25(EN) Temp range 4Select the item and set to []. ▲ ▼ → ◄ ► → 5 Set the temperature range. ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.) Setting range • Cool/Dry: 18 °C to 30 °C • Heat: 16 °C to 30 °C • Auto: 17 °C to 27 °C To set in series Repeat from step 4 without pressing . Note • Temp auto return When [Return type] is set to [Saving], this functions only when the temperature set in step 5 saves more energy than the changed temperature. e.g. When Cool 26 °C is set and the temperature is changed to 28 °C • [Saving]: Keeps 28 °C • [Normal]: Returns to 26 °C • The temperature range that can be set varies depending on the model.
26(EN) Energy Saving Auto shutoff When the operation is stopped at a specifi ed time (e.g. closing time) and resumed afterwards, this function detects the operation status at regular time intervals and stops operation automatically. Detect the operation status at regular time intervals and stop the operation automatically. (e.g. 60 min) ON OFF 21:00 22:08DetectDetect Detect 23:009:00 60 min 60 min 60 min Closing timeOpening time Auto shutoff in effect Leaves the shop without turning off A/C.If operation is detected... automatically stops. Returns to get something left behind and turns on A/C Auto stop 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Energy saving]. ▲ ▼ → 3Select [Auto shutoff] and set to []. ▲ ▼ → ◄ ► → 4 Select the item to set. ▲ ▼ →
27(EN) Stop time Time to stop operation (Time when Auto shutoff is activated) 5 Set. hour minute ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.) End time Time when Auto shutoff stops 5 Set. hour minute ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.) Timer Time interval to detect operation status after [Stop time] 5 Set. ▲ ▼ → → (Press 2 times to fi nish.) • 10 min to 180 min (by the 10 min)
28(EN) Energy Saving Schedule peak cut This reduces the operation capacity for the specifi ed time period. 1 Display the menu screen. To return to the last screenPress . To return to the top screenPress 2 times. 2 Select [Energy saving]. ▲ ▼ → 3 Select [Schedule peak cut]. ▲ ▼ → 4 Enter the password. ▲ ▼ → ► → (Repeat) 5Set [Select enable/disable] to []. ▲ ▼ → ◄ ► 6 Select [Set schedule]. ▲ ▼ → 7 Change the setting. Select the fi eld to register. ▲ ▼ → Large Small 11:00 13:00 16:00 19:00 Time zone to reduce the operation capacity Operation capacity
29(EN) 8 Set the start time and end time. ▲ ▼ → ► → ▲ ▼ → (Repeat) 9 Select the operation capacity. ▲ ▼ → → (Press 2 times to fi nish.) To set in seriesRepeat from step 4 without pressing . To change• Select the fi eld to change in step 7 above. • Select [Change]. ▲ ▼ → • Following the above steps 8 to 9, select the start time, end time and operation capacity. To delete• Select the fi eld to delete in step 7 above. • Select [Delete]. ▲ ▼ → • Select [YES]. ◄ ► → → (Press 2 times to fi nish.)
30(EN) Energy Saving Repeat off timer This stops operation after a certain period of time each time operation is performed. (e.g. When forgetting turning off) 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Energy saving]. ▲ ▼ → 3 Select [Repeat off timer] and set to [ ]. ▲ ▼ → ◄ ► → 4 Set the timer to stop. ▲ ▼ → → (Press 2 times to fi nish.) • 10 min to 180 min (by the 10 min) ON OFF 60 min Finishes working without turning off A/C.Turns on A/C. Starts working.Auto stop (e.g. Setting to stop operation after 60 minutes)
31(EN) Outing Function This function prevents the room temperature from rising too high (or dropping too low) when no one is in the room due to outing, etc. • • • • •
32(EN) Outing Function 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Outing function] ▲ ▼ → 3 Select [Select enable/disable] and set to [ ]. ▲ ▼ → ◄ ► → 4 Select [Set lower/upper limit temp.]. ▲ ▼ → 5 Set the temperature range. ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.)
33(EN) Initial Settings Clock Clock type Operation lock 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Initial settings]. ▲ ▼ → 3 Select the item to set. ▲ ▼ → Clock 4 Set the date and time. ▲ ▼ → ► → → (Repeat) Clock type 4 Select the type to display. ▲ ▼ → → (Press 2 times to fi nish.) AM/PM 24 h Operation lock 4 Select the type of lock and set to [ ]. ▲ ▼ → ◄ ► → (Press 2 times to fi nish.) To cancel lock Select [-] in step 4. Only for [Lock all keys] Select [YES]. ◄ ► → (Press 2 times to fi nish.)
34(EN) Initial Settings The room to which the remote controller belongs can be easily identifi ed. 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Initial settings]. ▲ ▼ → 3 Select [Controller name]. ▲ ▼ → 4 Enter the name. (Repeat the same procedure for all characters.) ▲ ▼ → ◄ ► → • Up to 16 characters. (Space is included in the number of characters.) To change the character type Select the character type with ▲ ▼ ◄ ► and press . Character type To enter space Select [Space] with ▲ ▼ ◄ ► and press . To delete 1 character Select [BS] with ▲ ▼ ◄ ► and press . 5 Select [Conf]. ▲ ▼ ◄ ► → → (Press 2 times to fi nish.) Controller name