd Integrated Camera Aw He60h Vol1 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
21 Installation Instructions Connection\f(continued) pwSy\ftem examp\be 1 (Seria\b con\gtro\b) YPBPRVINOUT Acce\f\fory AC adaptor HD Integrated Camer\ga AW - HE60S HD Integrated Camer\ga* AW - HE60S SDI video \figna\b SwitcherMonitor 1 Monitor 2 Monitor Monitor Pan-ti\bt head and ca\gmera contro\b \figna\b (LAN cab\be (\ftraight cab\be) Sy\ftem TALLY AC Adapter AW - PS550 Mu\bti-Function Cont\gro\b\ber AW - RP655 Gen\bock \figna\b generator *: The A C adaptor provided with the uni\gt i\f not \fhown in the above figure. RJ-45 re\bay adapter Mu\bti-Interface Cab\g\be AW - CA20T6 pSDI output is supp\gor ted only by the AW- HE60S. p The multi-interface cable (AW - \fA20T6) is needed in\g order for the control sign\gals to be connecte\gd. p Use a str aight cable for the LAN cable.
22 Connection\f(continued) pwSy\ftem examp\be 2 (IP contro\b) Acce\f\fory AC adaptor Acce\f\fory AC adaptor Acce\f\fory AC adaptor HD Integrated Camer\ga AW - HE60S HD Integrated Camer\ga* AW - HE60S Gen\bock \figna\b generator SDI video \figna\b Switching hub LAN cab\be (\ftraight cab\be) Compact Live Switcher AW - HS50 Monitor 1 Monitor 2 Monitor Monitor LAN cab\be (\ftraight cab\be) Remote Camera Contr\go\b\ber AW - RP50 *: The A C adaptor provided with the uni\gt i\f not \fhown in the above figure. Per\fona\b computerIP video di\fp\bay IP video di\fp\bay Wire\be\f\f acce\f\f point Mobi\be termina\b pSDI output is supp\gor ted only by the AW- HE60S. p Use a str aight cable for the LAN cable.
23 Installation Instructions Appearance Unit: mm (inch) R80 (R3-5/32) 160 (6-5/16) 85 (3-11/32) 80 (3-5/32) 72 (2-13/16) 166 (6-9/16)3 (1/8) 55 (2-3/16) 123 (4-13/16)175 (6-7/8) AW- HE60H AW - HE60S
24 indicates safety information. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN \fAUTION: TO REDU\fE THE RISK OF ELE\fTRI\f \gSHO\fK, DO NOT RE\bOVE \fOVER (OR BA\fK). NO USER SERVI\fEABLE PARTS INSIDE. REFER TO SERVI\fING TO QUALIFIED SERVI\fE PERSONNEL. The lightning flash\g with arrowhead symbol, within an equilate\gral triangle, is intended to alert the user to the \gpresence of uninsu\glated “dangerous voltage” within the product\g’s enclosure that may be of sufficient\g magnitude to constitute a risk of electric shock to persons. The exclamation point w\githin an equilater\gal triangle is intended t\go alert the user to the presence of im\gportant operating and maintenance (servicing) instructions in the literature accompanying the appliance. Read thi\f fir\ft! (For AW- HE60HN, AW- HE60SN) WARNING: This equipment must be grounded. To ensure safe operation, the three-p\gin plug must be inserted only into a sta\gndard three-pin power outlet which is ef\gfectively grounded through normal household wiring. Extension cords use\gd with the equipmen\gt must have three cores and b\ge correctly wired t\go provide connection to the \gground. Wrongly wired extension cords are a major c\gause of fatalities. The fact that the equip\gment operates satisfactorily does not imply that\g the power outlet is grounded or that the installat\gion is completely \gsafe. For your safety, if you are in any doubt about the e\gffective grounding of the power outlet, please \gconsult a qualifie\gd electrician. WARNING: • To reduce the risk of fire or ele\gctric shock, do not expose this equipme\gnt to rain or moisture. • T o reduce the risk of fire or ele\gctric shock, keep this equipment away from all liquids. Use and store only\g in locations which\g are not exposed to the risk of dripping or splashing\g liquids, and do not place a\gny liquid containers o\gn top of the equip\gment. CAUTION: To reduce the risk of fire or ele\gctric shock and annoying interference, use the recommen\gded accessories only. CAUTION: In order to maintai\gn adequate ventilation, do not \g install or place t\ghis unit in a book\gcase, built-in cabinet or any other confined sp\gace. To prevent risk of electric shock or fire hazard due\g to overheating, ensure t\ghat curtains and any other materials do not obstruct the ventilation. CAUTION: The mains plug of t\ghe power supply cord shal\gl remain readily operable. The A\f receptacle (mains\g socket outlet) shall b\ge installed near the \gequipment and shall\g be easily accessible. To completely discon\gnect this equipmen\gt from the A\f mains, disconnect the po\gwer cord plug from the A\f receptacle. CAUTION: This apparatus can be operated at a voltage in the range of 100 – 240 V A\f. Voltages other than \g120 V are not intended f\gor U.S.A. and \fanada. Operation at a voltage other than 1\g20 V A\f may require the use of\g a different A\f plug. Please contact either a local or \gforeign Panasonic authorized service center for assistance in s\gelecting an alternate A\f plug. CAUTION: \fheck the installation\g at least once a y\gear. An improper instal\glation could cause \gthe unit to fall off resulting in person\gal injury. CAUTION: Do not pick up and move the unit while t\ghe tripod is attached. The fitting may break under the w\geight of the tripod, which may result in injury.
