Page 71
13.2. Relationship Between The Condition Of The Air Conditioner And Pressure And Electric Current Cooling ModeHeating Mode Condition of the air conditonerLow PressureHigh PressureElectric current during operationLow PressureHigh PressureElectric current during operation Insufficient refrigerant (gas leakage) Clogged capillary tube or Strainer Short circuit in the indoor unit Heat radiation deficiency of the outdoor unit Inefficient compression • Carry out the measurements of pressure, electric current,...
Page 72
14 Technical Data 14.1. Thermostat Characteristics 14.1.1. CS-W7DKE CS-W9DKE CS-W12DKE 72 CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Page 73
14.2. Sensible Capacity Chart 14.2.1. CS-W7DKE 230VOutdoor Temp. (°C) Indoor wet bulb temp.30354046 TCSHCIPTCSHCIPTCSHCIPTCSHCIP 17.0°C2.281.730.652.131.660.701.981.590.751.801.510.81 19.0°C2.300.71 19.5°C2.501.810.662.341.740.712.181.670.761.981.590.82 22.0°C2.731.880.672.551.810.732.371.740.782.161.660.84 14.2.2. CS-W9DKE 230VOutdoor Temp. (°C) Indoor wet bulb temp.30354046 TCSHCIPTCSHCIPTCSHCIPTCSHCIP 17.0°C2.732.070.782.551.980.842.371.910.902.161.810.97 19.0°C2.750.85...
Page 74
14.3. Operation Characteristics 14.3.1. CS-W7DKE CU-W7DKE 74 CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Page 77
15 Exploded View (Indoor Unit) 15.1. CS-W7DKE CS-W9DKE CS-W12DKE Note: The above explode d view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 77 CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Page 78
16 Replacement Parts List (Indoor Unit) 16.1. CS-W7DKE CS-W9DKE CS-W12DKE REF. NO.PART NAME & DESCRIPTIONQTY.CS-W7DKECS-W9DKECS-W12DKEREMARKS1CHASSY COMPLETE1CWD50C1377←←2FAN MOTOR1CWA921181←←03CROSS FLOW FAN COMPLETE1CWH02C1031←←4BEARING ASS’Y1CWH64K007←←5SCREW - CROSS FLOW FAN1CWH4580304←←6EVAPORATOR1CWB30C1597←CWB30C15837FLARE NUT1CWT25086(1/4”)←←8FLARE NUT1CWT25087 (3/8”)←CWT25096 (1/2”)9HOLDER SENSOR1CWH32143←←10DISCHARGE GRILLE COMPLETE1CWE20C2366←←11VERTICAL VANE9CWE241150←←12CONNECTING...
Page 79
17 Exploded View (Outdoor Unit) 17.1. CU-W7DKE CU-W9DKE Note: The above explode d view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 79 CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Page 80
17.2. CU-W12DKE Note: The above explode d view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 80 CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE