Home > Panasonic > Remote Control > Panasonic Cz Rtc4cz Rtc3 Operating Instructions Manual

Panasonic Cz Rtc4cz Rtc3 Operating Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cz Rtc4cz Rtc3 Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11(EN)
    Changing the Program Timer
    To set the weekly program, follow the steps.
    1
    Select the program you want to 
    set in the program confi rmation 
    mode, and press [SET]. This enters 
    the setting mode of the program 
    currently displayed.
    * In the program setting mode, [SETTING], 
    “hour”, “minute”and “item”  fl ash on the 
    display.
    
    2 / 3 / 4
    4 1 / 2 / 3 / 4
    Program step1
    Program step2
    2
    Set the “hour”. (Program step 1)
    Press [▼/▲] to set the “hour”.
    Confi  rm the “hour” and press [SET]. This 
    enters the program changing mode 
     
    (setting of the “minute”).
    3
    Set the “minute”. (Program step 2)
    Press [▼/▲] to set the “minute”.
    Confi  rm the “minute” and press [SET]. 
    The unit enters 
     (the program pattern 
    selection mode).
    SET
    SET SET SET
    CANCEL,DEL
    normal remote controller
    program check
    PROGRAM CANCEL
    CANCEL,DEL
    CANCEL
    PROGRAM
    SET,CANCEL,DEL
    SET,CANCELProgram Changing hour digits
    Changing minute digits
    Changing patterns
    Selecting copy source
    Selecting copy destination
    Weekly Program Function 
    						
    							12(EN)
    4
    Set the program pattern. (Program step 3)
    There are 4 program patterns. 
    Pressing [▼/▲] repeats the following display patterns.
    ÃÃ
    Pattern 1 (Default display)
    [▼]
    [▼]Pattern 2
    [▲]
    [▲] Pattern 4[▲][▲]
    Pattern 3 [▼][▼] The indoor unit starts operation at the 
    programmed time.
    The indoor unit starts operation at the 
    programmed time and changes the 
    temperature settings.
    The indoor unit stops operation at the 
    programmed time.
    The indoor unit changes the 
    temperature setting at the 
    programmed time.
    For Pattern 3 and Pattern 4: Press [/] to change the temperature setting.
    5
    Select the program pattern and press [SET]. 
    The program timer setting is confi rmed and the unit enters the confi rmation mode 
    .
    Note
      If you press [CANCEL] during the setting, it returns to the program confi rmation 
    mode.
      If there is no operation made for 10 minutes during the setting, it returns to the 
    normal mode.
    In this case, all the settings in progress will be invalid.  
    						
    							13(EN)
    Note
      After deleting, the unit returns to the program confi rmation mode .
       
    If you press [CANCEL] during the setting, the unit returns to the program 
    comfi rmation mode.
       
    If there is no operation made for 10 minutes during the setting, the unit returns to 
    the normal mode. To delete the program timer setting, follow the steps below.
    1
    Press [PROGRAM] to enter the 
    program confi rmation mode.
    
    4 1 5 2 / 3
    2
    Press [▼/▲] to select the day of the 
    program you want to delete.
    Press [SET] to fi x the day.
    3
    Press [▼/▲] to select a TIMER No. 
    (from 1 to 6).
    4
    Press [SET] to display the program 
    setting mode 
    .
    5
    Press [DELETE] to delete the 
    program.
    Weekly Program Function
    Deleting the Program Timer 
    						
    							14(EN)
    Weekly Program Function
    Invalidating the Program Timer
    If you want to stopping the program operation for more than 1 week, you can invalidate 
    all the timer settings.
    Once the timer settings are invalidated, the program will not be operated until the 
    invalidation is cancelled.
    How to invalidate the program timer 
    1.  Press and hold [CANCEL]([TIMER 
    OFF]) for more than 2 seconds.
    [TIMER OFF] is displayed and the programs will 
    be invalidated from the next one.
    
    1
    How to cancel the program timer invalidation
    1.  Press and hold [CANCEL]([TIMER 
    OFF]) for more than 2 seconds.
    [TIMER OFF] disappears and the programs will 
    be validated from the next one.
    
    1
      If Power Failure Occurred 
    If the power recovers in a short time period, the program after the recovered time will 
    be valid. 
    If more than one hour has passed for power return after power failure, the present time 
    information will be lost. In this case, the program will not be operated. 
    						