25 Operating Instructions indicates safety information. This device complies with\g part 15 of the F\f\f Rule\gs. Operation is subject t\go the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired op\geration. FCC Note: This equipment has\g been tested and found to comply with\g the limits for a class A digital\g device, pursuant to Part 15 of the F\f\f Rules. These limits are de\gsigned to provide reasonable protection again\gst harmful interference when the equipment is operated in a commercia\gl environment. This equipment gene\grates, uses, and can radiate radio frequency energy, and if not instal\gled and used in accor\gdance with the inst\gruction manual, may cause harmful interference to radio communications. Operation of this equi\gpment in a resident\gial area is likely to cause harmful interference in which case the user will\g be required to cor\grect the interference at his own expense. Warning: To assure continued F\f\f emission lim\git compliance, the user must use only shiel\gded interface cables when connectin\gg to external units. If DVI-D port is to be used it \gmust be connected to\g P\f by compatible interface cable with two ferrite cores. Also, any unauthorized changes or modifi\gcations to this eq\guipment could void the user’s authority to operate it. Read thi\f fir\ft! (For AW-HE60HN, AW- HE60SN)(continued) NOTIFICATION (Canada) IMPORTANT SAFETY INSTRUCTIONS 1) Read these instr uctions. 2) K eep these instructions. 3) Heed all w arnings. 4) F ollow all instructions. 5) Do not use this ap\gpar atus near water. 6) \flean only with dr y cloth. 7) Do not b lock any ventilation openings\g. Install in accorda\gnce with the manufacturer’s instructions. 8) Do not install nea\gr an y heat sources suc\gh as radiators, heat registers, stoves, or other apparatus (including ampl\gifiers) that produce heat. 9) Do not def eat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider\g than the other. A grounding-type plug h\gas two blades and a third grounding prong. The wide blade or the third pr\gong are provided for your safety. If the provided plug does not f\git into your outlet, consul\gt an electrician for replacement of \gthe obsolete outlet. 10) Protect the po wer cord form being walked on or pinched particularly at plugs, convenience receptacles, and the point whe\gre they exit from the appar\gatus. 11) Only use attachment\gs/accessor ies specified by the manufacturer. 12) Use only with the \gcar t, stand, tripod, bracket, or table specified by the manufacturer, or sold with the \gapparatus. When a cart is used, use caut\gion when moving the cart/apparatus combination t\go avoid injury from tip-over. 13) Unplug this appar atus during lightning storms or when unused for long periods of time. 14) Ref er all servicing to qualified \gservice personnel. Servicing is required w\ghen the apparatus has been damage\gd in any way, such as power-supply cord or p\glug is damaged, liqui\gd has been spilled o\gr objects have fallen into the app\garatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropp\ged. FCC NOTICE (USA) Thi\f c\ba\f\f A digita\b appara\gtu\f comp\bie\f with Can\gadian ICES-003.
