      If [Sleeping] button does not work.
    Or, in the case of operation not being started even if [SET] is pressed.
    Check the following table.
    ItemDisplay of the remote control unit
    (Lighting/fl ashing indication)Contents
    1
     The Error indication fl ashes 
    (for several seconds).The clock is not set.
    2
     “This function is not available” indication 
    lights up (for several seconds).When the operation mode is set to AUTO or 
    FAN, this function is not available.
    3
     Centralized control indication fl ashes 
    (for several seconds).The centralized control device is prohibited 
    from starting/stopping the unit or changing the 
    temperature setting.
    The sleeping function operation will be cancelled in the following cases:
    1:  When the unit is operated to stop or change the temperature setting by the other remote 
    control unit or centralized control device.
    2:  When the unit is operated to stop or change the temperature setting with the weekly program 
    function / outing function.
    3:  When the centralized control unit is prohibited from stopping the unit or changing the 
    temperature setting.
    Note
    Trouble Possible Cause/Remedy
    The temperature setting does not 
    decrease (increase).The temperature over the upper or lower limit or each operation 
    mode cannot be set.
    Operation under the sleeping function 
    does not fi nish.Note if you change the time after the sleeping function started. The 
    operation does not fi nish until it reaches to the set starting time. 
    						
    							22(EN)
    ECONAVI Function
    This function is available by attaching an optional ECONAVI sensor.
    The ECONAVI sensor detects human activity and conserves energy based on the 
    activity level. 
    Overview of the ECONAVI function
    High activity• Cooling:  Target temperature is the same as the set temperature.
    • Heating:  Target temperature is 1 °C lower than the set 
    temperature.
    Low activity• Cooling:  Target temperature is 1 °C higher than the set 
    temperature.
    • Heating:  Target temperature is the same as the set temperature.
    No one in the room No one in the room for 20 minutes
    • Cooling:  Target temperature is 2 °C higher than the set 
    temperature.
    • Heating:  Target temperature is 2 °C lower than the set 
    temperature.
    No one in the room for 3 hours
    • Cooling:  Cooling will stop and the unit will be in fan only mode.
    • Heating:  Heating will stop and the unit will be in fan only mode. * When the sensor 
    detects movements in 
    the room which have 
    been empty, it will 
    resume operation to 
    match with the activity 
    level.
    Note
      Even when target temperature is changed through the ECONAVI function, the set 
    temperature shown in the remote controller does not change.
       Even when Cooling/Heating is changed to Fan through the ECONAVI function, 
    the operation mode shown in the remote controller will still be Cooling/Heating.
      It is possible to choose from the following options for the operation to be 
    performed after a lapse of 3 hours since the room has been empty.
    •  Operates in the Fan mode only.
    •  Stops and resumes operations after human movements are detected.
    • 
    Stops and will not resume operations even after human movements are detected.
    •  Continues to operate in the current mode.
    If you need to do so, please contact the dealer. 
    						
    							23(EN)
    ECONAVI Function
    Using the remote controller, you can switch the ECONAVI function ON/OFF.
    1
    Press [ECONAVI] to ON the 
    ECONAVI function.
    * When ECONAVI is enabled,  
    will appear.
    
    1 / 2
    2
    Press [ECONAVI] to OFF.
    * When the indoor unit is stopped,  will disappear.
    ON/OFF setting of ECONAVI function
    Note
      Turn the ECONAVI function OFF if:
    -  You want to maintain the room temperature at a set temperature.
    -  You want to keep air conditioner running while nobody is in a room.
    -  The sensor fails.
    -  Only infants, babies, or people only with disabilities are in the room.
     WARNING
    Do not use the ECONAVI function in a room with disabled persons or infants only. 
    Due to their limited motions, the ECONAVI sensor may judge no person is present, 
    causing the indoor unit to stop the operation. 
    						
    							24(EN)
    Blackout?
      After recovery from blackout, press 
    [Start/Stop] again.
      àIf operation does not start, turn off the circuit 
    breaker and consult the dealer of purchase 
    about the symptom and Model No.
    Is the circuit breaker 
    turned off?   Turn it on and press [Start/Stop] again.   àIf operation does not start, turn off the circuit 
    breaker and consult the dealer of purchase 
    about the symptom and Model No.
    Is  blinking? 
      After blinking stops, press [Start/Stop] 
    again.
      àIf operation does not start, turn off the circuit 
    breaker and consult the dealer of purchase 
    about the symptom and Model No.
    Is  displayed?
      If any of the following alarm indications 
    appears, stop operation once and restart 
    approx. 1 minute later.
    (Alarm indication, off)
    [•E04  •E06  •P10  •P20  •H06]
      àIf the indication does not reappear, use the unit.
      àIf the indication reappears or an alarm 
    indication other than the above (combination of 
    numbers and characters such as E, F, H, L and 
    P) appears, stop operation, turn off the circuit 
    breaker and consult the dealer of purchase 
    about alarm indication, Model No. and indoor 
    unit No.
    Cannot stop the 
    operation.
    Or the unit starts to 
    run automatically 
    even if [Start/Stop] 
    (Off) is pressed.
      Check if the outing function is activated or not. 
    (
    )
      Check control by central control device.
    Troubleshooting
    If operation does not start by pressing [Start/Stop] button ...
    Check the following before asking for repair. 
    						
