    							 Operation Details
    Auto, Heat, Cool, DryAuto, Heat, Cool, Dr y
    •  Enables you to enjoy the cooling 
    effect at your preferred setting 
    temperature.
    •  The range of temperature can be 
    selected from 16°C ~ 30°C.
    •  Enables you to set the desired 
    temperature at low fan speed which  
    provides you with the dehumidifying 
    surroundings.
    •  The range of temperature can be 
    selected from 16°C ~ 30°C.
    AUTO - Automatic Operation
    COOL - Cooling Operation
    DRY - Soft Dr y Operation
    HOW TO OPERATE
      Supersonic air purifying device (super alleru-buster) operates 
    automatically while the air conditioner is switched on.
      Powerful, Quiet and Ion operations could be activated in all 
    operation modes.
      Press
     
    OFF/ON
     button again to stop the operation.
    Troubleshooting
      The room has a peculiar odour.
    ➤  This may be a damp smell emitted by the wall, carpet, furniture or 
    clothing in the room.
      Air conditioner does not cool or heat effi ciently.
    ➤  Ensure the temperature has been set correctly.
    ➤  Ensure windows and doors have been closed properly.
    ➤  Ensure fi lters are cleaned or replaced when necessary.
    ➤  Ensure inlet and outlet vents of outdoor unit have not been obstructed.
      In heating operation Power indicator blinking, no 
    warm air discharge.➤  Defrost operation at outdoor unit, maximum 12 minutes.
      To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
    Hint
    •  The unit will automatically select the 
    operation mode according to the 
    room temperature.
    •  Once the operation mode is 
    selected, the unit will operate at the 
    standard setting temperature as 
    shown:
    Room
    temperatureOperation
    modeStandard 
    setting 
    temperature
    23°C & above Cool 25°C
    Below 23°C Dry 22°C
    Below 20°C Heat 21°C
    •  You may press  or  button 
    to change the standard setting 
    temperature to “HI” or “LO” as 
    shown:
    Operation mode HI LO
    Cool 27°C 23°C
    Dry 24°C 20°C
    Heat 23°C 19°C
    •  Enables you to enjoy the warming 
    effect at your preferred setting 
    temperature.
    •  The range of temperature can be 
    selected from 16°C ~ 30°C.
    HEAT - Heating Operation
    22
    Select the 
    desired 
    operation.
    33
    Set the
    temperature. Start the 
    operation.
    11
    AUTO
    COOLHEAT DRY
    41
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							 Operations Details
    •  To provide fresh air effect by 
    producing negative ions. •  To achieve setting temperature 
    quickly. It will operate for 15 minutes 
    and return to the previous setting.
    ION
    POWERFULPowerful, Powerful, Quiet, Quiet, Ion, Fan Speed, Ion, Fan Speed, 
    Air SwingAir Swing
    •  To provide you with the various fan 
    speed selections.
    •  There are 3 levels of fan speed in 
    addition to automatic fan speed.
    •  Automatic fan speed:
      The speed of the indoor fan is 
    automatically adjusted according to 
    the operation.
    FAN SPEED •  To provide a quiet environment.
    QUIET
    •  To ventilate air in the room.
    •  There are 5 selections in addition to 
    automatic vertical air fl ow direction.
    •  If automatic vertical airfl ow direction 
    has been set, the louver swings up 
    and down automatically.
    •  Please do not adjust the vertical 
    airfl ow direction louver manually.
    •  Horizontal airfl ow direction louver 
    could be adjusted manually.
    AIR SWING
      Ion operation could be activated independently.
      Powerful and Quiet operations could not be activated at the 
    same time.
      Powerful, Quiet and Ion operations could be cancelled by 
    pressing the respective button again.
    Troubleshooting
      ION indicator on the indoor unit is blinking.
    ➤  Press ION button twice. If the indicator is still blinking, please consult 
    the dealer.
      Indoor fan stops occasionally during Automatic Fan 
    Speed setting.