26 indicates safety information. WARNING: This equipment must be earthed. To ensure safe operation, the three-p\gin plug must be inserted only into a sta\gndard three-pin power point which is eff\gectively earthed through the nor\gmal household wiring. Extension cords use\gd with the equipmen\gt must have three cores and b\ge correctly wired t\go provide connection to the \gearth. Wrongly wired extension cords are a major c\gause of fatalities. The fact that the equip\gment operates satisfactorily does not imply that\g the power point is earthed or that the installation i\gs completely safe. For your safety, if you are in any doubt about the e\gffective earthing of the power point, please c\gonsult a qualified \gelectrician. WARNING: • To reduce the risk of fire or ele\gctric shock, do not expose this equipme\gnt to rain or moisture. • T o reduce the risk of fire or ele\gctric shock, keep this equipment away from all liquids. Use and store only\g in locations which\g are not exposed to the risk of dripping or splashing\g liquids, and do not place a\gny liquid containers o\gn top of the equip\gment. CAUTION: To reduce the risk of fire or ele\gctric shock and annoying interference, use the recommen\gded accessories only. CAUTION: In order to maintai\gn adequate ventilation, do not \g install or place t\ghis unit in a book\gcase, built-in cabinet or any other confined sp\gace. To prevent risk of electric shock or fire hazard due\g to overheating, ensure t\ghat curtains and any other materials do not obstruct the ventilation. CAUTION: The mains plug of t\ghe power supply cord shal\gl remain readily operable. The A\f receptacle (mains\g socket outlet) shall b\ge installed near the \gequipment and shall\g be easily accessible. To completely discon\gnect this equipmen\gt from the A\f mains, disconnect the po\gwer cord plug from the A\f receptacle. CAUTION: \fheck the installation\g at least once a y\gear. An improper instal\glation could cause \gthe unit to fall off resulting in person\gal injury. CAUTION: Do not pick up and move the unit while t\ghe tripod is attached. The fitting may break under the w\geight of the tripod, which may result in injury. Read thi\f fir\ft! (For AW- HE60HE, AW- HE60SE) EEE Yönetmeliğine Uygundur. EEE Complies with Directive of Turkey. CAUTION: Do not remove panel covers by unscrewing. To reduce the risk of electric shock, do not remove the covers. No user serviceable parts inside. Refer servicing to qualified \gservice personnel.
27 Operating Instructions EMC NOTICE FOR THE PURCHASER/USER\g OF THE APPARATUS 1. App\bicab\be \ftandard\f and operating en\gvironment The apparatu\f i\f com\gp\biant with: • standards EN55103-\g1 and EN55103-2 200\g9, and • electromagnetic e\gn vironment E4. In a residential, c\gommercial, light in\gdustr ial and urban outdoo\grs environment, this pr\goduct may cause radio interference. 2. Pre-requi\fite condi\gtion\f to ac hieving comp\biance with \gthe above \ftandard\f P eriphera\b equipment\g to be connected to\g the apparatu\f and \g\fpecia\b connecting cab\g\be\f • The purchaser/user\g is urged to use onl\gy equipment which \ghas been recommende\gd b y us as peripheral equipment to be connected to \gthe apparatus. • The purchaser/user\g is urged to use onl\gy the connecting ca\gb les described below. For the connecting c\gab \be\f, u\fe \fhie\bded cab\be\f which \fuit the intended\g purpo\fe of the app\garatu\f. • Video signal connect\ging cab les Use double shielded coaxial \gcables, which are designed\g for 75-ohm type high\g-frequency applica\gtions, for SDI (Serial Digital Interface). \foaxial cables, which are designed\g for 75-ohm type high\g-frequency applica\gtions, are recommended for analog video signals. • A udio signal connecti\gng cables If your apparatus supports AES/EBU serial digital audio si\ggnals, use cables designed for AES/EBU. Use shielded cables, which provide quality performance for high-frequency t\gransmission applica\gtions, for analog audio signals. • Other connecting ca\gb les Use double shielded cables, which provide quality performance for high-frequency a\gpplications, as connecting cables for IEEE1394 and USB\g. • When connecting to \gthe HD\bI signal ter\g minal, use multilayer shielded cables, which provide quality performance for high-frequency appl\gications. • When connecting to \gthe D VI signal terminal, use a cable with a ferrite core. • If y our apparatus is supplied wi\gth ferrite core(s), they must be attached on \gcable(s) following instructions in this manual. 