    							 1 Features 3
     2 Functions 
    4
     2.1. Remote Control 
    4
     2.2. Indoor Unit 
    5
     2.3. Outdoor Unit 
    6
     3 Product Specifications 
    7
     3.1. CS-W7DKE CU-W7DKE 
    7
    © 2004 Panasonic HA Air-Conditioning (M) Sdn Bhd
    (11969-T). All rights reserved. Unauthorized copying
    and distribution is a violation of law.
    CS-W7DKE CU-W7DKE
    CS-W9DKE CU-W9DKE
    CS-W12DKE CU-W12DKE
     3.2. CS-W9DKE CU-W9DKE 9
     3.3. CS-W12DKE CU-W12DKE 
    11
     4 Dimensions 
    13
     4.1. Indoor Unit & Remote Control 
    13
     4.2. Outdoor Unit 
    14
     5 Refrigeration Cycle Diagram 
    15
     6 Block Diagram 
    16
    Air Conditioner
    CONTENTS
     Page  Page
    Order No. MAC0408028C2 
    						
    							 7 Wiring Diagram 18
     8 Operation Details 
    20
     8.1. Heating Operation 
    20
     8.2. Cooling Operation 
    21
     8.3. Soft Dry Operation 
    22
     8.4. Automatic Operation 
    23
     8.5. Operation Control 
    24
     8.6. Indoor Fan Speed Control 
    30
     8.7. Outdoor Fan Speed Control 
    32
     8.8. Vertical Airflow Direction Control 
    32
     8.9. Horizontal Airflow Direction Control 
    33
     8.10. Powerful Operation 
    33
     8.11. Quiet Operation 
    35
     8.12. Ionizer Operation 
    37
     8.13. Timer Control 
    38
     8.14. Random Auto Restart Control 
    38
     8.15. Remote Control Signal Receiving Sound 
    38
     9 Operating Instructions 
    39
     10  Installation Instructions  
    45
     10.1. Safety Precautions 
    45
     10.2. Indoor Unit 
    48
     10.3. Outdoor Unit 
    52
     11  Installation And Servicing Air Conditioner Using R410A 
    55
     11.1. Outline 
    55
     11.2. Tools For Installing/Servicing Refrigerant Piping 
    56
     11.3. Refrigerant Piping Work 
    60
     11.4. Installation, Transferring, Servicing 
    62
     12  Servicing Information 
    66
     12.1. Distinction Of Lead Free (PbF) Printed Circuit Board 
    66
     12.2. Indoor Electronic Controllers Removal Procedures 
    66 12.3. Indoor Fan Motor And Cross Flow Fan Removal
    Procedures 
    67
     12.4. Remote Control Reset 
    68
     12.5. Auto OFF/ON Button 
    69
     13  Troubleshooting Guide 
    70
     13.1. Refrigeration Cycle System  
    70
     13.2. Relationship Between The Condition Of The Air
    Conditioner And Pressure And Electric Current 
    71
     13.3. Diagnosis Methods Of A Malfunction Of A Compressor
    And 4-way Valve 
    71
     14  Technical Data 
    72
     14.1. Thermostat Characteristics 
    72
     14.2. Sensible Capacity Chart 
    73
     14.3. Operation Characteristics 
    74
     15  Exploded View (Indoor Unit) 
    77
     15.1. CS-W7DKE CS-W9DKE CS-W12DKE 
    77
     16  Replacement Parts List (Indoor Unit) 
    78
     16.1. CS-W7DKE CS-W9DKE CS-W12DKE 
    78
     17  Exploded View (Outdoor Unit) 
    79
     17.1. CU-W7DKE CU-W9DKE 
    79
     17.2. CU-W12DKE 
    80
     18  Replacement Parts List (Outdoor Unit) 
    81
     18.1. CU-W7DKE CU-W9DKE 
    81
     18.2. CU-W12DKE 
    82
     19  Electronic Circuit Diagram 
    83
     19.1. Indoor Unit & Outdoor Unit 
    83
     19.2. Remote Control 
    89
     19.3. Print Pattern Indoor Unit Printed Circuit Board 
    90
     19.4. Print Pattern Indicator & Receiver Printed Circuit Board
     
    92
    2
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							 • High efficien cy.
     • Compact design.
     • W ider range of horizontal discharge air.
     • Air Filter with function to reduce dust and smoke.
     • Long installation piping up to 15 meter (CS/CU-W12DKE),
    10 meter (CS/CU-W7DKE & CS/CU-W9DKE).
     • Supersonic Air Purifyin g System with Super Alleru-Buster.
     − Inactive various harmful airbone elements includin g
    allergens, viruses and bacteria.