      Indoor fan stops occasionally during heating operation.➤  This is an advanced feature that helps to remove smell from the 
    surrounding area during operation.
    ➤  To avoids unintended cooling effect.
    HOW TO OPERATE
    Hints
      If you wish to have the cool air blowing directly on you, set the airfl ow direction downward but not for an excessive length of time, 
    as it may harm your health.
      Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating 
    operation than the desired temperature.
    Enables 
    powerful 
    operation.Enables ion 
    operation.IONIONPOWERFULPOWERFUL
    Select fan speed.
    FAN SPEED FAN SPEED
    Adjust the 
    vertical airfl ow 
    direction louver.
    AIR SWINGAIR SWING
    Enables quiet 
    operation.
    QUIETQUIET
    42
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							  Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format.  For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.
    Hint
    Troubleshooting
      TIMER indicator always on.
    ➤  Timer is activated and the setting will repeat itself daily.
      POWER indicator is blinking 30 minutes before ON 
    timer is activated.➤  The unit is determining the operation mode by sensing the room 
    temperature. This happens when it has been set to AUTO operation 
    mode.
    HOW TO OPERATE
    TimerTimer
     Operation Details
    •  Use the ON timer to turn on the air 
    conditioner at the desired time. This 
    will give you a cooling or warming 
    environment, e.g. when you return 
    from work or wake up.
    •  When the ON timer is set, operation 
    will start 15 minutes for COOL/DRY 
    or 30 minutes for AUTO/HEAT 
    before the actual set time.
    •  Use the OFF timer to stop the air 
    conditioner operation at the desired 
    time. This can save electricity while 
    you are going out or sleeping.
    •  The set timer will repeat daily once 
    it is set.
    •  If there is a power failure, you can 
    press SET button to restore the 
    previous setting once the power is 
    resumed.
    •  If the timer is cancelled, you can 
    restore the previous setting by 
    pressing SET button.
    TIMER
      Ensure the clock on the remote control has been set 
    correctly.
      You could use the ON and OFF timers at the same time.
      To cancel either the ON or OFF timer, press 
     or , 
    then press 
    .
    11
    Select ON or 
    OFF timer.
    22
    Set the 
    desired time.
    33
    Confi rm the 
    setting.
    CANCELCANCEL
    Cancel the 
    selected timer.
    43
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							CARE & CLEANING
    •  Wipe the unit gently with a soft, dry 
    cloth.
    •  It is recommended to clean the air 
    fi lters once every 2 weeks.
    •  Purchase the replacement fi lter if it 
    is damaged.
      Part no.: CWD001144
    INDOOR UNIT
    AIR FILTER
    •  It is recommended to clean the fi lter 
    every 6 months.
    •  Replace the fi lter every 3 years or 
    purchase the replacement fi lter if it 
    is damaged. 
      Part no.: CZ-SA13P
    SUPER ALLERU-BUSTER
      Clean the fi lter regularly as dirty fi lters will cause unpurifi ed air, low cooling or heating capacity, unpleasant smells and higher 
    energy consumption.
      The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an 
    authorized dealer to perform seasonal inspections in addition to regular cleaning.•  This inspection is recommended 
    before operating the air conditioner 
    at every season.
    •  Check if the remote control batteries 
    needed to be replaced.
    •  Ensure there is no obstruction at all 
    air intake and outlet vents.
    •  After the start of operation for 15 
    minutes, it is normal if the 
    temperature differences between 
    air intake and outlet vents at indoor 
    unit is:-
    Operation Temperature
    Cooling  
     8°C
    Heating    14°C •  Operate the unit for 2~3 hours using 
    ion operation to dry the internal parts.
    •  Turn off the power supply and unplug.
    •  Remove the remote control batteries.
    Switch off  the power supply Switch off  the power supply 
    before cleaningbefore cleaning
    Hints
     Washing Instructions•  Do not use benzene, thinner or 
    scouring powder.