3. P erformance \beve\b The perf ormance level of the apparatus is equivalent to or better\g than the performance level required by these standards. However, the apparatus may be adversely affected by interference if it is be\ging used in an E\b\f en\gvironment, such as\g an area where strong e\glectromagnetic fiel\gds are generated (by the presence of \gsignal transmission towers, cellular phones, etc.). In order to minimi\gze the adverse effects of the interf\gerence on the appa\gratus in cases like this, it is recommended \g that the following steps be taken with the apparatus being affected and with its o\gperating environment: 1. Place the apparatus at a distance \gfrom the source of\g the interference. 2. \fhange the directi\gon of the apparatus. 3. \fhange the connec\gtion method used for the apparatus. 4. \fonnect the appar\gatus to another po\gwer outlet where th\ge power is not shared by any other appliances\g. Read thi\f fir\ft! (For AW- HE60HE, AW- HE60SE)(continued)
28 FOR U.K. ONLY This appliance is \gsupplied with a mou\glded three pin mains plug for your safety and convenience. A 13 amp fuse is f\gitted in this plug. Should the fuse nee\gd to be replaced ple\gase ensure that the replacement fu\gse has a rating of 13 amps an\gd that it is approved by ASTA or BSI to BS1362\g. \fheck for the ASTA mark or the BSI mark on the body of the fuse. If the plug contain\gs a removable fuse cover you must ensure that it is \grefitted when the f\guse is replaced. If you lose the fuse c\gover the plug must not be used until a replacemen\gt cover is obtained. A replacement fuse\g cover can be purchase\gd from your local Panasonic Dealer. \faution for A\f \bains Lead FOR YOUR SAFETY PLEASE \gREAD THE FOLLOWING TEXT CAREFULLY. Thi\f product i\f equipped w\gith 2 type\f of AC main\f cab\be. One i\f for continenta\b Europe, etc. and the other one\g i\f on\by for U.K. Appropriate mains cable must be used in each\g local area, since\g the other type of\g mains cable is not suitable.FOR CONTINENTAL EUROPE, ETC. Not to be used in t\ghe U.K. FOR U.K. ONLY If the plug supplie\gd is not suitable for your socket outlet, it should b\ge cut off and appro\gpriate one fitted. How to rep\bace the fu\g\fe 1. Open the fuse compa\gr tment with a screwdriver. 2. Replace the fuse . Fuse indicates safety information. Pursuant to at the directive 2004/108/EC, article 9(2) Panasonic Testing Centre Panasonic Service Europe, a division of Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, F.R. Germany Read thi\f fir\ft! (For AW- HE60HE, AW- HE60SE)(continued)
29 Operating Instructions Before u\fe pwOverview pThis unit is a com\gpact full HD camer\g a integrated with a pan-tilt head and featuring a 1/3-type full\g HD \bOS sensor and digital signal pr\gocessor (DSP). p In addition to its o\gptical 18 zoom lens, the unit comes with a 10 digital zoom to achieve high-quality shoo\gting that overflows with ambiance. p The unit features a night mode, making it possible to shoot even under very-low-brightness conditions \gby exposing subjects to infrared rays. p T wo models are available: the HD\bI model AW - HE60H which is ideal for distributing the signals o\gf TV conference and other video events, and the SDI outpu\gt model AW - HE60S which is idea\gl for creating content\g. IP video transfer and IP control c\gan be performed for both models. It is also possible to connect to a\gn existing camera controller using se\grial control. pw Required per \fona\b computer environment CPU Intel® \foreT\b2 DUO 2.4 GHz or faster or \fPU with the equiv alent specificatio\gns Memory [When u\fing Window\f] 512 \bB or more (When using \bicroso\gft ® Windows® 7: 1 GB [32 bits] or 2 GB [64 bits] or more) [When u\fing Mac OS X\g] 2 GB or more Network function 10Base-T or 100Bas\ge-TX port 1 Image di\fp\bay function Resolution: 1024 768 pixels or more \folor generation: T rue \folor 24 bits or\g more Supported operating \fy\ftem and Web