     − Generated supersonic waves enhanc e the ability to
    collect dust and dirt in the air.
     • Quality Improvement
     − Random auto restart after power failure for safety restart
    operation.
     − Gas leakage detection.
     − Prevent Compressor reverse cycle.
     − OLP to protect Compressor.
     − Noise prevention during soft dry operation.
     − Blue coated Conden ser for high resistance to corrosion.
     − Anti-dew formation control (Cooling & Soft Dry).
     − Overload protection control (Heating)
     − Outdoor fan control.
     − Compressor high pressure control. • Operation Improvement
     − Quiet mode to provide quiet operation.
     − Powerful mode to reach the desired room temperature
    quickly.
     − Ionizer control for generating negative ion in discharge
    air.
     − 24-hour timer setting.
     • Servicea bility Improvement
     − Removable and washable Front Panel.
     • Environmental Friendly
     − R410A, which does not contain chlorine , is used as its
    refrigerant, so there is no danger of damage to the
    ozone layer in Stratosphere.
    1 Features
    3
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							2 Functions
    2.1. Remote Control
    Operation Start / StopOFF / ON IRoom Temperature SettingTEMP.
    Operation Mode Selection
    •AUTOAutomatic Operation
    •
    HEATHeating Operation
    •
    COOLCooling Operation
    •
    DRYSoft Dry Operation
    MODE
    Time / Timer Setting
    • Hours and minutes setting.
    Clock Setting
    • Current time setting.
    Ionizer Operation Start / Stop
    Indoor Fan Speed SelectionFAN SPEED
    •Low Fan Speed
    •
    Medium Fan Speed
    •
    High Fan Speed
    •
    AUTOAutomatic Fan Speed
    Vertical Airflow Direction Control
    • 24-hour, OFF / ON Real Timer Setting.
    ON-TIMER
    OFF-TIMER
    Timer Operation Selection
    SET
    CANCEL
    Timer Operation Set / Cancel
    • ON Timer and OFF Timer setting and
    cancellation.
    CLOCK
    AIR SWING
    •AUTOAutomatic Vertical Airflow
    Control.
    • Manual Vertical Airflow
    Control (5 stages of
    adjustment).
    Powerful Operation Start / StopPOWERFUL
    Quiet Operation Start / StopQUIET
    Heating, Cooling, Soft Dry Operation.
    • Increase or decrease set temperature
    (16°C to 30°C)
    Automatic Operation
    •
    Operation with 2°C higher than
    standard temperature.
    • Operation with standard temperature.
    •
    Operation with 2°C lower than
    standard temperature.
    CANCEL
    OFF
    TIMERON
    TIMER
    FA N
    SPEED
    AIR
    SWINGAUTO
    HEAT
    DRY COOL
    MODE
    TIMER
    ON
    123
    OFF
    CLOCK RESET
    SET
    CANCEL
    TEMP
    POWERFULFAN SPEED
    AIR SWING
    OFF/ON
    QUIET
    
    
    4
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							2.2. Indoor Unit
    Automatic Operation Button
    •Press for < 5 second to operate Automatic
    operation mode. Used when the remote control
    cannot be used.
    •Press for ≥ 5 second to operate Cooling
    operation mode and compressor force to on
    (“beep” sound will heard). Used when test
    running or servicing.
    •Within 20 second of Cooling operation, press
    continuously for 5 second to enter various
    setting mode. “beep, beep” sound will be heard.
    (Used to toggle remote control signal receiving
    sound or select remote control transmission
    code).
    AUTO
    OFF / ON
    Operation Indication Lamps (LED)
    7 Minutes Time Save Control
    •To reduce the built up humidity inside the room.
    Anti-Dew Formation Control
    •Anti-Dew Formation Control for indoor unit
    discharge area.
    Timer Operation
    •Delay OFF/ON Timer control.
    Powerful Operation
    •Reaches the desired room temperature quickly.
    Anti-Freezing Control
    •To prevent indoor heat exchanger from freezing.
    Random Auto Restart Control
    •Unit will be restarted, when resume from power
    failure, at previous setting.
    Indoor Fan Speed Control
    •Manual control fan speed (High, Medium and
    Low).
    •Automatic fan speed.
    •Vertical airflow control can be adjusted
    automatically or manually by remote control.
    •Horizontal airflow can be manually adjusted by
    hand.
    Airflow Direction Control
    Time Delay Safety Control
    •Restarting is inhibited for appro. 3 minutes.
    Hot-Start Control
    •To prevent cold air being discharge during
    Heating operation starts.
    Starting Current Control
    •To reduce the starting current.
    Anti Cold Draft Control
    •To prevent the cold draft during Heating mode
    operation in thermo off condition.
