    							10English
    For	BatteriesThe frequency of use for batteries is approximately 300 measurements 
    (3 times per day) with fresh Panasonic alkaline batteries (AAA-size LR03  alkaline batteries). [Measurement conditions: Room temperature 73.4 °F  (23 °C); Pressurized to 170 mmHg; Wrist circumference: 6-3/4˝ (17 cm)]
    If batteries other than alkaline batteries are used or batteries are used 
    in a cold room, and when measuring a person with high blood pressure, 
    battery life may be dramatically shorter. 
    *Use alkaline batteries. (Panasonic Oxyride batteries can also be used.)
    Be sure to replace batteries once a year to prevent battery leakage.
    	Setting	the	 Time	and	Date
    *  Having inserted the batteries, set the time and date so that any future 
    stored measurements are saved in the memory with the correct time and 
    date. 
    (If you attempt to take measurements without first setting the time and 
    date then “—” will be displayed.)
    1 
    Set 2 
    Adjust
    3 
    Fix
    “Year”
    1	 Press	and	hold	the	Set	button	
    “1”	on	
    the	top	side	of	the	unit. Set the “year”.
    2	 Press	the
     	Adjust	button	 “2”	to	adjust	
    the	number. Each press of the button raises the 
    number of the “year”.
    Setting range for years is from 2010 to 
    2050.
    3	 Press	 the
    
    	Set	button	 “1”	to	fix	the	
    number. The “year” will be fixed. Then, set the 
    “month”.
    •
    •
    •
    •
    •
    •
    • 
    						
    							11English
    4	 Adjust	in	order	of	“month”,	“day”, 	
    “hour”, 	and	 “minutes”, 	repeating	 steps	
    2	and	3. The clock is stopped while the date or 
    time is flashing.
    •
    “Month”
    “Day”“Hour” “Minute”
    5	 Press	the	Off/On	Start	button	to	turn	
    off	the	unit.
    Note) During the setting if the Off/On Start button is pressed, or if no  button is pressed for 5 minutes, the settings made up to that 
    point will be used. 
    * Setting range for years is from 2010 to 2050.
    Use the tip of a ballpoint pen 
    etc. to press the Set and Adjust 
    buttons.
    	Setting	the	 Time	and	Date	(cont.) 
    						
    							12English
    	Fitting	the	Pressure	Cuff
    Blood pressure is measured at your left wrist. It is not necessary to roll up 
    your sleeve or to remove any clothing.
    Fastener
    Fastener
    Place the device 
    on the inside of 
    your wrist.
    Wrap the pressure cuff so 
    that the positioning mark is 
    aligned with the base of the 
    wrist.
    1.	 Place	the	device	on	the	inside	of	your	wrist.Place the device directly in 
    contact with the skin.
    The device can be used by 
    people with a wrist 
    circumference of 5˝–8-3/4˝ 
    (12.5–22.0 cm).
    •
    •
    Base of the wrist
    Wrap the pressure 
    cuff so that the 
    positioning mark 
    will be at the 
    center of the wrist. 2.	 Firmly	wrap	and	fasten	 using	
    the	hoop	and	loop	fastener. A loosely applied pressure 
    cuff will result in high blood 
    readings or incapable 
    measurement.
    Press fastener softly to avoid 
    the peel off.
    •
    • 
    						
    							13English
    	Fitting	the	Pressure	Cuff	(cont.)
    Do not remove the hook-and-loop 
    fastener by twisting it off. 
    Be sure to peel it in an horizontal 
    direction in alignment with the cuff. 
    Fit as shown in the figure.
    The cuff can be used on either wrist. 
    However, the difference in blood 
    pressure between the left and right 
    wrists may be around 10 mmHg, so 
    be sure to always use the same wrist 
    for measurements. 
    						
    							14English
    	Obtaining	Accurate	Measurements
    Always	take	your	blood	pressure	at	the	same	time	while	
    sitting	in	the	same	position	and	using	the	same	wrist.
    It is recommended to check your blood pressure at least twice a day. It is 
    best in the morning before breakfast and in the evening after work.
    In	the	following	situations, 	accurate	measurements	cannot	be	taken.
    Within 1 hour after eating or drinking alcohol
    Immediately after drinking coffee or tea, or smoking
    In a moving vehicle
    Immediately after exercising or taking a bath 
    (Wait at least 20 minutes and take a measurement while staying quiet.)
    In cold places 
    [Take measurements at room temperatures around 68 °F (20 °C).]
    When you need to urinate 
    (Wait several minutes after urinating before taking measurements.)
    Always	rest	for	four	to	five	minutes	before	taking	your	blood	
    pressure.
    Taking	measurements	while	sitting	down
    1.	 Place	your	elbow	on	the	table.
    2.	 Align	the	device	with	the	level	of	 your	heart.
    3.	 Open	and	relax	your	hand	with	 the	palm	facing	up.
    Please place your arm on top of the 
    storage case once you have attached 
    the pressure cuff.
    •
    •
    •
    •
    •
    • 
    						
