Troubleshooting No problemOK? Operation delayed for 3 minutes after successful restartSelf protection procedure It sounds like water flowing...Caused by refrigerant flow inside Fog seems to emerge from the indoor unitCondensation effect due to cooling With setting «FAN AUTO» indoor fan stops sometimesSmell eliminating procedure No OperationCircuit breaker tripped? Power plug OK? TIMER used correctly? Noise too loudInstallation work slanted? Front grille / panel closed properly? Cooling efficiency lowTemperature set correctly? Windows / doors closed? Outdoor unit obstructed? Filters cleaned / replaced? Intake / outlet ventilators obstructed? Remote control / display doesn’t workBatteries empty? Batteries correctly inserted (+) and (–)? See page 27 TURN OFF - UNPLUG - CALL authorized distributor IN CASE OF... •Abnormal noise during operation •Water / foreign materials got into Remote Control •Water leak from Indoor Unit •Switches / buttons do not operate properly •Circuit breaker switches off frequently •Power plug / cord warm up unusually Manufactured by: MATSUSHITA INDUSTRIAL CORP. SDN. BHD. Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site Selangor, Malaysia MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD. Web site: http://www.panasonic.co.jp/global/ 31 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Safety precautions EMERGENCY! Immediately isolate from the mains supply (e.g. in case of burnt smell) Use only for... Cooling DehumidifyingAir circulation NEVER use this unit for purposes other than mentioned in these Operating Instructions, especially do not use this unit for preservation etc. Installation NOT in potentially explosive atmosphere Engage dealer / specialist Mains connection Engage dealer / specialist for mains connection including... Used connectors / breakers easy reachable! NEVER shared Before operating, read the safety precautions thoroughly Operation! Install, remove or reinstall never yourself Connect drain hose properly Connect protective earth! Plug in properlyThe appliance is not intended for use by young children or infirm person without supervision. Young children should be supervised to ensure that they do not play with the appliance. Defective cables / connectors are only to be repaired by authorised dealers / specialists to avoid risk Do not pull the cord to disconnect NO fingers or objects into the unit! –> especially dangerous for children! Place nothing on the unit –> covered openings may cause overheating / fire Unused for a long time? –> OFF / unplug Ventilate the room periodically Do NOT operate with wet hands Do NOT stay long within the cold airstream NEVER modify / damage mains cables or connectors NEVER for on / off 32 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Do NOT repair yourself Do NOT wash! Defect / suspicion of defect? –> Do NOT use! – attend defects due to long time usage Waste disposal! Operational Condition 11 23 16 32 11 16 16 43 Defects! Engage dealer / specialist Cleaning! OFF / and unplug (connector or breaker) Packaging recyclable Uninstall and disposal of the unit ONLY by dealer / specialists 33 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
10 Installation Instructions Required tools for Installation Works 1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter 2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3.Electric drill, hole core drill (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump 4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifold 10.1. Safety Precautions • Read the followin g“SAFET Y PRECA UTIONS”carefully before installation. • Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed. • The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the followin g indications. This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties only. The items to be followed are classified by the symbols: Symbol with background white denotes item that is PROHIBITE D from doing. • Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 1.Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2.Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5.For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6.Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7.Wire routing must beproperly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8.When carrying outpiping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury. 9.Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock. 10.Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock. 34 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 1.Selection of the installation location. Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. 2.Power supply connection to the room air conditioner. Connect the power supply cord of the room air conditioner to the mains using one of the following method. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. 1. Power supply connection to the receptacle using a power plug. Use an approved 15A/16A power plug with earth pin for the connection to the socket. 2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3 mm contact gap. 3.Do not release refrigerant. Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite. 4.Installation work. It may need two people to carry out the installation work. 5.Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 35 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Applica ble piping kit CZ-3F5, 7AEN (PC9CK, SC9CK , E719K , E919K ) CZ-4F5, 7, 10AN (PC12CK, SC12C K, E1219K ) SELEC T THE BEST LOCATION INDOOR UNIT • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation. • A place where air circulation in the room is good. • A place where drainage can be easily done. • A place where noise prevention is taken into conside ration. • Do not install the unit near the door way. • Ensure the spaces indicate d by arrows from the wall, ceiling, fence or other obstacles. • Recommended installation height for indoor unit shall be at least 2.3 m. OUTDOOR UNIT • If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the conden ser is not obstructed. • There should not be any animal or plant which could be affected by hot air discharged. • Keep the spaces indicate d by arrows from wall, ceiling, fence or other obstacles. • Do not place any obstacles which may cause a short circuit of the discharged air. • If piping length is over the common length, addition al refrigerant should be added as shown in the table. REMOTE CONTROL • Do not install at places where there is direct sunlight or near any heat sourc. Indoor/Outdoor Unit Installation Diagram • This illustration is for explana tion purposes only. The indoor unit will actually face a differen t way. Attached access ories 36 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
10.2.1. SELECT THE BEST LOCATION (Refer to“Select the best location” section) 10.2.2. HOW TO FIX INSTALLATION PLATE The mounting wall is strong and solid enough to prevent itfrom the vibration. The centre of installation plate should be at more than 450 mm at right and left of the wall. The distance from installation plate edge toceiling should more than 67 mm. From installation plate left edge to unit’s left side is 47 mm. From installation plate right edge to unit’s right is 73 mm. : : :For left side piping, piping connection for liquid should be about 14 mm from this line. For left side piping, piping connection for gas should be about 56 mm from this line. For left side piping, piping connecting cable should be about 785 mm from this line. 1. Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the concrete wall conside r using anchor bolts.) • Alwaysmount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge. 2. Drill the piping plate hole withø70 mm hole-core drill. • Line according to the arrows marked on the lower left and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Anothe r method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtaine d by measuring the distance namely 150 mm and 125 mm for left and right hole respectively. • Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side. 10.2.3. TO DRILL A HOLE IN THEWALL AND INSTALL A SLEEVE OF PIPING 1. Insert the piping sleeve to the hole. 2. Fix the bushing to the sleeve. 3. Cut the sleeve until it extrudes about 15 mm from the wall. CautionWhen thewall is hollow, please be sure to use the sleeve for tube ass’y to prevent dangers caused by mice biting the connecting cable. 4. Finish by sealing the sleeve with putty or caulking compound at the final stage. 10.2.4. INDOOR UNIT INSTALLATION 1. For the right rear piping 2. For the right and right bottom piping 10.2. INDOOR UNIT 37 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
3. For the embedded piping (This can be used for left rear piping & left bottom piping also.) 38 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connec ting cable between indoor unit and outdoor unit shall be approved polychl oroprene sheathed 3 (PC9CK, PC12C K, SC9CK , SC12C K, E719K , E919K , E1219K )×1.5 mm 2flexible cord, type designa tion 245 IEC 57 or heavier cord. • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • Earth lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety in case of the slipping out of the cord from the anchorage. • Secure the cable onto the control board with the holder (clamper). HOW TO TAKE OUT FRONT GRILLE Whenreinstalling the front grille, first set the vertical airflow direction louver to the horizontal position and then carry out above steps 2 - 3 in the reverse order. 10.2.5. CONNECT THECABLE TO THEINDOOR UNIT Please follow the steps below to take out front grille if necessary such as when servicing. 1. Set the vertical airflow direction louver to the horizontal position . 2. Slide down the two caps on the front grille as shown in the illustration below, and then remove the two mounting screws. 3. Pull the lower section of the front grille towards you to remove the front grille. 39 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
AUTO SWITCH OPERATION 1. AUTO OPERA TION MODE The Auto operation will be activated immediately once the Auto Switch is pressed. 2. TEST RUN OPERA TION (FOR PUMPDOWN/SERV ICING PURPOSE) The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to below 10 sec.. A“pep”sound will occur at the fifth sec., in order to identify the starting of Test Run operation 3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF The ON/OFF of Remote Controller receiving sound can be change over by pressing the“AUTO”Switch continuously for 10 sec. and above. A“pep”,“pep”sound will occur at the tenth sec., in order to indicate the“ON/OFF”change over of remote control receiving sound. HOW TO INSTALL WIRED REMOTE CONTROL • After selecting the best location , start installation according to Indoor/Outdoo r Unit Installation Diagram. 1. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut. (ø10 mm). 2. When installin g at roof, please conside r strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails. (PC9CK, PC12C K, E719K , E919K , E1219K ONLY) The below operations will be performed by pressing the“AUTO”switch. (SC9CK, SC12C K ONLY) 1. Select the best location . (Refer to Select the Best Laction Section ) 2. Install the wired remote control holder to the wall by fixing it with two screws (Refer toDiagram A). 3. Mount the wired remote control. (Refer to Diagram B). Note: Install the remote control less than 1.5m from the unit and within user´s reach. It is reccommended to use the attached cord holders for good finish when the cord is fixed on a wall or a pillar. 10.3. OUTDOOR UNIT 10.3.1. SELECT THE BEST LOCATION (Refer to“Select the best location”section) 10.3.2. INSTALL THE OUTDOOR UNIT 40 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K