    Operation Mode
    •Heating, Cooling, Soft Dry and Automatic
    Operation.
    30 Minutes Time Save Control
    •Heating operation only.
    Quiet Operation
    •To provide quiet operation.
    Ionizer Operation
    •Generate and discharge negative ion.
    •POWER (Green) ............. Lights up in operation,
    blinks in Automatic
    Operation judging and
    Hot Start operation.
    •TIMER (Orange) ............ Lights up in Timer
    Setting.
    •QUIET (Orange) ............. Lights up in Quiet
    Operation.
    •POWERFUL (Orange) ...... Lights up in Powerful
    Operation.
    •ION (Green) .................. Lights up in Ionizer
    Operation.
    •SUPER
    ALLERU-BUSTER
     (Blue) ... Lights up in operation.
    5
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							2.3. Outdoor Unit
    •To protect compressor from reverse
    rotation when there is a instantaneous
    power failure.
    60 Secs. Forced Operation Control
    •Once the compressor is activated, it
    does not stop within the first 60 secs.
    However, it stops immediately with
    remote control stop signal.
    Overload Protector
    •OLP to protect the compressor. Overload
    Protector will trip when
    – Temperature of compressor increases
    to 120°C.
    – High temperature or high current flows
    to compressor.
    (Refer circuit diagram for OLP
    characteristic)
    Compressor Reverse Rotation
    Protection Control
    Outdoor Fan Operation Control
    •Temperature Fuse.
    4-Way Valve Control
    •When the unit is switched to “OFF”
    during Heating Operation, 4-way valve
    stays at Heating position for 5 minutes.
    Overload Protection Control
    •Outdoor fan stops when indoor heat
    exchanger temperature rises to 51°C
    and above, and restarts when the indoor
    heat exchanger temperature drops to
    49°C and below.
    •Compressor stop when indoor heat
    exchanger temperature reaches 65°C or
    above. (Heating Operation Only)
    Deice Control
    •To prevent frosting at outdoor heat
    exchanger. (Only for Heating Operation)
    •
    Temperature of outdoor heat exchanger
    is sensed by TRS (Thermal Reed Switch).
    TRS OFF temperature 4°C.
    TRS ON temperature -3°C.
    Compressor Protection Control
    •If the outdoor fan motor is not running
    after compressor starts for 50 secs.,
    compressor will stop. (Cooling and Soft
    Dry Operation only).
    6
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							3 Product Specifications
    3.1. CS-W7DKE CU-W7DKE
    UnitCS-W7DKECU-W7DKE
    Cooling CapacitykW (kcal/h)2.30 (1,980)
    BTU/h7,840
    Heating CapacitykW (kcal/h)2.45 (2,110)
    BTU/h8,350
    Moisture Removall/h (Pint/h)1.5 (3.2)
    PhaseøSingle
    Power SourceVoltageV230
    CycleHz50
    Airflow MethodOUTLET
    INTAKE
    SIDEVIEWTOP VIEW
    Air VolumeLom3/min (cfm)Cooling; 5.8 (203)—
    Heating; 6.3 (220)
    Mem3/min (cfm)Cooling; 6.9 (245)—
    Heating; 7.0 (250)
    Him3/min (cfm)Cooling; 7.9 (280)Cooling; 26.0 (920)
    Heating; 9.1 (320)
    SHim3/min (cfm)Cooling; 9.0 (318)—
    Heating; 9.0 (318)
    Noise LeveldB (A)Cooling; High 34, Low 26Cooling; High 46
    Heating; High 36, Low 26Heating; High 48
    Power level dBCooling; High 47Cooling; High 61
    Heating; High 49Heating; High 63
    Electrical DataInputWCooling; 710
    Heating; 675
    Running CurrentACooling; 3.2
    Heating; 3.0
    EERW/W (BTU/hW)Cooling; 3.24 (11.0)
    COPW/W (BTU/hW)Heating; 3.63 (12.4)
    Starting CurrentA12.0
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 3/8”
    L ; Half Union 1/4”G ; 3-way valve 3/8”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 3/8”
    L ; (liquid side) 1/4”G ; (gas side) 3/8”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    7
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							UnitCS-W7DKECU-W7DKE
    Power Cord Length
    Number of core-wirem1.9
    3 (1.5 mm2)—
    —
    DimensionsHeightinch (mm)11 - 1/32 (280)20 - 3/32 (510)
    Widthinch (mm)31 - 15/32 (799)25 - 19/32 (650)
    Depthinch (mm)7 - 7/32 (183)9 - 1/16 (230)
    Net Weightlb (kg)20 (9.0)57 (26)
    CompressorDescription—Rotary (1 cylinder)
    rolling pistontype
    MotorType—Induction (2-poles)
    RatedOutputW—600
    Air CirculationDescriptionCross-flow FanPropeller Fan
    MaterialASG20k1PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW4768
    RatedOutputW1530
    Fan SpeedLowrpmCooling; 780—
    Heating; 840
    MediumrpmCooling; 940—
    Heating; 940
    HighrpmCooling; 1,070815
    Heating; 1,220
    SuperHighrpmCooling; 1,220—
    Heating; 1,220
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinCorrugate Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×152×23
    FPI2117
    Size (W × H × L)mm610 × 315 × 25.4597.7
    585.7× 483 × 36.4
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—FV50S (300)
    Refrigerant (R-410A)g (oz)—910 (32.1)
    ThermostatElectronic Control—
    Protection Device—Overload Protector
    Capillary TubeLengthmm—Cooling; 955, Heating; 415
    Flow Ratel/min—Cooling; 6.5, Heating; 9.6
    Inner Diametermm—Cooling; 1.3, Heating; 1.3
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—20 µF, 400VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 440VAC2.0 µF, 440VAC
     • 
    Specifica tions are subject to change without notice for further improvement.