brow\fer \bicrosoft ® Windows® 7 Professional SP1 64-bit*1 \bicrosoft® Windows® 7 Professional SP1 32-bit*1 Windows® Internet Explorer® 8.0*2 Windows® Internet Explorer® 9.0*2 \bicrosoft® Windows® XP Home Edition SP3*3 \bicrosoft® Windows® XP Professional Edition SP3*3 Apple \bac OS X v10.5 Saf ari 5.0.6 Apple \bac OS X v10.6 Saf ari 5.1.5 Apple \bac OS X v10.7 Saf ari 5.1.5 *1: This cannot be use\gd in the Windows® XP compatibility \gmode. *2: This cannot be use\gd with the 64-bit v ersion of Internet Explorer ® 8.0. *3: The \bicrosoft® Windows® XP Professional x64 Editio\gn is not supported. Other \fD-RO\b drive (for using the Operating Instructions and various software) DirectX ® 9.0c and up Adobe ® Reader® (for browsing the Operating Instructions on the \fD-RO\b)
30 Before u\fe(continued) IMPORTANT pFai\bure to provide the required \gper\fona\b computer environment may \f\bow down the de\bineation \gof the image\f on the \fcreen, make it impo\f\fib\be for the web brow\fer to work and cau\fe other\g kind\f of prob\bem\f. pWhen using \bicrosof\gt® Windows® 7, refer to the “Notes on Windo ws® 7” (page 105 in the ) f or details on the p\gersonal computer environment that is \grequired and on the \gprecautions and other items. pw Di\fc\baimer of warranty IN NO EVENT SHALL P\ganasonic \forporation BE LIABLE TO ANY PARTY OR ANY PERSON, EX\g\fEPT FOR REPLA\fE\bENT OR REASONABLE \g\bAINTENAN\fE OF THE PRODU\fT, FOR THE \fASES, IN\fLUDING BUT NOT LI\bITED TO BELOW: 1 ANY D A\bAGE AND LOSS, IN\fLUDING WITHOUT LI\bITATION, DIRE\fT OR INDIR\gE\fT, SPE\fIAL, \fONSEQUENTIAL OR EXE\bPLARY, ARISING OUT OF OR RELATING TO THE PRODU\fT; 2 PERSONAL INJUR Y OR ANY DA\bAGE \fAUSED BY INAPPROPRIATE USE OR NEGLIGENT\g OPERATION OF THE USER; 3 UNA UTHORIZED DISASSE\bBL\gE, REPAIR OR \bODIFI\fATION OF THE PRODU\fT BY THE USER; 4 IN\fONVENIEN\fE OR ANY \gLOSS ARISING WHEN I\bAGES ARE NOT DISPLAYED, DUE TO ANY REASON OR \fAUSE IN\fLUDING ANY F\gAILURE OR PROBLE\b OF THE PRODU\fT; 5 ANY PR OBLE\b, \fONSEQUENTIAL IN\fONVENIEN\fE, OR LOS\gS OR DA\bAGE, ARISING OUT OF THE SYSTE\b \fO\bBINED BY THE DEVI\fES OF THIRD PARTY; 6 ANY DE\bANDS FOR \fO\bPE\gNSA TION, \fLAI\bS, ET\f. O\f\fASIONED BY THE INFRINGE\bENT OF \g PRIVA\fY BY INDIVIDUALS OR ORGANIZATIONS WHOSE I\bAGES WERE SHOT BY THE USER BE\fAUSE THESE I\bAGES (IN\fLUDING THE RE\fORDINGS \bADE) WERE \bADE AVAILABLE BY THE USER BE\fAUSE IN THE PUBLI\f DO\bAIN FOR SO\bE REASON OR OTHER OR BE\fAUSE THE I\bAGES ENDED UP BEING\g USED FOR PURPOSES OTHER THAN THE ONE DES\fRIBED AB\gOVE; 7 LOSS OF REGISTERED D\g ATA \fAUSED BY ANY FAILURE. pw Network \fecurity As you will use this u\gnit connected to a \gnetwork, your attention is calle\gd to the following security risks. 1 Leakage or theft of\g inf ormation through this\g unit 2 Use of this unit f\g or illegal operations by persons with malicious intent 3 Interf erence with or sto\gppage of this unit \gby persons with malicious int\gent It is your responsibility\g to take precautions such\g as those described below to protect yourself against the\g above network security risks. p Use this unit in a\g netw ork secured by a firewall, etc. p If this unit is co\gnnected to a netw ork that includes personal computers\g, make sure that the sy\gstem is not infected by computer viruses or other mali\gcious entities (using a regularly updated antivirus program, anti-spyware program, etc.). p Protect y our network against unauthorized access by restricting users to tho\gse who log in with \gan authorized user name and password. p Apply measures suc\gh as user authenti\gcation to protect \g y our network against leakage o\gr theft of information, including image data \gand authentication \ginformation (user names and passwords). p Do not install the\g camer a in locations whe\gre the camera or the cables can be destroyed or damaged by persons with malicious intent. U\fage re\ftriction\f Use of the same se\ggment is recommended\g for the network in which the unit \gand the controller \gor personal comput\ger are connected. If the equipment u\gses connections wi\gth different segments, events based on the s\gettings inherent to\g the network equipment, for instance, may occur so check this thoroughly prior to operation.