Page 11
UnitCS-E1219KCU-E1219K Capillary TubeLengthmm605 Flow Ratel/min—15.7 Inner Diametermm—1.7 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—30 µF, 400VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC Note: • Specifica tions are subject to change without notice for further improvement. 11 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 14
5 Refrigeration Cycle Diagram 14 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 17
Cooling in operation according to Remote Control setting. Time DelaySafety Control (3 minutes) 7 minutes TimeSave Control Starting Current Control Anti-Freezing Control • If the temperature of the indoor heat exchan ger falls continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan speed setting remains the same. • Compressor will restart again when the indoor heat exchanger temperature rises to 10°C (Recovery). 3 minutes waiting...
Page 18
Automatic Fan Speed Mode Cooling Operation Time Diagram WhenAutomatic Fan Speed is selected at Remote Control during cooling operation. • Fan speed rotates in the range of Hi to Me. 18 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Page 19
Quiet Operation Control (For Cooling Mode or cooling region of Soft Dry Mode) • Purpose of this operation is to provide quite cooling operation compare to normal operation. • W hen the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased 2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation. • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control. • Dew formation become severe at Quiet Lo cool,...
Page 20
Time DelaySafety Control Starting Current Control Anti-Freezing Control Compressor Reverse Rotation Protection Control Automatic Fan Speed Mode 8.2. Soft Dry Mode Operation • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start. • During Soft Dry operation, the Indoor Fan will operate at Lo- speed. • The operation will be switched on and off for up to 10 minutes“ON”and 6 minutes“OFF”. Once Soft...