    8
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							3.2. CS-W9DKE CU-W9DKE
    UnitCS-W9DKECU-W9DKE
    Cooling CapacitykW (kcal/h)2.75 (2,370)
    BTU/h9,380
    Heating CapacitykW (kcal/h)3.05 (2,620)
    BTU/h10,400
    Moisture Removall/h (Pint/h)1.6 (3.4)
    PhaseøSingle
    Power SourceVoltageV230
    CycleHz50
    Airflow MethodOUTLET
    INTAKE
    SIDEVIEWTOP VIEW
    Air VolumeLom3/min (cfm)Cooling; 5.8 (204)—
    Heating; 6.2 (220)
    Mem3/min (cfm)Cooling; 7.3 (257)—
    Heating; 7.3 (257)
    Him3/min (cfm)Cooling; 8.6 (300)Cooling; 26.0 (920)
    Heating; 9.7 (340)
    SHim3/min (cfm)Cooling; 9.7 (343)—
    Heating; 9.7 (343)
    dB (A)Cooling; High 36, Low 26Cooling; High 48
    Heating; High 39, Low 26Heating; High 49
    Noise Level
    Power level (dB)Cooling; High 49Cooling; High 63
    Heating; High 52Heating; High 64
    Electrical DataInputWCooling; 855
    Heating; 845
    Running CurrentACooling; 3.8
    Heating; 3.8
    EERW/W (BTU/hW)Cooling; 3.22 (11.0)
    COPW/W (BTU/hW)Heating; 3.61 (12.3)
    Starting CurrentA17.2
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 3/8”
    L ; Half Union 1/4”G ; 3-way valve 3/8”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 3/8”
    L ; (liquid side) 1/4”G ; (gas side) 3/8”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power Cord Length
    Number of core-wirem1.9
    3 (1.5 mm2)—
    —
    9
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							UnitCS-W9DKECU-W9DKE
    DimensionsHeightinch (mm)11 - 1/32 (280)20 - 3/32 (510)
    Widthinch (mm)31 - 15/32 (799)25 - 19/32 (650)
    Depthinch (mm)7 - 7/32 (183)9 - 1/16 (230)
    Net Weightlb (kg)20 (9.0)64 (29)
    CompressorDescription—Rotary (1 cylinder)
    rolling pistontype
    MotorType—Induction (2-poles)
    RatedOutputW—700
    Air CirculationDescriptionCross-flow FanPropeller Fan
    MaterialASG20k1PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW4768
    RatedOutputW1530
    Fan SpeedLowrpmCooling; 780—
    Heating; 840
    MediumrpmCooling; 980—
    Heating; 980
    HighrpmCooling; 1,160815
    Heating; 1,310
    SuperHighrpmCooling; 1,310—
    Heating; 1,310
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinCorrugate Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×152×23
    FPI2117
    Size (W×H×L)mm610×315×25.4597.7
    585.7×483×36.4
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—FV50S (350)
    Refrigerant (R-410A)g (oz)—950 (33.5)
    ThermostatElectronic Control—
    Protection Device—Overload Protector
    Capillary TubeLengthmm—Cooling; 475, Heating; 330
    Flow Ratel/min—Cooling; 7.2, Heating; 10.7
    Inner Diametermm—Cooling; 1.2, Heating; 1.3
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—30 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 440VAC2.0 µF, 440VAC
     • 
    Specifica tions are subject to change without notice for further improvement.
    10
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    All Panasonic manuals Comments (0)