Page 51
1. The Electronic Controller, a Signal Receiver and an Indicator (Fig. 3) can be seen by the below steps: • Remove the 2 caps and 2 screws at the bottom of the Front Grille. (Fig. 1) • Remove the Front Grille by releasin g the 2 hooks at the top of the Front Grille. (Fig. 1) • Remove the Control Board Cover by releasin g the 2 tabs at left, 1 tab on top and 1 tab at right side of the Control Board Cover. (Fig. 2) 2. To remove the Electronic Controller: • Release the Particular Piece. (Fig. 3) •...
Page 52
− Pulling out the Drain Hose from outlet to remove the Discharge Grille. (Fig. 5) − Removing the right and left screws. (Fig. 5) − Then remove the Control Board by pressing down the hook at the left and pushing up the right hook. (Fig. 5) − Release the Fan Motor leadwire by pressing the hook at the center of the connector. (Fig. 6) − Remove the screw at the Cross Flow Fan. (Fig. 7) − REMINDER - To reinstall the Fan Motor, adjust the connector of the Fan Motor as shown in the Fig. 7. Fig. 5 Fig. 6...
Page 53
− Remove the screws at the left of the Evaporator. (Fig. 8) − Remove the Bearing. (Fig. 9) − Push up the Evaporator and pull out the Cross Flow Fan from shaft. By then, Fan Motor can be taken out. (Fig. 9) Fig. 8 Fig. 9 53 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 54
• Remote Control Reset When thebatteries are inserted for the first time, or the batteries are replaced, all the indications will blink and the remote control might not work. If this happen , you will find a resetting terminal, and by shorting it with a minus screwdriver, it will return to normal. • Changing the wireless remote control transmission code When twoindoor units are installed in the same room, in order to prevent operating errors caused by using two remote controls, cut a jumper wire at the...
Page 55
13.1. Refrigeration cycle system In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insuffic ient insulation, problem with the power source, malfunction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depend s on various conditio ns, the standard values for them are shown in the table to the right. 13 Troubleshooting Guide 55 CS-E719K CU-E7 19K / CS-E919K...
Page 56
13.1.1. Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Condition of the air conditonerLow PressureHigh PressureElectric current during operation Insufficient refrigerant (gas leakage) Clogged capillary tube or Strainer Short circuit in the indoor unit Heat radiation deficiency of the outdoor unit Inefficient compression • Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started....
Page 59
15 Exploded View Note: The above explode d view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 59 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 60
16 Replacement Parts List REF. NO.PART NAME & DESCRIPTIONQTY.CS-E719KCS-E919KCS-E1219KREMARKS1CHASSY COMPLETE1CWD50C1240←←2FAN MOTOR1CWA921181←←03CROSS FLOW FAN COMPLETE1CWH02C1012←←4BEARING ASS’Y1CWH64K007←←5SCREW - CROSS FLOW FAN1CWH4580304←←6EVAPORATOR1CWB30C1233←CWB30C12377FLARE NUT1CWH6002140(1/4”)←←8FLARE NUT1CWT25005 (3/8”)←CWT25007 (1/2”)9INTAKE AIR SENSOR HOLDER1CWH32142←←10DISCHARGE GRILLE COMPLETE1CWE20C2101←←11VERTICAL VANE12CWE241068←←12CONNECTING BAR2CWE261024←←13AIR SWING...