Page 1
1 Features 3 2 Functions 4 2.1. Remote Control 4 2.2. Indoor Unit 5 2.3. Outdoor Unit 6 3 Product Specifications 7 3.1. CS-W7DKE CU-W7DKE 7 © 2004 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-W7DKE CU-W7DKE CS-W9DKE CU-W9DKE CS-W12DKE CU-W12DKE 3.2. CS-W9DKE CU-W9DKE 9 3.3. CS-W12DKE CU-W12DKE 11 4 Dimensions 13 4.1. Indoor Unit & Remote Control 13 4.2. Outdoor Unit 14 5 Refrigeration Cycle...
Page 2
7 Wiring Diagram 18 8 Operation Details 20 8.1. Heating Operation 20 8.2. Cooling Operation 21 8.3. Soft Dry Operation 22 8.4. Automatic Operation 23 8.5. Operation Control 24 8.6. Indoor Fan Speed Control 30 8.7. Outdoor Fan Speed Control 32 8.8. Vertical Airflow Direction Control 32 8.9. Horizontal Airflow Direction Control 33 8.10. Powerful Operation 33 8.11. Quiet Operation 35 8.12. Ionizer Operation 37 8.13. Timer Control 38 8.14. Random Auto Restart Control 38 8.15....
Page 3
• High efficien cy. • Compact design. • W ider range of horizontal discharge air. • Air Filter with function to reduce dust and smoke. • Long installation piping up to 15 meter (CS/CU-W12DKE), 10 meter (CS/CU-W7DKE & CS/CU-W9DKE). • Supersonic Air Purifyin g System with Super Alleru-Buster. − Inactive various harmful airbone elements includin g allergens, viruses and bacteria. − Generated supersonic waves enhanc e the ability to collect dust and dirt in the air. • Quality Improvement − Random...
Page 4
2 Functions 2.1. Remote Control Operation Start / StopOFF / ON IRoom Temperature SettingTEMP. Operation Mode Selection •AUTOAutomatic Operation • HEATHeating Operation • COOLCooling Operation • DRYSoft Dry Operation MODE Time / Timer Setting • Hours and minutes setting. Clock Setting • Current time setting. Ionizer Operation Start / Stop Indoor Fan Speed SelectionFAN SPEED •Low Fan Speed • Medium Fan Speed • High Fan Speed • AUTOAutomatic Fan Speed Vertical Airflow Direction Control • 24-hour, OFF / ON...
Page 5
2.2. Indoor Unit Automatic Operation Button •Press for < 5 second to operate Automatic operation mode. Used when the remote control cannot be used. •Press for ≥ 5 second to operate Cooling operation mode and compressor force to on (“beep” sound will heard). Used when test running or servicing. •Within 20 second of Cooling operation, press continuously for 5 second to enter various setting mode. “beep, beep” sound will be heard. (Used to toggle remote control signal receiving sound or select remote...
Page 6
2.3. Outdoor Unit •To protect compressor from reverse rotation when there is a instantaneous power failure. 60 Secs. Forced Operation Control •Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Overload Protector •OLP to protect the compressor. Overload Protector will trip when – Temperature of compressor increases to 120°C. – High temperature or high current flows to compressor. (Refer circuit diagram for OLP...
Page 7
3 Product Specifications 3.1. CS-W7DKE CU-W7DKE UnitCS-W7DKECU-W7DKE Cooling CapacitykW (kcal/h)2.30 (1,980) BTU/h7,840 Heating CapacitykW (kcal/h)2.45 (2,110) BTU/h8,350 Moisture Removall/h (Pint/h)1.5 (3.2) PhaseøSingle Power SourceVoltageV230 CycleHz50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeLom3/min (cfm)Cooling; 5.8 (203)— Heating; 6.3 (220) Mem3/min (cfm)Cooling; 6.9 (245)— Heating; 7.0 (250) Him3/min (cfm)Cooling; 7.9 (280)Cooling; 26.0 (920) Heating; 9.1 (320) SHim3/min...
Page 8
UnitCS-W7DKECU-W7DKE Power Cord Length Number of core-wirem1.9 3 (1.5 mm2)— — DimensionsHeightinch (mm)11 - 1/32 (280)20 - 3/32 (510) Widthinch (mm)31 - 15/32 (799)25 - 19/32 (650) Depthinch (mm)7 - 7/32 (183)9 - 1/16 (230) Net Weightlb (kg)20 (9.0)57 (26) CompressorDescription—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—600 Air CirculationDescriptionCross-flow FanPropeller Fan MaterialASG20k1PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW4768...
Page 9
3.2. CS-W9DKE CU-W9DKE UnitCS-W9DKECU-W9DKE Cooling CapacitykW (kcal/h)2.75 (2,370) BTU/h9,380 Heating CapacitykW (kcal/h)3.05 (2,620) BTU/h10,400 Moisture Removall/h (Pint/h)1.6 (3.4) PhaseøSingle Power SourceVoltageV230 CycleHz50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeLom3/min (cfm)Cooling; 5.8 (204)— Heating; 6.2 (220) Mem3/min (cfm)Cooling; 7.3 (257)— Heating; 7.3 (257) Him3/min (cfm)Cooling; 8.6 (300)Cooling; 26.0 (920) Heating; 9.7 (340) SHim3/min (cfm)Cooling; 9.7 (343)— Heating;...
Page 10
UnitCS-W9DKECU-W9DKE DimensionsHeightinch (mm)11 - 1/32 (280)20 - 3/32 (510) Widthinch (mm)31 - 15/32 (799)25 - 19/32 (650) Depthinch (mm)7 - 7/32 (183)9 - 1/16 (230) Net Weightlb (kg)20 (9.0)64 (29) CompressorDescription—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—700 Air CirculationDescriptionCross-flow FanPropeller Fan MaterialASG20k1PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW4768 RatedOutputW1530 Fan SpeedLowrpmCooling; 780— Heating; 840...