    •  Use soaps or neutral household 
    detergent (
    ≃pH7) only.
    •  Do not use water with temperature 
    higher than 40°C.
     Pre-season Inspection  Preparation for extended 
    Non-operation
    •  It is recommended to clean the 
    ionizer every 6 months.
    IONIZERQ
    UIETPO
    WE
    RFULIONTIM
    ER POWE
    R
    Raise and Pull to remove. 
    Wash and dry.
    FRONT PANELFRONT PANEL
    Wipe gently.
    INDOOR UNITINDOOR UNIT
    Vacuum, wash and dry.
    AIR FILTERAIR FILTER
    SUPERSONIC AIR SUPERSONIC AIR 
    PURIFYING DEVICEPURIFYING DEVICE
    Clean with cotton 
    bud.
    IONIZERIONIZER
    Remove
    Remove
    Vacuum the super 
    alleru-buster fi lter.
    Vacuum, wash and 
    dry the frame.
    Remove
    44
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							10 Installation Instructions
    Required tools for Installation Works
    1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter
    2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench
    18 N.m (1.8 kgf.m)
    42 N.m (4.2 kgf.m)
    55 N.m (5.5 kgf.m)
    3.Electric drill, hole core drill
    (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump
    4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifold
    10.1. Safety Precautions
     • 
    Read the followin g“SAFET Y PRECA UTIONS”carefully before installation.
     • 
    Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
    for the model to be installed.
     • 
    The caution items stated here must be followed because these important contents are related to safety. The meaning of each
    indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
    seriousness is classified by the followin g indications.
    WARNINGThis indication shows the possibility of causing death or serious injury.
    CAUTIONThis indication shows the possibility of causing injury or damage to properties only.
    The items to be followed are classified by the symbols:
    Symbol with background white denotes item that is PROHIBITE D from doing.
     • 
    Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
    maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
    WARNING
    1.Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
    2.Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
    3.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
    electrical shock.
    4.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
    done, the set will drop and cause injury.
    5.For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
    outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
    6.Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
    external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
    7.Wire routing must beproperly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
    cause heat-up at connection point of terminal, fire or electrical shock.
    8.When carrying outpiping connection, take care not to let air substances other than the specified refrigerant go into
    refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion
    and injury.
    9.Whenconnecting the piping, do not allow air or any substances other than the specified refrigerant (R410A) to enter the
    refrigeration cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and
    possibly result in explosion and injury.
    10. • 
    W hen connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause
    abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only
    R410A materials.
     • 
    Thickness of copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8
    mm.
     • 
    It is desirable that the amount of residual oil is less than 40 mg/10 m.
    11.Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
    other electrical appliances. Otherwise, it will cause fire or electrical shock.
    45
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							CAUTION
    1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
    2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
    surrounding of the unit, it may cause fire.
    3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
    furniture.
    ATTENTION
    1.Selection of the installation location.
    Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
    2.Power supply connection to the room air conditioner.
    Connect the power supply cord of the room air conditioner to the mains using one of the following method.
    Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
    In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
     1. Power supply connection to the receptacle using a power plug.
    Use an approved 10A power plug with earth pin for the connection to the socket..
     2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent
    connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
    3.Do not release refrigerant.
    Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
    liquid refrigerant, it may cause frostbite.
    4.Installation work.
    It may need two people to carry out the installation work.
    5.Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
    46
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							Attached access ories
    Applica ble piping kit
    CZ-3F5, 7BP (V7DK, V9DK,W7DK, W9DK)
    CZ-4F5, 7, 10BP (V12DK , W12DK)
    Select the best location
    INDOOR UNIT
     • There should not be any heat source or steam near
    the unit.
     • There should not be any obstacles blocking the air
    circulation.
     • A place where air circulation in the room is good.
     • A place where drainage can be easily done.
     • A place where noise prevention is taken into
    conside ration.
     • Do not install the unit near the door way.
