    							Troubleshooting
    No problemOK?
    Operation delayed for 3 minutes after successful restartSelf protection procedure
    It sounds like water flowing...Caused by refrigerant flow inside
    Fog seems to emerge from the indoor unitCondensation effect due to cooling
    With setting «FAN AUTO» indoor fan stops sometimesSmell eliminating procedure
    No OperationCircuit breaker tripped? Power plug OK? TIMER used correctly?
    Noise too loudInstallation work slanted? Front grille / panel closed properly?
    Cooling efficiency lowTemperature set correctly? Windows / doors closed? Outdoor unit obstructed?
    Filters cleaned / replaced? Intake / outlet ventilators obstructed?
    Remote control / display doesn’t workBatteries empty? Batteries correctly inserted (+) and (–)? See page 27
    TURN OFF - UNPLUG - CALL authorized distributor
    IN CASE OF...
    •Abnormal noise during operation
    •Water / foreign materials got into Remote Control
    •Water leak from Indoor Unit
    •Switches / buttons do not operate properly
    •Circuit breaker switches off frequently
    •Power plug / cord warm up unusually
    Manufactured by:
    MATSUSHITA INDUSTRIAL CORP. SDN. BHD.
    Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam
    Industrial Site Selangor, Malaysia
    MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD.
    Web site: http://www.panasonic.co.jp/global/
    31
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							Safety precautions
    EMERGENCY!
    Immediately isolate from the mains supply (e.g. in case of burnt smell)
    Use only for...
    Cooling DehumidifyingAir circulation
    NEVER use this unit for purposes other than mentioned in these Operating Instructions, especially do not use
    this unit for preservation etc.
    Installation
    NOT in potentially explosive atmosphere
    Engage dealer / specialist
    Mains connection
    Engage dealer / specialist for mains connection including...
    Used connectors / breakers easy reachable!
    NEVER shared
    Before operating, read the safety precautions thoroughly
    Operation!
    Install, remove or reinstall never yourself
    Connect drain hose properly
    Connect protective earth!
    Plug in properlyThe appliance is not intended for use by young children or infirm person without supervision. Young
    children should be supervised to ensure that they do not play with the appliance.
    Defective cables / connectors are only to be repaired by authorised dealers / specialists to avoid risk
    Do not pull the cord to disconnect
    NO fingers or objects into the unit! –>
     especially dangerous for children!
    Place nothing on the unit –>
     covered openings may cause overheating / fire
    Unused for a long time? –>
     OFF / unplug
    Ventilate the room periodically Do NOT operate with wet hands
    Do NOT stay long within the cold airstream
    NEVER modify / damage mains cables or connectors
    NEVER for on / off
    32
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							Do NOT repair yourself
    Do NOT wash!
    Defect / suspicion of defect? –>
     Do NOT use! – attend defects due to long time usage
    Waste disposal!
    Operational Condition
    11 23 16 32
    11 16 16 43
    Defects!
    Engage dealer / specialist
    Cleaning!
    OFF / and unplug (connector or breaker)
    Packaging recyclable Uninstall and disposal of the unit ONLY by dealer / specialists
    33
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							10 Installation Instructions
    Required tools for Installation Works
    1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter
    2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench
    18 N.m (1.8 kgf.m)
    42 N.m (4.2 kgf.m)
    55 N.m (5.5 kgf.m)
    3.Electric drill, hole core drill
    (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump
    4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifold
    10.1. Safety Precautions
     • 
    Read the followin g“SAFET Y PRECA UTIONS”carefully before installation.
     • 
    Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
    for the model to be installed.
     • 
    The caution items stated here must be followed because these important contents are related to safety. The meaning of each
    indication used is as below.
    Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the
    followin g indications.
    This indication shows the possibility of causing death or serious injury.
    This indication shows the possibility of causing injury or damage to properties only.
    The items to be followed are classified by the symbols:
    Symbol with background white denotes item that is PROHIBITE D from doing.
     • 
    Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
    maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
    1.Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
    2.Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
    3.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
    electrical shock.
    4.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
    done, the set will drop and cause injury.
    5.For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
    outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
    6.Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
    external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
    7.Wire routing must beproperly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
    cause heat-up at connection point of terminal, fire or electrical shock.
    8.When carrying outpiping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.
    Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
    9.Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock.
    10.Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
    other electrical appliances. Otherwise, it will cause fire or electrical shock.
    34
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
    2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
    surrounding of the unit, it may cause fire.
    3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
    furniture.
    1.Selection of the installation location.
    Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
    2.Power supply connection to the room air conditioner.
    Connect the power supply cord of the room air conditioner to the mains using one of the following method.
    Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
    In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
     1. Power supply connection to the receptacle using a power plug.
    Use an approved 15A/16A power plug with earth pin for the connection to the socket.
     2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent
    connection. It must be a double pole switch with a minimum 3 mm contact gap.
    3.Do not release refrigerant.
    Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
    liquid refrigerant, it may cause frostbite.
    4.Installation work.
    It may need two people to carry out the installation work.
    5.Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
    35
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							Applica ble piping kit
    CZ-3F5, 7AEN (PC9CK, SC9CK , E719K , E919K )
    CZ-4F5, 7, 10AN (PC12CK, SC12C K, E1219K )
    SELEC T THE BEST LOCATION
    INDOOR UNIT
     • There should not be any heat source or steam near the
    unit.
     • There should not be any obstacles blocking the air
    circulation.
     • A place where air circulation in the room is good.
     • A place where drainage can be easily done.
     • A place where noise prevention is taken into
    conside ration.
     • Do not install the unit near the door way.
     • Ensure the spaces indicate d by arrows from the wall,
    ceiling, fence or other obstacles.
     • Recommended installation height for indoor unit shall be
    at least 2.3 m.
    OUTDOOR UNIT
     • If an awning is built over the unit to prevent direct
    sunlight or rain, be careful that heat radiation from the
    conden ser is not obstructed.
     • There should not be any animal or plant which could be
    affected by hot air discharged.
     • Keep the spaces indicate d by arrows from wall, ceiling,
    fence or other obstacles.
     • Do not place any obstacles which may cause a short
    circuit of the discharged air.
     • If piping length is over the common length, addition al
    refrigerant should be added as shown in the table.
    REMOTE CONTROL
     • Do not install at places where there is direct sunlight or
    near any heat sourc.
    Indoor/Outdoor Unit Installation Diagram
     • This illustration is for explana tion purposes only.
    The indoor unit will actually face a differen t way. Attached access ories
    36
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							10.2.1. SELECT THE BEST LOCATION
    (Refer to“Select the best location”
    section)
    10.2.2. HOW TO FIX INSTALLATION
    PLATE
    The mounting wall is strong and solid enough to prevent itfrom
    the vibration.
    The centre of installation plate should be at more than 450 mm
    at right and left of the wall.
    The distance from installation plate edge toceiling should more
    than 67 mm.
    From installation plate left edge to unit’s left side is 47 mm.
    From installation plate right edge to unit’s right is 73 mm.
    :
    :
    :For left side piping, piping connection for liquid should be
    about 14 mm from this line.
    For left side piping, piping connection for gas should be
    about 56 mm from this line.
    For left side piping, piping connecting cable should be
    about 785 mm from this line.
     1. Mount the installation plate on the wall with 5 screws or
    more.
    (If mounting the unit on the concrete wall conside r using
    anchor bolts.)
     • Alwaysmount the installation plate horizontally by
    aligning the marking-off line with the thread and using a
    level gauge.
     2. Drill the piping plate hole withø70 mm hole-core drill.
     • Line according to the arrows marked on the lower left
    and right side of the installation plate. The meeting point
    of the extended line is the centre of the hole. Anothe r
    method is by putting measuring tape at position as
    shown in the diagram above. The hole centre is
    obtaine d by measuring the distance namely 150 mm
    and 125 mm for left and right hole respectively.
     • Drill the piping hole at either the right or the left and the
    hole should be slightly slanted to the outdoor side.
