Page 11
10English For BatteriesThe frequency of use for batteries is approximately 300 measurements (3 times per day) with fresh Panasonic alkaline batteries (AAA-size LR03 alkaline batteries). [Measurement conditions: Room temperature 73.4 °F (23 °C); Pressurized to 170 mmHg; Wrist circumference: 6-3/4˝ (17 cm)] If batteries other than alkaline batteries are used or batteries are used in a cold room, and when measuring a person with high blood pressure, battery life may be dramatically shorter. *Use...
Page 12
11English 4 Adjust in order of “month”, “day”, “hour”, and “minutes”, repeating steps 2 and 3. The clock is stopped while the date or time is flashing. • “Month” “Day”“Hour” “Minute” 5 Press the Off/On Start button to turn off the unit. Note) During the setting if the Off/On Start button is pressed, or if no button is pressed for 5 minutes, the settings made up to that point will be used. * Setting range for years is from 2010 to 2050. Use the tip of a ballpoint pen etc. to press the Set...
Page 13
12English Fitting the Pressure Cuff Blood pressure is measured at your left wrist. It is not necessary to roll up your sleeve or to remove any clothing. Fastener Fastener Place the device on the inside of your wrist. Wrap the pressure cuff so that the positioning mark is aligned with the base of the wrist. 1. Place the device on the inside of your wrist.Place the device directly in contact with the skin. The device can be used by people with a wrist circumference of 5˝–8-3/4˝ (12.5–22.0 cm)....
Page 14
13English Fitting the Pressure Cuff (cont.) Do not remove the hook-and-loop fastener by twisting it off. Be sure to peel it in an horizontal direction in alignment with the cuff. Fit as shown in the figure. The cuff can be used on either wrist. However, the difference in blood pressure between the left and right wrists may be around 10 mmHg, so be sure to always use the same wrist for measurements.
Page 15
14English Obtaining Accurate Measurements Always take your blood pressure at the same time while sitting in the same position and using the same wrist. It is recommended to check your blood pressure at least twice a day. It is best in the morning before breakfast and in the evening after work. In the following situations, accurate measurements cannot be taken. Within 1 hour after eating or drinking alcohol Immediately after drinking coffee or tea, or smoking In a moving vehicle Immediately after...
Page 16
15English Obtaining Accurate Measurements (cont.) Do not take measurements in the positions shown below as they will be inaccurate. Do not bend your wrist inward. Do not clench your fist. If the device is placed at a height lower than the heart then the resulting readings may be higher than your actual blood pressure.If the device is placed at a height higher than the heart then the resulting readings may be lower than your actual blood pressure.If you lean forward while taking measurements...
Page 17
16English Wrist Height Sensor About the wrist height sensorThis is a support function to ensure that you use the blood pressure monitor at an appropriate height (same height as your heart). Users with a fixed measurement position and measurement environment (height of table, height of chair, etc.) can achieve more stable measurement conditions by using this function. It will estimate the height of the blood pressure monitor wrapped around the wrist from the angle of the arm, and notify you of the...
Page 18
17English Wrist Height Sensor (cont.) Setting the Height 1. Place the arm to which the device is attached on top of the storage case with the wrist positioned at the level of the heart. Height sensor setting display 2. Press the wrist height button for 3 seconds or longer. It will notify by flashing the wrist height sensor lamp 3 times. 3. Press the Off/On Start button to turn off the unit. Once the height is set, the range of appropriate height (where the wrist height sensor lamp turns on)...
Page 19
18English Clearing the Height Setting 1. Press the Memory/Recall button. Height sensor off display 2. Press the wrist height button for 3 seconds or longer. It will notify by flashing the wrist height sensor lamp 3 times. 3. Press the Off/On Start button to turn off the unit.
Page 20
19English Measuring Your Blood Pressure 1. Place the arm to which the device is attached on top of the storage case with the wrist positioned at the level of the heart. (Please see “Obtaining Accurate Measurements” on pages 14 and 15.) 2. Press the wrist height button briefly. Wrist height sensor function will start. (For wrist height sensor, see pages 16 and 17.) (Measurement will not start until the Off/On Start button is pressed.) Note: Height setting is reset when it is pressed for...