     • Ensure the spaces indicate d by arrows from the wall,
    ceiling, fence or other obstacles.
     • Recommended installation height for indoor unit
    shall be at least 2.3 m.
    OUTDOOR UNIT
     • If an awning is built over the unit to prevent direct
    sunlight or rain, be careful that heat radiation from
    the conden ser is not obstructed.
     • There should not be any animal or plant which could
    be affected by hot air discharged.
     • Keep the spaces indicate d by arrows from wall,
    ceiling, fence or other obstacles.
     • Do not place any obstacles which may cause a short
    circuit of the discharged air.
     • If piping length is over the rated length, addition al
    refrigerant should be added as shown in the table.
    Indoor/outdoor Unit Installation Diagram
     • This illustration is for explana tion purposes only.
    The indoor unit will actually face a differen t way.
    47
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							10.2.1. SELECT THE BEST LOCATION
    (Refer to “Select the best location”
    section)
    10.2.2. HOW TO FIX INSTALLATION
    PLATE
    The mounting wall is strong and solid enough to prevent itfrom
    the vibration.
    The centre of installation plate should be at more than 450 mm
    at right and left of the wall.
    The distance from installation plate edge toceiling should more
    than 67 mm.
    From installation plate left edge to unit’s left side is 74 mm.
    From installation plate right edge to unit’s right is 94 mm.
    :
    :
    :For left side piping, piping connection for liquid should be
    about 15 mm from this line.
    For left side piping, piping connection for gas should be
    about 45 mm from this line.
    For left side piping, piping connection cable should be
    about 800 mm from this line
     1. Mount the installation plate on the wall with 5 screws or
    more.
    (If mounting the unit on the concrete wall conside r using
    anchor bolts.)
     • Alwaysmount the installation plate horizontally by
    aligning the marking-off line with the thread and using a
    level gauge.
     2. Drill the piping plate hole withø70 mm hole-core drill.
     • Line according to the arrows marked on the lower left
    and right side of the installation plate. The meeting point
    of the extended line is the centre of the hole. Anothe r
    method is by putting measuring tape at position as
    shown in the diagram above. The hole centre is
    obtaine d by measuring the distance namely 150 mm
    and 125 mm for left and right hole respectively.
     • Drill the piping hole at either the right or the left and the
    hole should be slightly slanted to the outdoor side.
    10.2.3. TO DRILL A HOLE IN THEWALL
    AND INSTALL A SLEEVE OF
    PIPING
     1. Insert the piping sleeve to the hole.
     2. Fix the bushing to the sleeve.
     3. Cut the sleeve until it extrudes about 15 mm from the wall.
    CautionWhen thewall is hollow, please be sure to use the
    sleeve for tube ass’y to prevent dangers caused by
    mice biting the connecting cable.
     4. Finish by sealing the sleeve with putty or caulking
    compound at the final stage.
    10.2.4. INDOOR UNIT INSTALLATION
     1. For the right rear piping
     2. For the right and right bottom piping
    10.2. Indoor Unit
    48
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							 3. For the embedded piping
    (This can be used for left rear piping & left bottom piping also.)
    49
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						
    							10.2.5. CONNECT THECABLE TO THE
    INDOOR UNIT
     1. The inside and outside connecting cable can be connected
    without removing the front grille.
     2. Connec ting cable between indoor unit and outdoor unit
    shall be approved polychl oroprene sheathed 3 (V7DK,
    V9DK, V12DK ) or 5(W7DK, W9DK, W12DK)×1.5 mm
    2
    flexible cord, type designa tion 245 IEC 57 or heavier cord.
     • Ensure the color of wires of outdoor unit and the
    terminal Nos. are the same to the indoor’s respectively.
     • Earth lead wire shall be longer than the other lead wires
    as shown in the figure for the electrical safety in case of
    the slipping out of the cord from the anchorage.
     • Secure the cable onto the control board with the holder
    (clamper).
    50
    CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE 
    						