Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual
Here you can view all the pages of manual Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
1 Features 2 2 Functions 3 3 Product Specifications 6 4 Dimensions 12 5 Refrigeration Cycle Diagram 14 6 Block Diagram 15 7 Wiring Diagram 16 8 Operation Details 17 9 Operating Instructions 26 10 Installation Instructions 34 © 2003 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-E719K CU-E719K CS-E919K CU-E919K CS-E1219K CU-E1219K 11 2-way, 3-way Valve 44 12 Servicing Information 51 13...
Page 2
• High Efficiency • Compact Design • Comfort Environment − Air filter with function to reduce dust and smoke − W ider range of horizontal discharge air • Auto Restart − Random auto restart after power failure for safety restart operation • Removable and Washa ble Front Panel • Remote Control Self-illuminating Button • Quality Improvement − Gas leakage protection − Prevent compressor reverse cycle − 2-stage OLP to protect compressor − Noise prevention during soft dry operation. • Operation...
Page 3
2 Functions Remote Control Operation OFF / ONOFF / ON IRoom Temperature SettingTEMP. Operation Mode Selection •AUTOAutomatic Operation Mode • COOLCooling Operation Mode • DRYSoft Dry Operation Mode • FANAir Circulation Mode MODE Indoor Fan Speed SelectionFAN SPEED •Low Fan Speed • Medium Fan Speed • High Fan Speed • AUTOAutomatic Fan Speed Vertical Airflow Direction ControlAIR SWING •AUTOAutomatic Vertical Airflow Direction Control • MANUALVertical Airflow Direction Manual Control (5 stages of...
Page 4
Indoor Unit Random Auto Restart Control •Operation is restarted randomly after power failure at previous setting mode. Anti-Freezing Control •Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry) Quiet Operation •To provide extra quiet operation. Indoor Fan Speed Control •High, Medium and Low. •Automatic Fan Speed Mode –Cooling : Fan rotates at Hi, Me and SLo speed. Deodorizing control is available. –Soft Dry: Fan rotates at Lo- speed. Deodorizing control is available. •Automatic air...
Page 5
Outdoor Unit •To protect compressor from reverse rotation when there is a instantaneous power failure. 60 Secs. Forced Operation Control •Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Overload Protector •2-Stage OLP to protect the compressor. Overload Protector will trip when – Temperature of compressor increases to 120°C. – High temperature or high current flows to compressor. (Refer circuit diagram for OLP...
Page 6
3 Product Specifications UnitCS-E719KCU-E719K Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz Cooling CapacitykW (BTU/h)2.00 - 2.05 (6,820 - 6,990) Moisture Removall/h (Pint/h)1.3 (2.7) Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)6.0 (210) - 6.0 (210)— Indoor Air (Me)m3/min (cfm)6.7 (240) - 6.7 (240)— Indoor Air (Hi)m3/min (cfm)7.4 (260) - 7.4 (260)30.9 (1,090) - 32.3 (1,140) Noise LeveldB (A)High 35 - 35, Low 26 - 26High 47 - 48 Power level dBHigh 45 -...
Page 7
UnitCS-E719KCU-E719K ThermostatElectronic Control— Protection Device—2 Stage Overload Protector Capillary TubeLengthmm—845 Flow Ratel/min—9.9 Inner Diametermm—1.5 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—20 µF, 400VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC Note: • Specifica tions are subject to change without notice for further improvement. 7 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 8
UnitCS-E919KCU-E919K Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz Cooling CapacitykW (BTU/h)2.65 - 2.70 (9,040 - 9,200) Moisture Removall/h (Pint/h)1.6 (3.4) Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)6.2 (220) - 6.2 (220)— Indoor Air (Me)m3/min (cfm)7.2 (260) - 7.2 (260)— Indoor Air (Hi)m3/min (cfm)8.4 (300) - 8.4 (300)30.9 (1,090) - 32.3 (1,140) Noise LeveldB (A)High 37- 37, Low 26 - 26High 47 - 48 Power level dBHigh 50 - 50High 62 - 63 Electrical...
Page 9
UnitCS-E919KCU-E919K Capillary TubeLengthmm—845 Flow Ratel/min—9.9 Inner Diametermm—1.5 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—30 µF, 400VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC Note: • Specifica tions are subject to change without notice for further improvement. 9 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 10
UnitCS-E1219KCU-E1219K Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz Cooling CapacitykW (BTU/h)3.52 - 3.57 (12,000 - 12,200) Moisture Removall/h (Pint/h)2.1 (4.4) Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)7.6 (270) - 7.6 (270)— Indoor Air (Me)m3/min (cfm)8.7 (310) - 8.7 (310)— Indoor Air (Hi)m3/min (cfm)10.2 (360) - 10.2 (360)30.9 (1,090) - 32.3 (1,140) Noise LeveldB (A)High 40 - 40, Low 29 - 29High 49 - 50 Power level dBHigh 53 - 53High 63 - 64...