    							25(EN)
    The remote 
    controller screen 
    displays a fl ashing 
    “ 
     ”.
      Faulty sensor or incorrect installation. Turn OFF the ECONAVI function with the 
    remote controller and contact the retailer or 
    point of purchase with the Model No. and 
    problem.
    The remote 
    controller screen 
    does not display the 
     
    .
      The indoor unit has stopped. Turn on the 
    indoor unit.
      The unit is in Fan mode. The ECONAVI 
    function does not operate in Fan mode.
      The ECONAVI function is set to OFF. Turn 
    the ECONAVI function ON with the remote 
    controller.
      The indoor unit may not support the 
    ECONAVI function. If you turn the 
    ECONAVI function ON with the remote 
    control but there is no change, the indoor 
    unit does not support the ECONAVI 
    function.
    Please contact the dealer.
    •  If you need to contact for servicing, check the back cover of the operating instructions for indoor 
    units or outdoor units. 
    						
    							26(EN)
    Specifi cations
    Model No. CZ-RTC4
    Dimensions (H) 120 mm x (W) 120 mm x (D) 20 + 4.75 mm
    Weight 160 g
    Temperature/
    Humidity range 0 ˚C to 40 ˚C / 20 % to 80 % (no condensation)
    *Indoor use only.
    Power Source DC16 V (supplied with indoor unit)
    Clock Precision
    ± 30 seconds/month (at normal temperature 25 
    ˚C) 
    *Adjust periodically.
    Holding 
    time 24 hours (when fully charged)
    *Approx. 8 hours are required for full charge.
    Number of 
    connected indoor 
    units Up to 8 units
    © Panasonic Corporation 2015 
    						
    							Panasonic Corporation
    1006 Kadoma, Kadoma City, Osaka, Japan
    Operating Instructions
    High-spec Wired Remote Controller
    Model No. CZ-RTC3
    Installation Instructions
    Separately Attached.
    ENGLISHBefore operating the unit, read these operating instructions thoroughly \
    and keep them for future 
    reference.
    CV6233312187
    WEB-URL Panasonic Corporation  
     Website:http://panasonic.net/ 
    						
    							2(EN)
    Part Names Control panel
    Note
    LCD screen   Return button
    Returns to the previous screen.Menu buttonDisplays the menu 
    screen (P. 10).
    Operation indicatorIlluminates during operation.
    Blinks during alarm. 
    Start/Stop buttonStarts/Stops operation.
    Enter buttonFixes the selected content.
    Press centre No glove No pen
    Energy saving 
    button
    Switches Energy 
    saving/Normal 
    operation.
    Cross key buttonsSelects an item.Up
    DownRight Left 
    						
    							3(EN)
    Safety Precautions
    CAUTIONS
    This appliance is intended to be used by expert or 
    trained users in shops, in light industry and on farms, or 
    for commercial use by lay persons.
    This appliance can be used by children aged from 8 
    years and above and persons with reduced physical, 
    sensory or mental capabilities or lack of experience 
    and knowledge if they have been given supervision or 
    instruction concerning use of the appliance in a safe 
    way and understand the hazards involved.
    WARNING
    Do not use this appliance in a potentially explosive 
    atmosphere.
    •  Do not operate with wet hands.
    •  Do not wash with water.
    In case of malfunction of this appliance, do not repair by 
    yourself. Contact the sales or service dealer for repair.
    In case of emergency, remove the power plug 
    from the socket or switch off the circuit breaker 
    or the means by which the system is isolated 
    from the mains power.
     WARNINGCAUTION
    This symbol refers to a hazard or unsafe 
    practice which can result in severe personal 
    injury or death. This symbol refers to a hazard or unsafe 
    practice which can result in personal injury or 
    product or property damage.
    Matters to be observedProhibited matters 
    						
    							4(EN)
    Note:
      This device complies with Part 15 of the FCC Rules. 
    Operation is subject to the following two conditions: (1) This 
    device may not cause harmful interference, and (2) this 
    device must accept any interference received, including 
    interference that may cause undesired operation.
      This equipment has been tested and found to comply with 
    the limits for a Class B digital device, pursuant to Part 15 
    of the FCC Rules. These limits are designed to provide 
    reasonable protection against harmful interference in a 
    residential installation. This equipment generates, uses 
    and can radiate radio frequency energy and, if not installed 
    and used in accordance with the instructions, may cause 
    harmful interference to radio communications. However, 
    there is no guarantee that interference will not occur in a 
    particular installation. If this equipment does cause harmful 
    interference to radio or television reception, which can be 
    determined by turning the equipment off and on, the user is 
    encouraged to try to correct the interference by one or more 
    of the following measures:
    •  Reorient or relocate the receiving antenna.
    • 
    Increase the separation between the equipment and receiver.
    •  Connect the equipment into an outlet on a circuit different 
    from that to which the receiver is connected.
    •  Consult the dealer or an experienced radio/TV technician 
    for help.
      FCC Caution: To assure continued compliance, follow 
    the attached installation instructions.  Any changes 
    or modifi cations not expressly approved by the party 
    responsible for compliance could void the user’s authority 
    to operate this equipment.
    Safety Precautions 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cz Rtc4cz Rtc3 Operating Instructions Manual