    							15(EN)
    You can duplicate the preset program by day.
      Select the copy source.
    1
    If [PROGRAM]([COPY]) is pressed 
    in program checking mode 
    , it 
    enters the copy mode (Selecting 
    the copy source 
    ) of the program 
    timer. 
    While in the copy mode of the program 
    timer, [SETTING] and  (day) of the copy 
    source fl ash on the display.
    
    1 2 / 4 3 / 4
    2
    Press [▼/▲] to select the day of the 
    copy source.
    Select the copy destination.
    3
    If [SET] is pressed in the mode of 
    selecting the copy source 
    , it 
    enters the copy mode (Selecting the 
    copy destination 
    ) of the program 
    timer.
    4
    Press [▼/▲] to select the day of the 
    copy destination. Then, press [SET] 
    to complete copying and return to 
    the program checking mode.
    Weekly Program Function 
    Note
    The program will be overwritten if the preprogrammed day is selected as a copy 
    source.
    Duplicating the Program Timer 
    						
    							16(EN)
    Before Asking Repair Work
    Before asking repair work, please check the following. 
    Trouble Possible Cause/Remedy
    “ERROR” is displayed 
    when the minute digits are 
    entered.If there is another TIMER No. which has the program of the same 
    time and same day, you cannot overlap the setting.
    The set data is not stored.The stored programs are automatically sorted by the time. Check if 
    the data is stored in the other TIMER No.
    Program does not 
    function.Check if the time indication is not “– – : – –”.
    When the time is invalid, the program is also invalid.
    Check the remote controller prohibition inside.
    In that case, the program is invalid.
    Weekly Program Function 
    						
    							17(EN)
    Outing Function
    Outing function is a function that prevents the room temperature from 
    increasing too much (or decreasing too much) when no one is in the room.
    An air conditioner works automatically if this function is set effective.
      
      
      
      
    •  
      
    •  
    • •  
     
    • 
     
      
     
     
    A remote controller may lose outing function operation information when it is cut for 
    more than 24 hours during the outing function operation by electricity. It reverts from 
    the blackout, and an air conditioner does not drive in outing function when operation 
    is started. At this time, an air conditioner does not stop at outing function. 
    						
    							18(EN)
    1
    Press and hold [Ventilation] for more 
    than 2 seconds to display 
    the upper limit temperature setting 
    screen.
    [SETTING], ,  and the upper limit 
    temperature start fl ashing.
    (The default value of the upper limit 
    temperature is 38 °C.)
    1 2 / 3 2 / 3
    Ã
    2      
    Ã
    3
    2
    Press [/] to select the upper 
    limit temperature, and press [SET] 
    to fi x the value. The lower limit 
    temperature setting screen is 
    displayed.
    3
    Press [/] to select the lower limit 
    temperature, and press [SET] to 
    fi x the value. The outing function 
    setting is completed. 
    (The default value of the lower limit 
    temperature is 10 °C.)
    *  The unit returns to the normal mode if [CANCEL] is pressed or there is no operation 
    made for 3 minutes during the setting. In this case, all the settings in progress will be 
    lost.
    Canceling the outing function
    1.  Press and hold [Ventilation] for more 
    than 2 seconds while the outing 
    function is set.
    
    1
    Outing Function
    Setting the Outing Function 
    						
    							19(EN)
    This function leads you to a comfortable sleep and changes the room temperature 
    during your sleep.
    •  You can set the off timer every one hour from 1 to 10 hours.
      Display of remote control unit (during the time setting)
    Sleeping function 
    indication
    Off time
    In case the present time is 23:00.
    Operating time
      Display of remote control unit (during sleeping function setting)
    Ã
    Sleeping function 
    indication
    *  If no operation is made for 3 minutes, the time setting mode will be automatically 
    fi nished.
    Sleeping Function 
    						
    							20(EN)
    Ex. In case of 7 hours timer
    1
    Press [Sleeping].
    •  Each time the button is pressed, the 
    indication changes in the following order.
    (every one hour)
    (Press [CANCEL] to stop the time setting.)
    
    211
    2
    Press [SET].
    •  The sleeping operation starts.
      When the off time comes:
    •  The indoor unit stops.
    *  The temperature returns to the setting at the time when sleeping function 
    operation started.
    To cancel the sleeping function operation
    1. Press [Sleeping].* The temperature setting remains at the time 
    cancelled.
    
    1
    •  The following buttons also cancel the sleeping function operation.
    [Start/Stop] button
    Stops the indoor unit after the sleeping function operation is cancelled.
    [Mode select] button
    Changes the operation mode after the sleeping function operation is cancelled. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cz Rtc4cz Rtc3 Operating Instructions Manual