Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual
Here you can view all the pages of manual Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 31
Troubleshooting No problemOK? Operation delayed for 3 minutes after successful restartSelf protection procedure It sounds like water flowing...Caused by refrigerant flow inside Fog seems to emerge from the indoor unitCondensation effect due to cooling With setting «FAN AUTO» indoor fan stops sometimesSmell eliminating procedure No OperationCircuit breaker tripped? Power plug OK? TIMER used correctly? Noise too loudInstallation work slanted? Front grille / panel closed properly? Cooling efficiency...
Page 32
Safety precautions EMERGENCY! Immediately isolate from the mains supply (e.g. in case of burnt smell) Use only for... Cooling DehumidifyingAir circulation NEVER use this unit for purposes other than mentioned in these Operating Instructions, especially do not use this unit for preservation etc. Installation NOT in potentially explosive atmosphere Engage dealer / specialist Mains connection Engage dealer / specialist for mains connection including... Used connectors / breakers easy reachable! NEVER...
Page 33
Do NOT repair yourself Do NOT wash! Defect / suspicion of defect? –> Do NOT use! – attend defects due to long time usage Waste disposal! Operational Condition 11 23 16 32 11 16 16 43 Defects! Engage dealer / specialist Cleaning! OFF / and unplug (connector or breaker) Packaging recyclable Uninstall and disposal of the unit ONLY by dealer / specialists 33 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 34
10 Installation Instructions Required tools for Installation Works 1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter 2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3.Electric drill, hole core drill (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump 4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifold 10.1. Safety Precautions • Read the followin g“SAFET Y PRECA UTIONS”carefully before installation. • Electrical work...
Page 35
1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 1.Selection of the installation location. Select a installation location which is rigid and strong enough to...
Page 36
Applica ble piping kit CZ-3F5, 7AEN (PC9CK, SC9CK , E719K , E919K ) CZ-4F5, 7, 10AN (PC12CK, SC12C K, E1219K ) SELEC T THE BEST LOCATION INDOOR UNIT • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation. • A place where air circulation in the room is good. • A place where drainage can be easily done. • A place where noise prevention is taken into conside ration. • Do not install the unit near the door way. • Ensure the spaces...
Page 37
10.2.1. SELECT THE BEST LOCATION (Refer to“Select the best location” section) 10.2.2. HOW TO FIX INSTALLATION PLATE The mounting wall is strong and solid enough to prevent itfrom the vibration. The centre of installation plate should be at more than 450 mm at right and left of the wall. The distance from installation plate edge toceiling should more than 67 mm. From installation plate left edge to unit’s left side is 47 mm. From installation plate right edge to unit’s right is 73 mm. : : :For left side...
Page 38
3. For the embedded piping (This can be used for left rear piping & left bottom piping also.) 38 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 39
1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connec ting cable between indoor unit and outdoor unit shall be approved polychl oroprene sheathed 3 (PC9CK, PC12C K, SC9CK , SC12C K, E719K , E919K , E1219K )×1.5 mm 2flexible cord, type designa tion 245 IEC 57 or heavier cord. • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • Earth lead wire shall be longer than the other lead wires as shown...
Page 40
AUTO SWITCH OPERATION 1. AUTO OPERA TION MODE The Auto operation will be activated immediately once the Auto Switch is pressed. 2. TEST RUN OPERA TION (FOR PUMPDOWN/SERV ICING PURPOSE) The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to below 10 sec.. A“pep”sound will occur at the fifth sec., in order to identify the starting of Test Run operation 3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF The ON/OFF of Remote Controller receiving sound can be...