    10.2.3. TO DRILL A HOLE IN THEWALL
    AND INSTALL A SLEEVE OF
    PIPING
     1. Insert the piping sleeve to the hole.
     2. Fix the bushing to the sleeve.
     3. Cut the sleeve until it extrudes about 15 mm from the wall.
    CautionWhen thewall is hollow, please be sure to use the
    sleeve for tube ass’y to prevent dangers caused by
    mice biting the connecting cable.
     4. Finish by sealing the sleeve with putty or caulking
    compound at the final stage.
    10.2.4. INDOOR UNIT INSTALLATION
     1. For the right rear piping
     2. For the right and right bottom piping
    10.2. INDOOR UNIT
    37
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							 3. For the embedded piping
    (This can be used for left rear piping & left bottom piping also.)
    38
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							 1. The inside and outside connecting cable can be connected
    without removing the front grille.
     2. Connec ting cable between indoor unit and outdoor unit
    shall be approved polychl oroprene sheathed 3 (PC9CK,
    PC12C K, SC9CK , SC12C K, E719K , E919K , E1219K )×1.5
    mm
    2flexible cord, type designa tion 245 IEC 57 or heavier
    cord.
     • Ensure the color of wires of outdoor unit and the
    terminal Nos. are the same to the indoor’s respectively.
     • Earth lead wire shall be longer than the other lead wires
    as shown in the figure for the electrical safety in case of
    the slipping out of the cord from the anchorage.
     • Secure the cable onto the control board with the holder
    (clamper).
    HOW TO TAKE OUT FRONT GRILLE
    Whenreinstalling the front grille, first set the vertical
    airflow direction louver to the horizontal position and
    then carry out above steps 2 - 3 in the reverse order.
    10.2.5. CONNECT THECABLE TO THEINDOOR UNIT
    Please follow the steps below to take out front grille if necessary such as when servicing.
     1. Set the vertical airflow direction louver to the horizontal position .
     2. Slide down the two caps on the front grille as shown in the illustration below, and then remove the two mounting screws.
     3. Pull the lower section of the front grille towards you to remove the front grille.
    39
    CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K 
    						
    							AUTO SWITCH OPERATION
     1. AUTO OPERA TION MODE
    The Auto operation will be activated immediately once the
    Auto Switch is pressed.
     2. TEST RUN OPERA TION (FOR PUMPDOWN/SERV ICING
    PURPOSE)
    The Test Run operation will be activated if the Auto Switch
    is pressed continuously for more than 5 sec. to below 10
    sec.. A“pep”sound will occur at the fifth sec., in order to
    identify the starting of Test Run operation
     3. REMOTE CONTROLLER RECEIVING SOUND ON/OFF
    The ON/OFF of Remote Controller receiving sound can be
    change over by pressing the“AUTO”Switch continuously
    for 10 sec. and above. A“pep”,“pep”sound will occur at the
    tenth sec., in order to indicate the“ON/OFF”change over of
    remote control receiving sound.
    HOW TO INSTALL WIRED REMOTE CONTROL
     • After selecting the best location , start installation according
    to Indoor/Outdoo r Unit Installation Diagram.
     1. Fix the unit on concrete or rigid frame firmly and horizontally
    by bolt nut. (ø10 mm).
     2. When installin g at roof, please conside r strong wind and
    earthquake. Please fasten the installation stand firmly with
    bolt or nails.
    (PC9CK, PC12C K, E719K , E919K , E1219K ONLY)
    The below operations will be performed by pressing the“AUTO”switch.
    (SC9CK, SC12C K ONLY)
     1. Select the best location .
    (Refer to Select the Best Laction Section )
     2. Install the wired remote control holder to the wall by fixing it with two screws (Refer toDiagram A).
     3. Mount the wired remote control. (Refer to Diagram B).
    Note: Install the remote control less than 1.5m from the unit and within user´s reach. It is reccommended to use the
    attached cord holders for good finish when the cord is fixed on a wall or a pillar.
    10.3. OUTDOOR UNIT
    10.3.1. SELECT THE BEST LOCATION
    (Refer to“Select the best location”section)
    10.3.2. INSTALL THE OUTDOOR UNIT
    40