Page 21
Soft Dry Operation Time Diagram Quiet Operation Control (For Dry region of Soft Dry Mode) 21 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 22
Air Circulation Mode Operation Time Diagram Standard for Determining Operation Mode 8.3. Air Circulation Mode Operation • W hen the temperature near the ceiling reaches the setting temperature, Air Circulation Mode operationcommences at low airflow volume. It stops when the temperature drops to 2°C below the setting temperature. 8.4. Automatic Mode Operation • Indoor fan operates at SLo fan speed for 20 seconds. • After judging indoor air temperature, the operation mode is determined and operation...
Page 23
8.5. Powerful Mode Operation • Purpose of this operation is to obtain the setting temperature quickly. • W hen the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting temperature (Lower temperature: 16°C). • This operation automatically will be running under SHi Fan Speed (Cooling), Lo- Fan Speed (Soft Dry). • Vertical Airflow Direction:- -In“Manual”setting, the vane will automatically shift down 10°lower than previous setting. -In“Auto”setting,...
Page 24
8.8. Indoor Fan Speed Control • Auto Fan Speed Control When set toAuto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. • Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote control. 24 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 25
Vertical Airflow Direction Auto-Control • W hen set a Airflow Direction Auto-Control with remote control, the louver swings up and down as shown in the diagram. • The louver does not swing when the Indoor Fan Motor stops during operation at the upper limit. • W hen stopped with remote control, the discharge vent is reset, and stopped at the closing position . Vertical Airflow Direction manual Control • W hen the manual Airflow Direction Selection Button is pressed, the automatic airflow is released...
Page 26
9 Operating Instructions Outdoor Unit Remote Control • Remote control signal, maximum distance: 10m • Some fluorescent lamps may interfere signal transmission Air intake Air outlet Piping, connecting cable Air outlet Automatic operation* steps: 2-press to START » 3-press again to STOP » *if Remote Control is malfunction / misplaced 1-open front panel Front panel 28 28 29 29 29 29 29 Memory reset!Activate «QUIET» Select FAN SPEED TIMER functionsPOWER OFF/ON Set TEMPERATURE +/– Activate «POWERFUL /...
Page 27
POWERFUL /ECONOMYQUIET Preparations Indoor Unit Plug in Installation: see enclosed installation instruction! HELPFUL INFORMATION Save cost! TEMP warmer! Close! Clean!Upon power resume...RESTART automatically 3-4 Min. –> - MODE - AIRFLOW directionRestored! UnuseBetter performance! Insert batteries Same type! Rechargeable Open / remove Insert batteries / close Batteries check –> see page 26Automatic Operation If Remote Control is malfunction / misplaced Thunder / Lightning Built in surge protection BUT...
Page 28
Additional comfort! set temperature set temperature According to the room temperature the system automatically chooses COOL or SOFT DRY Cooling Cooling down for your comfort. Set your temperature Dehumidifying Very gently cooling. Fan - low speed below set temperature Ambient, circulated Air circulation. Fan speed depending from room temperature Indoor tempStandard temp Press button! MULAI / HENTI 28 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 29
QUIET Operation OFFOFF 1 hr eg. Delay hr Delay Timer Air-Cond. (1 hr) ONON 6 hrs (6 hrs) OFFOFFONON3 hrs — OFF 4 hrs — ON (3 hrs)(4 hrs)OFFOFFONON6 hrs — ON 2 hrs — OFF (6 hrs)(2 hrs) FA N FA N Direction horizontal Delay ON timer Delay OFF timer Delay ON and OFF Timer Delay OFF and ON Timer set Delay hour (1~12)confirm or ApplicationsIf start 15 min. before «ON» time for your comfort. adjust manually Direction vertical Fan speed (air volume) Operational details Start 15 min. Timer operation will activate...
Page 30
cooler or more CARE & CLEANING Indoor Unit / Remote Control Soft Front Panel Soaps Household detergents Benzene / Thinne Scouring powder Wipe gently! .... + dry Pre-season inspections Remove / clean Air filters 2 weeksAir Filter.... dry Reinstall damaged –> replace! Par t No. CWD001047 «FRONT» Filters For extended non-operation OFF Consult an authorized distributor for inspection! Recommended InspectionsAfter several seasons and due to operational conditions, the performance may be reduced by dir t or...