    							15English
    	Obtaining	Accurate	Measurements	(cont.)
    Do not take measurements in the positions shown below as they will be 
    inaccurate.
    Do not bend your wrist inward. Do not clench your fist.
    If the device is placed at 
    a height lower than the 
    heart then the resulting 
    readings may be higher 
    than your actual blood 
    pressure.If the device is placed at 
    a height higher than the 
    heart then the resulting 
    readings may be lower 
    than your actual blood 
    pressure.If you lean forward while 
    taking measurements 
    then the resulting 
    readings may not be 
    accurate.
    To obtain accurate readings, the following actions should also be avoided 
    during measurements.
    Do not touch the device.
    Do not change position or move your wrist or fingers.
    Do not talk.
    [CAUTION]Keep away from cellular telephones and other sources of electromagnetic 
    radiation during measurements. 
    Failure to do so could result in blood pressure monitor malfunctioning. •
    •
    • 
    						
    							16English
    	Wrist	Height	Sensor
    About	the	wrist	height	sensorThis is a support function to ensure that you use the blood pressure 
    monitor at an appropriate height (same height as your heart). Users with 
    a fixed measurement position and measurement environment (height 
    of table, height of chair, etc.) can achieve more stable measurement 
    conditions by using this function. 
    It will estimate the height of the blood pressure monitor wrapped around 
    the wrist from the angle of the arm, and notify you of the appropriate 
    measurement position with the wrist height sensor lamp. 
    (When a reading is saved, whether or not wrist height was appropriate at 
    the time of measurement is also saved. This information is then indicated 
    by the wrist height sensor lamp when recalling readings.)
    When	the	height	 is	not	 appropriateWhen	the	height	is	appropriate
    Wrist is lower 
    than heart Wrist is higher 
    than heartAppropriate height
    (wrist is approximately at the height  of heart) 
    1
      Wrist height sensor lamp
    Flashes 1
     
    Wrist height sensor lamp
    Is lit
    2
      Graph display
    Upward arrow Downward arrow 2
     
    Graph display
    Displaying appropriate position
    Wrist	height	sensor	lamp	will	turn	off	a	short	period	after	the	
    blood	pressure	measurement	starts. 	
    •
    • 
    						
    							17English
    	Wrist	Height	Sensor	(cont.)
    Setting	the	Height
    1.	 Place	the	arm	to	which	the	device	is	attached	on	top	of	the	storage	case	with	
    the	wrist	positioned	at	the	level	of	the	
    heart.
    Height sensor setting 
    display
    2.	 Press	the	wrist	height	button	for	3	seconds	or	longer.
    It will notify by flashing the wrist height 
    sensor lamp 3 times.
    3.	 Press	the	Off/On	Start	button	to	turn	off	the	unit.
    Once the height is set, the range of appropriate height (where the wrist 
    height sensor lamp turns on) becomes narrow in comparison to when it 
    is not set, making it easier to adjust to appropriate height.
    • 
    						
    							18English
    Clearing	the	Height	Setting
    1.	 Press	the	Memory/Recall	button.
    Height sensor off display
    2.	 Press	the	wrist	height	button	for	3	seconds	or	longer.
    It will notify by flashing the wrist height 
    sensor lamp 3 times.
    3.	 Press	the	Off/On	Start	button	to	turn	off	the	unit. 
    						
    							19English
    	Measuring	Your	Blood	Pressure
    1.	 Place	the	arm	to	which	the	device	is	
    attached	on	top	of	the	storage	case	with	
    the	wrist	positioned	at	the	level	of	the	
    heart.	
    (Please	see	 “Obtaining
    
    	Accurate	
    Measurements” 	on	pages	14	and	15.)
    2.	 Press	the	wrist	height	button	briefly.
    Wrist height sensor function will start. 
    (For wrist height sensor, see pages 16 and 
    17.) 
    (Measurement will not start until the Off/On 
    Start button is pressed.)
    Note:   Height setting is reset when it is pressed 
    for 3 seconds or longer.
    •
    3.	 Fine	adjust	the	arm	angle.
    Fine adjust the angle of your arm so the 
    wrist will be at the appropriate height. 
    Wrist height sensor lamp will turn on when 
    your wrist is at an appropriate height. 
    (Please see pages 16 and 17.)
    Wrist height sensor lamp will turn off a 
    short period while after the measurement 
    starts.
    You can also start measurement by 
    proceeding to the step “4. Press the 
    Off/On Start button.” without pressing the 
    wrist height button. In such a case, both 
    the blood pressure measurement and 
    the wrist height sensor function will start 
    simultaneously.•
    •
    • 
    						